Por favor, use este identificador para citar o enlazar este ítem:
http://dspace.espoch.edu.ec/handle/123456789/9447
Registro completo de metadatos
Campo DC | Valor | Lengua/Idioma |
---|---|---|
dc.contributor.advisor | Álvarez Pacheco, Carlos Oswaldo | - |
dc.contributor.author | Toainga Toapanta, Ana Mariela | - |
dc.date.accessioned | 2019-02-05T22:12:16Z | - |
dc.date.available | 2019-02-05T22:12:16Z | - |
dc.date.issued | 2018-02-08 | - |
dc.identifier.citation | Toainga Toapanta Ana Mariela. (2018). Diseño de un plan de emergencia y contingencia según la Norma NFPA 2010 en la empresa Metálicas Pillapa del cantón Pelileo. Escuela Superior Politécnica de Chimborazo. Riobamba. | es_ES |
dc.identifier.uri | http://dspace.espoch.edu.ec/handle/123456789/9447 | - |
dc.description | El objetivo principal del presente trabajo de titulación es diseñar un Plan de Emergencia y Contingencia en la empresa Metálicas Pillapa del Cantón Pelileo. Para cumplir tal objetivo, se aplica la siguiente metodología: primero, analizar la situación actual de la empresa; segundo, evaluar el riesgo de incendio; tercero, elaborar el plan de emergencia, evacuación y contingencia; cuarto, realizar un simulacro para evaluar la eficiencia del plan. El diagnóstico de la situación actual se realiza mediante la aplicación de técnicas de recolección de datos como: observación, entrevista y cuestionarios; el riesgo de incendio se evalúa por el método de Meseri; el plan de emergencia se realiza en base a lo establecido por la Secretaría de Gestión de Riesgos y la normativa NFPA; la eficiencia del plan se determina mediante un cuestionario de evaluación del simulacro. En cuanto a los resultados de evaluación se obtuvo: coeficiente de protección de incendio igual a 2,5; tiempo de evacuación igual a 1,5 minutos; puntaje de eficiencia del simulacro igual a 126/126. En conclusión se determinó que la carga de fuego de Metálicas Pillapa es de baja propagación y baja potencia sin embargo en cuanto a parámetros del método Meseri se considera grave y no aceptable por lo tanto Metálicas Pillapa debe implementar el plan de emergencia. Finalmente se recomienda, actualizar periódicamente el plan de emergencia según las vulnerabilidades que se presenten a futuro en la empresa. | es_ES |
dc.description.abstract | The main objective of the present work of qualification is to design an emergency and contingency Plan in the metal company Pillapa of the Canton Pelileo. To meet the objective, the following methodology is applied: first, the current situation of the company is analyzed; second, the risk of fire is assessed; third, the emergency, evacuation and contingency plan is drawn up; fourth, a drill is performed to evaluate the plan`s efficiency. Data collection techniques such as observation, interview and questionnaires are applied to the current situation analysis; the risk of fire is assessed by the Meseri method; the emergency plan is based on the provisions of the Secretary of Risk management and NFPA regulations; the efficiency of the plan is determined by a mock assessment questionnaire. The results of the evaluation were obtained: fire protection coefficient equal to 2,5; evacuation time equal to 1,5 minutes; Simulation efficiency score equal to 126/126. In conclusion it was determined that the fire load of metallic Pillapa is of low propagation and low power, however in terms of parameters of the method Meseri is considered serious and not acceptable therefore metallic Pillapa must implement the plan of emergency. Finally, it is recommended; periodically update the emergency plan according to the vulnerabilities that are presented to the future in the company | es_ES |
dc.language.iso | spa | es_ES |
dc.publisher | Escuela Superior Politécnica de Chimborazo | es_ES |
dc.relation.ispartofseries | UDCTFM;85T00492 | - |
dc.rights | Info:eu-repo/semantics/openAccess | es_ES |
dc.subject | TECNOLOGÍA Y CIENCIAS DE LA INGENIERÍA | es_ES |
dc.subject | PLAN DE EMERGENCIA | es_ES |
dc.subject | EVACUACIÓN | es_ES |
dc.subject | EVALUACION DE INCENDIO | es_ES |
dc.subject | SIMULACRO | es_ES |
dc.subject | AMENAZA | es_ES |
dc.subject | VULNERABILIDAD | es_ES |
dc.title | Diseño de un plan de emergencia y contingencia según la Norma NFPA 2010 en la empresa Metálicas Pillapa del cantón Pelileo. | es_ES |
dc.type | bachelorThesis | es_ES |
dc.contributor.miembrotribunal | Cayán Martínez, Juan Carlos | - |
dc.rights.uri | https://creativecommons.org/licenses/by-nc-sa/3.0/ec/ | es_ES |
Aparece en las colecciones: | Ingeniero Industrial |
Ficheros en este ítem:
Fichero | Descripción | Tamaño | Formato | |
---|---|---|---|---|
85T00492.pdf | 1,27 MB | Adobe PDF | Visualizar/Abrir |
Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons