Por favor, use este identificador para citar o enlazar este ítem: http://dspace.espoch.edu.ec/handle/123456789/21973
Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.contributor.advisorIsa Jara, Ramiro Fernando-
dc.contributor.authorIdrovo Cando, Bryan Alexander-
dc.contributor.authorCarreño Taxi, Michael Andres-
dc.date.accessioned2024-07-01T18:45:37Z-
dc.date.available2024-07-01T18:45:37Z-
dc.date.issued2024-04-09-
dc.identifier.citationIdrovo Cando, Bryan Alexander; Carreño Taxi, Michael Andres. (2024). Desarrollo de una prótesis mioeléctrica móvil para transferencia de calor en pacientes con amputaciones transradial para el grupo de investigación IDIPM-001. Escuela Superior Politécnica de Chimborazo. Riobamba.es_ES
dc.identifier.urihttp://dspace.espoch.edu.ec/handle/123456789/21973-
dc.descriptionEl presente trabajo tuvo como finalidad el desarrollo de una prótesis mioeléctrica móvil de bajo costo con la integración de un sistema electrónico para transferencia de calor entre dispositivos externos y pacientes con amputaciones transradiales. El proceso de desarrollo inició con la digitalización tanto de la extremidad no afectada como de la amputación utilizando tecnología de escaneo 3D. Para el diseño del prototipo se utilizó el software Meshmixer y FUSION 360. La fabricación de los elementos de la prótesis se realizó mediante impresión 3D, empleando una combinación de materiales como PLA y TPU para lograr la resistencia y flexibilidad adecuada en su uso. El circuito electrónico se compuso principalmente de tres servomotores, dos sensores de temperatura SHT25, un sensor Myoware, un microcontrolador Arduino Nano, un Micro Servocontrolador (Polulo), un regulador de voltaje, batería de 450 mAh y un circuito diseñado para controlar la temperatura de la Celda Peltier. Estos componentes fueron distribuidos estratégicamente en la prótesis utilizando el espacio disponible entre la mano, brazo y muñón. La programación realizada en Maestro Control Center incluyó una fase de calibración de señales musculares del paciente para detectar y responder a los estímulos musculares. Además, el Arduino Nano permitió controlar la temperatura de la prótesis utilizando la Celda Peltier para salvaguardar la integridad del paciente y del dispositivo. Mediante el análisis estadístico se obtuvo una latencia promedio de 250.7 milisegundos y un margen de error porcentual de 1.23% en la medición de temperatura. El costo total del prototipo se estimó en $837.52, lo cual fue relevante en función de su accesibilidad económica. Las pruebas de funcionamiento se realizaron en un paciente con este tipo de amputación, donde se pudo comprobar que la prótesis fue funcional y óptima para su implementación.es_ES
dc.description.abstractThis work aimed to develop a low-cost mobile myoelectric prosthesis by integrating an electronic system for heat transfer between external devices and patients with trans-radial amputations. The development process began with digitizing the unaffected limb and the amputation using 3D scanning technology. The Meshmixer and FUSION 360 software were used to design the prototype. The prosthesis elements were manufactured using 3D printing, using a combination of materials such as PLA and TPU to achieve adequate resistance and flexibility. The electronic circuit was mainly composed of three servo motors, two SHT25 temperature sensors, a Myoware sensor, an Arduino Nano microcontroller, a Micro Servo Controller (Polulo), a voltage regulator, a 450 mAh battery, and a circuit designed to control the temperature of the Peltier Cell. These components were strategically distributed in the prosthesis using the space between the hand, arm, and stump. The programming carried out in the Maestro Control Center included a calibration phase of the patient's muscle signals to detect and respond to muscle stimuli. In addition, the Arduino Nano allowed the temperature of the prosthesis to be controlled using the Peltier Cell to safeguard the integrity of the patient and the device. Statistical analysis obtained an average latency of 250.7 milliseconds and a percentage margin of error of 1.23% in the temperature measurement. The total cost of the prototype was estimated at $837.52, which was relevant based on its economic accessibility. The functional tests were carried out on a patient with this type of amputation, where it was possible to verify that the prosthesis was functional and optimal for its implementation.es_ES
dc.language.isospaes_ES
dc.publisherEscuela Superior Politécnica de Chimborazoes_ES
dc.relation.ispartofseriesUDCTFIYE;108T0538-
dc.rightsinfo:eu-repo/semantics/openAccesses_ES
dc.subjectDISEÑO CADes_ES
dc.subjectAMPUTACIÓN TRANSRADIALes_ES
dc.subjectLATENCIAes_ES
dc.subjectFABRICACIÓN ADITIVAes_ES
dc.subjectCELDA PELTIERes_ES
dc.subjectACTIVACIÓN MUSCULAes_ES
dc.subjectBIOMEDes_ES
dc.subjectPRÓTESIS MIOELÉCTRICAes_ES
dc.titleDesarrollo de una prótesis mioeléctrica móvil para transferencia de calor en pacientes con amputaciones transradial para el grupo de investigación IDIPM-001.es_ES
dc.typeinfo:eu-repo/semantics/bachelorThesises_ES
dc.contributor.miembrotribunalPacheco Cunduri, Mayra Alejandra-
dc.rights.urihttps://creativecommons.org/licenses/by-nc-sa/3.0/ec/es_ES
Aparece en las colecciones: Ingeniero en Electrónica, Control y Redes Industriales; Ingeniero/a en Electrónica y Automatización

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
108T0538.pdf6,7 MBAdobe PDFVista previa
Visualizar/Abrir


Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons Creative Commons