Por favor, use este identificador para citar o enlazar este ítem:
http://dspace.espoch.edu.ec/handle/123456789/1888
Registro completo de metadatos
Campo DC | Valor | Lengua/Idioma |
---|---|---|
dc.contributor.advisor | Lema Morales, Jorge Eduardo | - |
dc.contributor.author | Chauca Chicaiza, Alex Fernando | - |
dc.contributor.author | Orozco Cantos, Lenin Santiago | - |
dc.date.accessioned | 2012-06-01T18:39:13Z | - |
dc.date.available | 2012-06-01T18:39:13Z | - |
dc.date.issued | 2012-03-15 | - |
dc.identifier.citation | Chauca Chicaiza, Alex Fernando; Orozco Cantos, Lenin Santiago. (2012). Diseño e Implementación de un Sistema Automatizado para la Dosificación de Cloro en el Tratamiento de Agua Potable en la Comunidad San Vicente de Lacas. Escuela Superior Politécnica de Chimborazo. Riobamba. | es_ES |
dc.identifier.uri | http://dspace.espoch.edu.ec/handle/123456789/1888 | - |
dc.description | Se ha implementado un sistema automático de dosificación de cloro para la comunidad San Vicente de Lacas-Riobamba, donde no se disponía de una adecuada cloración, con la finalidad de asegurar permanentemente la potabilidad del agua. Adicional a esto, se realiza una evaluación del sistema hidráulico que garantice el período de diseño en cuanto a su caudal y dimensiones de tubería. Previo a seleccionar un mecanismo de desinfección eficaz que reemplace el obsoleto sistema original, se realizó un monitoreo de los niveles de cloro residual en las redes del sector por un período de 2 meses, basados en la Norma INEN 1108 y el apoyo del departamento Técnico de EMAPAR. Mientras que el dimensionamiento de las tuberías de conducción de agua, se apega a la Norma CO 10.7-602 del Código ecuatoriano para el diseño de la Construcción de Obras Sanitarias. Con los resultados obtenidos, se evidencia que la alternativa más confiable es la automatización del proceso de cloración. Un sistema capaz de analizar constantemente los niveles de cloro libre con sensores amperométricos y en dependencia de este valor provea la cantidad necesaria de desinfectante a través de una válvula que responde un controlador. El Sistema de Control de lazo cerrado de función proporcional es la opción que mejor se ajusta al comprender el comportamiento que demanda una red de distribución con agua clorada. La parte mecánica del conjunto trabaja con una bomba que impulsa la línea de solución desinfectante, donde se inyecta el cloro gaseoso por la succión generada en un Vénturi, la alimentación del gas proviene de dos cilindros de 68 kg enlazados por una válvula selectora de circuito. En tanto que la evaluación hidráulica demuestra la selección de material y dimensión de la tubería para los diferentes tramos de la conducción. Con la implementación de este sistema se alcanza independencia de un operador para la dosificación, y niveles de cloro libre en las redes de distribución entre 1.1 ppm y 0.5 ppm. Valores aceptados por la Norma INEN 1108. Se recomienda la capacitación adecuada del personal que manipule los equipos dentro de la comunidad, quienes conciban el criterio de salud preventiva con agua de calidad. | es_ES |
dc.description.abstract | An automatic System of Chorine Dosage has been implemented for the San Vicente de Lacas-Riobamba Community where there was not where was not any chlorine provision, to secure permanently the water potability. Moreover a hydraulic system evaluation guaranteeing the design period as to caudal and piping dimensions is carried out. Before selecting and efficient disinfection device replacing the original obsolete system a monitoring of the residual chlorine levels was carried out in the sector network for a period of two months based on the INEN 1108 Norm and the support of the Technical Department of EMAPAR, while the water conduction piping measurements are according to the CO 10.7-602 Norm of the Ecuadorian Code for design of Sanitary Works Construction. With the results it is evident that the most reliable alternative is the chlorine process automation. This is a system capable of constantly analyzing the free chlorine levels with amperometric sensors and based on these values providing the necessary disinfectant quantity through a valve which responds to a controller. The Control System of the close link of proportional function is the best option which fits in with understanding the behavior required by a chlorine water distribution network. The conjunct mechanical part works with a pump which propels the disinfectant solution line where the gas chlorine is injected through suction generated in a Venturi; the gas feeding comes from the 68-kg cylinders liked by a selecting circuit valve. On the other hand the hydraulic evaluation shows the material selection and piping dimension for the different conduction parts. With the implementation of this system independence of an operator is reached of dosage and the free chlorine levels in the distribution network between 1.1 ppm and 0.5 ppm, values accepted by the INEN 1108 Norm. It is recommended to train the personnel handling the equipment within the community who will understand the preventive health with water quality. | es_ES |
dc.language.iso | spa | es_ES |
dc.publisher | Escuela Superior Politécnica de Chimborazo | es_ES |
dc.relation.ispartofseries | UDFM;15T00500 | - |
dc.subject | TRATAMIENTO DE AGUA | es_ES |
dc.subject | SISTEMA AUTOMATIZADO | es_ES |
dc.subject | SISTEMA DE MANTENIMIENTO | es_ES |
dc.subject | SAN VICENTE DE LACAS (COMUNIDAD) | es_ES |
dc.subject | INGENIERÍA SANITARIA | es_ES |
dc.title | Diseño e Implementación de un Sistema Automatizado para la Dosificación de Cloro en el Tratamiento de Agua Potable en la Comunidad San Vicente de Lacas. | es_ES |
dc.type | bachelorThesis | es_ES |
dc.contributor.miembrotribunal | Díaz Bonifaz, Rodrigo | - |
Aparece en las colecciones: | Ingeniero/a Mecánico/a |