Por favor, use este identificador para citar o enlazar este ítem: http://dspace.espoch.edu.ec/handle/123456789/6978
Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.contributor.advisorViteri Núñez, Edwin Fernando-
dc.contributor.authorNachimba Sánchez, Nelson Israel-
dc.contributor.authorPeña Pérez, Hugo Javier-
dc.date.accessioned2017-08-08T17:27:45Z-
dc.date.available2017-08-08T17:27:45Z-
dc.date.issued2017-
dc.identifier.citationNachimba Sánchez, Nelson Israel; Peña Pérez, Hugo Javier. (2017). Diagnóstico energético en el Hotel SPA Termal Monte Selva del Cantón Baños Provincia de Tungurahua bajo la norma ISO 50001. Escuela Superior Politécnica de Chimborazo. Riobamba.es_ES
dc.identifier.urihttp://dspace.espoch.edu.ec/handle/123456789/6978-
dc.descriptionEl consumo excesivo de recursos energéticos y la problemática medio ambiental motivaron realizar un diagnóstico energético en los sistemas de área húmeda y de iluminación en el Hotel Spa Termal Monte Selva aplicando la norma NTE INEN ISO 50001:2012 (Sistema de Gestión de la Energía). El desarrollo del proyecto tiene como alcance identificar y proponer las alternativas técnicas, económicas más viables para el mejoramiento operacional y aprovechamiento de recursos energéticos; esto implicó la recopilación de datos históricos del consumo energético de los equipos del Hotel en un periodo de tres años previos al diagnóstico. Posteriormente se realizó el análisis global del consumo energético y se clasificó a la organización por áreas; con los diagramas de Pareto se identificaron los equipos críticos por orden de importancia a los problemas presentes en los procesos. Así también se utilizó la norma ASME PTC 4.0:2008 (Código de Pruebas para el Rendimientos de Generadores de Vapor); como el procedimiento para determinar la eficiencia de la caldera en base a los dos métodos planteados; método directo (Input output method) y el método indirecto (Energy balance method). Para el método indirecto y para determinar las pérdidas de calor en la distribución de vapor a los usos finales, se aplicó el software ENGINEERING ECUATION SOLVER (EES), éste facilitó las propiedades termodinámicas del agua y del aire. Posteriormente se determinó los rendimientos de las bombas; conociendo las características de las tuberías y accesorios de los sistemas en operación. Por último se determinó el índice de eficiencia energética (EEI) del sistema de luminarias obteniendo resultados que cumplen con la norma NTE INEN 1152:84 (Iluminación natural en edificios). En conclusión se evidenció que los equipos no están trabajando en óptimas condiciones, el mayor problema se da por no cumplir estándares mínimos de calidad (construcción de equipos bajo normas) y asesoría técnica calificada. La participación activa del personal calificado y la posible incorporación de las mejoras adoptadas, que tiene una recuperación de hasta un mínimo de 30% en el presente estudio, garantizarán la mejora en el desempeño energético.es_ES
dc.description.abstractThe excessive consumption of energetic resources and the environmental problem motivated carryng out an energetic diagnosis un the humid area and ilumination systems in the Hotel Spa Termal Monte Selva applying the NTE INEN ISO 50001:2012 norm (Energy Management System). The project development deals with identifying and proposing the mores viable and economic technical and economic alternatives for the operational improvement and use of energetic resources; this implied the historical data collection of energetic consumption of the hotel equipment in a three-year period previous to the diagnosis. Later, the global analysis of the energetic consumption was carried out and the organization was classified by areas; with the Pareto diagrams the critical equipment as well as the problems present in the processes by importance order were identified. Also the ASME PTC 4.0:2008 norm (Testing Code for the Performance of Steam Generators) was used as the procedure to determine the boiler efficiency on the basis of the two stated methods: direct method (imput-utput method) and the indirect method (energy balance method). For the indirect method and to determine the heat losses in the steam distribution to the final uses, the software ENGINEERING EQUATION SOLVER (EES) was applied; this facilitated the water and air thermodynamic properties. Later, the pump yield was determined, knowing the piping and the accessory features of the systems in operation. Finally, the energetic, the energetic efficiency index (EEI) of the luminary systems was determined obtaining results which accomplish the NTE INEN 1152:84 norm (Natural illumination in Buildings). As a conclusion, it was evident that the equipment is not working in optimum conditions, the mayor problem is given for not accomplishing minimum quality standards (equipment construction under norms) and qualified technical advice. The active participation of the qualified personnel and the possible incorporation of the adopted improvements which have a recuperation of up to a minimum of 30% in the present study will guarantee the improvement in the energy performance.es_ES
dc.language.isospaes_ES
dc.publisherEscuela Superior Politécnica de Chimborazoes_ES
dc.relation.ispartofseriesUDFM;15T00667-
dc.subjectDIAGNÓSTICO ENERGÉTICOes_ES
dc.subjectEFICIENCIA ENERGÉTICAes_ES
dc.subjectPERFORMANCE TEST CODE (ASME PTC4.0:2008)es_ES
dc.subjectCULTURA ENERGÉTICAes_ES
dc.subjectTECNOLOGÍA GLOBAL DE ENERGÍA AMBIENTAL (GEET)es_ES
dc.titleDiagnóstico energético en el Hotel SPA Termal Monte Selva del Cantón Baños Provincia de Tungurahua bajo la norma ISO 50001.es_ES
dc.typebachelorThesises_ES
dc.contributor.miembrotribunalChuquin Vasco, Nelson Santiago-
Aparece en las colecciones: Ingeniero/a Mecánico/a

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
15T00667.pdf7,53 MBAdobe PDFVista previa
Visualizar/Abrir


Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.