dc.identifier.citation | Totoy Pilco, Edwin Marcelo; Moreta Ramírez, Melinton Ademar. (2016). Diseño e implementación de una planta (prototipo) de tratamiento de agua potable tipo paquete para los pozos uno y dos de la Escuela Superior Politécnica de Chimborazo. Escuela Superior Politécnica de Chimborazo. Riobamba. | es_ES |
dc.identifier.uri | http://dspace.espoch.edu.ec/handle/123456789/6206 | - |
dc.description | Se diseñó una planta de potabilización a partir de aguas subterráneas, para la Escuela Superior Politécnica de Chimborazo de los pozos 1 y 2. Se inició el análisis del agua en base a la caracterización físico-química y microbiológica, utilizando los métodos establecidos en el Manual Estándar Methods para control de calidad del agua y el espectrofotómetro HACH DR 2800 y 2400. El proceso experimental de potabilización se llevó a cabo en una planta prototipo, en el que se efectuó, la filtración con resina catiónica, que aumenta su eficiencia y tiempo de vida al activarla con 10 mL de solución de cloruro de sodio al 10%, durante 20 min. y luego el lavado por 15 min., disminuyendo la dureza con el 65,59 % de eficiencia y un mayor tiempo de vida. Luego la cloración en el que se determinó que con dos gotas de cloro (0,1 mL de NaClO al 10%), se obtenía después de 30 minutos de acción, una cantidad de cloro residual de 0,55 ppm, demostrando de esta manera que la concentración de microorganismos fue destruida y aún quedaba 0,55 ppm de cloro. En conclusión se determinó que el agua de la ESPOCH no es apta para el consumo humano, pues tiene un alto índice de dureza de 558 mg /L. Mediante el proceso de ablandamiento utilizando filtros con resina catiónica se disminuyó la concentración de Ca y Mg a 192,0 mg/L teniendo una remoción total media del 65,59 %, controlando el parámetro de la dureza, dando como resultado una agua apta para el consumo de acuerdo a la Norma NTE INEN 1108 2006 y su reforma INEN 1108 2011. Se recomienda aplicar este sistema de tratamiento para el mejor abastecimiento de agua y salubridad, los parámetros de dureza, alcalinidad y fluoruros son muy delicados, por lo que se debe llevar un control continuo del proceso. | es_ES |
dc.description.abstract | It was designed a groundwater treatment plant to the Polytechnic School of Chimborazo from 1 and 2 wells. It began the analysis of water based on the physical-chemical and microbiological characterization, using the methods set out in the Standard Manual Methods for quality control of water and the spectrophotometer HACH DR 2800 and 2400. The experimental process of purification was carried out on a prototype plant, in which was carried out, the filtration with cationic resin, which increases its efficiency and time of life when it activates with 10 ml of sodium chloride solution to 10%, for 20 minutes and then the washing for 15 min., decreasing the hardness with the 65, 59 % of efficiency and a greater time of life. Then the chlorination where it was found that with two drops of chlorine (0.1 mL of born to 10%) was obtained after 30 minutes of action , an amount of residual chlorine of 0.55 ppm, establishing that in this way the concentration of microorganisms was destroyed and it remained 0.55 ppm of chlorine. In conclusion it was determined that the water from ESPOCH is unfit for human consumption, because it has a high rate of hardness of 558mg/L. So, through the process of softening using filters with cationic resin decreased the concentration of Ca and Mg to 192, 0 mg/L, taking a total removal average of 65, 59% controlling the parameter of the hardness, giving as a result a suitable water for consumption according to the Standard NTE INEN 1108 2006 and its reform INEN 1108 2011. It is recommended to apply this treatment system to improved water supply and sanitation, parameters of hardness, alkalinity and fluorides are very sensitive, so it must carry a continuous control of the process. | es_ES |
dc.language.iso | spa | es_ES |
dc.publisher | Escuela Superior Politécnica de Chimborazo | es_ES |
dc.relation.ispartofseries | UDCTFC;236T0228 | - |
dc.subject | BIOTECNOLOGÍA | es_ES |
dc.subject | DISEÑO DE PLANTA DE TRATAMIENTO | es_ES |
dc.subject | PROCESOS DE POTABILIZACIÓN | es_ES |
dc.subject | AGUA SUBTERRÁNEA | es_ES |
dc.subject | CARACTERIZACIÓN FÍSICO-QUÍMICA Y MICROBIOLÓGICA | es_ES |
dc.subject | RESINA CATIÓNICA | es_ES |
dc.title | Diseño e implementación de una planta (prototipo) de tratamiento de agua potable tipo paquete para los pozos uno y dos de la Escuela Superior Politécnica de Chimborazo. | es_ES |
dc.type | bachelorThesis | es_ES |
dc.contributor.miembrotribunal | Carrera Beltrán, Lourdes Cumandá | - |
Aparece en las colecciones: | Ingeniero/a en Biotecnología Ambiental; Ingeniero/a Ambiental |
Ficheros en este ítem:
Fichero | Descripción | Tamaño | Formato | |
---|---|---|---|---|
236T0228.pdf | 3,96 MB | Adobe PDF | Visualizar/Abrir |
Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.