Por favor, use este identificador para citar o enlazar este ítem:
http://dspace.espoch.edu.ec/handle/123456789/3227
Registro completo de metadatos
Campo DC | Valor | Lengua/Idioma |
---|---|---|
dc.contributor.advisor | Brito Moina, Hannibal Lorenzo | - |
dc.contributor.author | Pancho Acosta, Fernando Gustavo | - |
dc.date.accessioned | 2014-03-05T15:10:47Z | - |
dc.date.available | 2014-03-05T15:10:47Z | - |
dc.date.issued | 2014-03-05T15:10:47Z | - |
dc.identifier.citation | Pancho Acosta, Fernando Gustavo. (2014). Diseño de un sistema de calidad en el Laboratorio de Análisis de Agua en el Municipio del cantón Guano. Escuela Superior Politécnica de Chimborazo. Riobamba. | es_ES |
dc.identifier.uri | http://dspace.espoch.edu.ec/handle/123456789/3227 | - |
dc.description | Diseñar un sistema de calidad en el laboratorio de análisis de agua potable en el cantón Guano. La metodología para el desarrollo del presente trabajo es deductivo e inductivo, a partir de la norma NTE ISO/IEC 17025, se realizó el diagnostico actual del laboratorio municipal. Se estudió las actividades con relación al enfoque de la calidad de la Norma 17025, con el propósito de determinar conclusiones y recomendaciones generales que beneficien al Laboratorio. Además el diseño no es experimental sino descriptivo. Se realizó los análisis fisicoquímicos y microbiológicos de agua potable donde el muestreo fue al azar de cada una de las redes de distribución. Los métodos utilizados fueron potenciométricos y colorimétricos, los equipos utilizados fueron el pH metro, el espectrofotómetro, turbidímetro. Realizado el diagnostico actual del laboratorio se encuentra con menos del 50% dentro de los parámetros del Sistema de Gestión de Calidad. El diseño realizado supero un 70% de los parámetros de calidad. La inspección sanitaria realizada a los tanques de distribución presenta menos del 50% de lo requerido de acuerdo a los parámetros de saneamiento. El agua que abastece se encuentra por debajo de los límites permisibles solicitada por la INEN 1108. Con el diseño realizado se mejorara la calidad de los resultados de los análisis del agua y se realizara las medidas correctivas en los tanques de distribución. El agua del cantón Guano no es apta para el consumo. Se recomienda realizar la implementación del diseño y la dosificación de cloro para la desinfección del agua. | es_ES |
dc.description.abstract | To design a quality system for the drinking water analysis laboratory in Guano county. The methodology for the development of this work is deductive and inductive, based on the NTE ISO/IEC 17025 standard, the current diagnosis of the municipal laboratory was carried out. The activities were studied in relation to the quality approach of Standard 17025, with the purpose of determining conclusions and general recommendations that benefit the laboratory. In addition, the design is not experimental but descriptive. The physicochemical and microbiological analyses of drinking water were carried out with random sampling from each of the distribution networks. The methods used were potentiometric and colorimetric, the equipment used was the pH meter, spectrophotometer and turbidimeter. The current diagnosis of the laboratory is less than 50% within the parameters of the Quality Management System. The design performed exceeded 70% of the quality parameters. The sanitary inspection of the distribution tanks shows less than 50% of what is required according to sanitation parameters. The water supply is below the permissible limits required by INEN 1108. The design will improve the quality of the water analysis results and corrective measures will be taken in the distribution tanks. The water in Guano is not fit for consumption. It is recommended that the design and dosage of chlorine for water disinfection be implemented. | es_ES |
dc.language.iso | spa | es_ES |
dc.publisher | Escuela Superior Politécnica de Chimborazo | es_ES |
dc.relation.ispartofseries | UDCTFC;56T00404 | - |
dc.rights | info:eu-repo/semantics/openAccess | es_ES |
dc.subject | AGUA POTABLE | es_ES |
dc.subject | ANÁLISIS DE AGUAS | es_ES |
dc.subject | CONTROL DE LA CALIDAD | es_ES |
dc.subject | DISEÑO DE SISTEMAS DE CALIDAD | es_ES |
dc.subject | MUNICIPIO CANTÓN GUANO | es_ES |
dc.title | Diseño de un sistema de calidad en el Laboratorio de Análisis de Agua en el Municipio del cantón Guano | es_ES |
dc.type | bachelorThesis | es_ES |
dc.contributor.miembrotribunal | Cazar Ramírez, Robert Alcides | - |
dc.rights.uri | https://creativecommons.org/licenses/by-nc-sa/3.0/ec/ | es_ES |
Aparece en las colecciones: | Bioquímico/a y Farmacéutico/a |
Ficheros en este ítem:
Fichero | Descripción | Tamaño | Formato | |
---|---|---|---|---|
56T00404.pdf | 4,64 MB | Adobe PDF | Visualizar/Abrir |
Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons