Por favor, use este identificador para citar o enlazar este ítem: http://dspace.espoch.edu.ec/handle/123456789/20824
Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.contributor.advisorVeloz Chérrez, Diego Fernando-
dc.contributor.authorJácome Coro, Katherine Elizabeth-
dc.date.accessioned2024-04-26T19:00:38Z-
dc.date.available2024-04-26T19:00:38Z-
dc.date.issued2022-07-06-
dc.identifier.citationJácome Coro, Katherine Elizabeth. (2022). Análisis, diseño y construcción de un prototipo bioelectrónico IOT que permita el monitoreo de los niveles de oxígeno, temperatura y ritmo cardíaco. Escuela Superior Politécnica de Chimborazo. Riobamba.es_ES
dc.identifier.urihttp://dspace.espoch.edu.ec/handle/123456789/20824-
dc.descriptionEl objetivo del presente trabajo de integración curricular fue analizar, diseñar y construir un prototipo bioelectrónico IoT que permita el monitoreo de los niveles de oxígeno, temperatura y ritmo cardíaco, se optó por el diseño y la implementación de un prototipo en internet de las cosas, bajo ambientes de dispositivos móviles con Android y páginas Web para la monitorización de datos de temperatura, ritmo cardiaco y nivel de oxígeno a través de los sensores MLX90614 y MAX-30102. Permite tomar datos de los signos vitales de temperatura, ritmo cardiaco y nivel de oxígeno del paciente mediante los sensores y la tarjeta de desarrollo, luego de ello procede a enviar la información a un servidor web almacenándola en una base de datos, por consiguiente, en la aplicación móvil y web se admite el registro del paciente en el sistema y el acceso a los resultados de la información de signos vitales. Para poder determinar el correcto funcionamiento del prototipo bioelectrónico, se realizó la comparación conjunta de la toma de signos de vitales con la ayuda de equipos médicos existentes en el mercado las pruebas se realizaron a 77 pacientes, siendo la muestra utilizada para los cálculos y la comparación de resultados entre los equipos médicos y el prototipo bioelectrónico. Una vez realizada las mediciones y con los datos obtenidos indica que el prototipo bioelectrónico es confiable. Los resultados fueron presentados en la aplicación móvil y web. Se concluye que mediante la aplicación móvil y web es posible mostrar el diagnóstico del paciente conjuntamente con los valores del monitoreo, donde el médico tratante será quien dictamine y valide los signos vitales del paciente. Se recomienda que para el diseño y la implementación de un prototipo de sistema IoT para la monitorización de signos vitales, el uso de distintos sensores para precisar la medición de signos vitales.es_ES
dc.description.abstractThe objective of this curricular integration work was to analyze, design and build an IoT bioelectronic prototype that allows the monitoring of oxygen levels, temperature and heart rate, it was decided to design and implement a prototype in the Internet of things, under environments of mobile devices with Android and Web pages for monitoring data of temperature, heart rate and oxygen level through the MLX90614 and MAX-30102 sensors. It allows taking data of the vital signs of temperature, heart rate and oxygen level of the patient through the sensors and the development card, after which it proceeds to send the information to a web server, storing it in a database, therefore, in mobile and web application support patient registration in the system and access to the results of vital signs information. In order to determine the correct functioning of the bioelectronic prototype, the joint comparison of the taking of vital signs was carried out with the help of existing medical equipment in the market. The tests were carried out on 77 patients, the sample being used for the calculations and the comparison. of results between the medical equipment and the bioelectronic prototype. Once the measurements have been made and with the data obtained, it indicates that the bioelectronic prototype is reliable. The results were presented in the mobile and web application. It is concluded that through the mobile and web application it is possible to show the patient's diagnosis together with the monitoring values, where the treating physician will be the one who dictates and validates the patient's vital signs. It is recommended that for the design and implementation of a prototype IoT system for monitoring vital signs, the use of different sensors to accurately measure vital signs.es_ES
dc.language.isospaes_ES
dc.publisherEscuela Superior Politécnica de Chimborazoes_ES
dc.relation.ispartofseriesUDCTFIYE;98T00368-
dc.rightsinfo:eu-repo/semantics/openAccesses_ES
dc.subjectPROTOTIPO BIOLECTRÓNICOes_ES
dc.subjectINTERNET DE LAS COSAS (IoT)es_ES
dc.subjectMONITORIZACIÓN DE DATOSes_ES
dc.subjectSIGNOS VITALESes_ES
dc.subjectAPLICACIÓN MÓVILes_ES
dc.titleAnálisis, diseño y construcción de un prototipo bioelectrónico IOT que permita el monitoreo de los niveles de oxígeno, temperatura y ritmo cardíaco.es_ES
dc.typeinfo:eu-repo/semantics/bachelorThesises_ES
dc.contributor.miembrotribunalMoreno Montenegro, Franklin Geovanni-
dc.rights.urihttps://creativecommons.org/licenses/by-nc-sa/3.0/ec/es_ES
Aparece en las colecciones: Ingeniero en Electrónica, Telecomunicaciones y Redes; Ingeniero/a en Telecomunicaciones

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
98T00368.pdf3,46 MBAdobe PDFVista previa
Visualizar/Abrir


Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons Creative Commons