dc.identifier.citationQuisintuña Jinde, Alejandra Karolina. (2017). Mantenimiento mejorativo del sistema eléctrico domiciliario e industrial en las instalaciones de la piscina de la Escuela Superior Politécnica de Chimborazo mediante el estudio de eficiencia energética. Escuela Superior Politécnica de Chimborazo. Riobamba.es_ES
dc.identifier.urihttp://dspace.espoch.edu.ec/handle/123456789/7565-
dc.descriptionEl presente trabajo de titulación describe el mantenimiento mejorativo del sistema eléctrico domiciliario e industrial en las instalaciones de la piscina de la Escuela Superior Politécnica de Chimborazo mediante el estudio de eficiencia energética, que tuvo como objetivo el desarrollo de un estudio de eficiencia energética de las mismas, identificando puntos calientes que son provocados por incrementos de corriente, una inadecuada selección de conductores, elementos mal ajustados, corrosión y suciedad. Este proyecto en su desarrollo contiene conceptos teóricos de mantenimiento, eficiencia energética en instalaciones deportivas, conceptos generales del equipo termográfico FLIR SERIE E, evaluación de severidad y generación de informes del estado de los elementos de las instalaciones con lo cual se realiza el mantenimiento mejorativo reemplazando elementos eléctricos en mal estado que provocan el calentamiento de los conductores y demás elementos eléctricos. Con el mantenimiento mejorativo en las instalaciones de la piscina de la ESPOCH que comprende la utilización de cables, protecciones, y demás dispositivos con un calibre adecuado de acuerdo a la norma UNE-EN 60617 se optimiza el servicio en las instalaciones generando ahorro energético y mejora la estética de las mismas. Con la implementación del estudio en las instalaciones de la piscina se incrementa la eficiencia y rendimiento de la misma, además de conservar los activos logrando alcanzar su vida útil y garantizando su funcionamiento evitando fallos en los sistemas. Al mismo tiempo rehabilitar la malla a tierra existente en el área del cuarto de máquinas de la piscina es importante ya que su ausencia representa un riesgo tanto para los equipos como para el personal que labora en el lugar.es_ES
dc.description.abstractThe present graduation work describes the enhancement maintenance of the electronic system domiciliary and industrial in the facilities of the swimming pool of thr Polytechnic School of Chimborazo by means of the study of energy efficiency, whose objective was the development of a study of the energy efficiency of the same, identifying hot spots that are caused by power increases, improper selection of conductors, maladjusted elements, corrosion and dirt. This project in its development contains theoretical concepts of maintenance, energy efficiency in sports facilities, general concepts of the thermal equipment FLIR SERIE E, evaluation of severity and generation of reports of the states of the elements of the facilities with which the enhancement maintenance is done replacing electrical element in poor condition that cause the heating of conductors and other electrical elements. With the enhancement maintenance in ESPOCH pool facilities that includes the use of cables, protections, and other devices with a suitable gauge in accordance with the UNE –EN 60617 standard the service in the facilities is optimized generating energy savings and better aesthetics of them. With the implementation of the study in the pool facilities, the efficiency and performance of the pool is increased, as well as preserving the assets achieving their useful life and guaranteeing their operation avoiding system failures. At the same time, rehabilitating the existing ground mesh in the area of the pool machine room is important since its absence represents a risk for both the equipment and the staff working on the place.es_ES
dc.language.isospaes_ES
dc.publisherEscuela Superior Politécnica de Chimborazoes_ES
dc.relation.ispartofseriesUDFM;25T00313-
dc.subjectSITEMAS ELÉCTRICOSes_ES
dc.subjectEFICIENCIA ENERGÉTICAes_ES
dc.subjectSELECCIÓN DE CONDUCTORESes_ES
dc.subjectMANTENIMIENTO MEJORATIVOes_ES
dc.subjectANÁLISIS TERMOGRÁFICOes_ES
dc.subjectPUNTOS CALIENTESes_ES
dc.titleMantenimiento mejorativo del sistema eléctrico domiciliario e industrial en las instalaciones de la piscina de la Escuela Superior Politécnica de Chimborazo mediante el estudio de eficiencia energética.es_ES
dc.typebachelorThesises_ES
dc.contributor.miembrotribunalSantillán Gallegos, Marco Heriberto-
Aparece en las colecciones: Ingeniero de Mantenimiento; Ingeniero/a en Mantenimiento Industrial

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
25T00313.pdf2,8 MBAdobe PDFVista previa
Visualizar/Abrir


Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.