dc.contributor.advisorSantillán Gallegos, Marco Heriberto-
dc.contributor.authorAcán Carpintero, Jessica Ximena-
dc.contributor.authorPaucar Iza, Brayan Israel-
dc.date.accessioned2023-05-12T16:56:03Z-
dc.date.available2023-05-12T16:56:03Z-
dc.date.issued2022-12-06-
dc.identifier.citationAcán Carpintero, Jessica Ximena; Paucar Iza, Brayan Israel. (2022). Repotenciación y puesta en funcionamiento del sistema de control domótico para las instalaciones del edificio de la Carrera de Mantenimiento Industrial. Escuela Superior Politécnica de Chimborazo. Riobamba.es_ES
dc.identifier.urihttp://dspace.espoch.edu.ec/handle/123456789/18838-
dc.descriptionEn el modular de la Carrera de Mantenimiento Industrial existía un sistema de control domótico que, debido al tiempo y presencia de averías en los componentes, éste llegó a un estado de deterioro por ende su uso fue suspendido dentro del modular, con la finalidad de ponerlo en funcionamiento se rehabilitó dicho sistema buscando así obtener mejores beneficios en confort, seguridad, comunicación, ahorro energético, etc. Como primer paso se evaluó el nivel de domotización del mismo, tomando en cuenta los tres niveles de domótica establecidos por la Asociación Española de Domótica (CEDOM), nivel 1, nivel 2, nivel 3, reflejando como resultado una edificación con ningún nivel de domotización. Mediante el análisis físico de los elementos sensores y controladores pertenecientes al sistema y gracias a la “metodología de evaluación del estado técnico inicial” se deduce que el sistema domótico preexistente se encontraba en un 60,11% de eficiencia de funcionamiento en donde se obtuvo resultados poco favorables pues los sistemas de acceso, sistema de videovigilancia, sistema de alarma y sistema contraincendios se encontraban en un estado técnico malo (M) y muy malo (MM) respectivamente. Con todos los antecedentes mencionados se procedió a realizar la repotenciación del mismo, para lo cual se realizó un análisis, selección y diseño de nuevas alternativas de elementos emisores y receptores de señales; los cuales, mediante la intercomunicación entre sí, realizarán las actividades pertinentes. Los resultados obtenidos se los puede evidenciar tanto en el estado físico de cada uno de los elementos o a nivel general, pues éste alcanzó el 98,71% de eficiencia de funcionamiento, así como las ventajas que su uso otorga al modular. Se recomienda que antes de cualquier configuración, reparación o mantenimiento de cada uno de los sistemas se debe tomar en cuenta el manual de funcionamiento y mantenimiento.es_ES
dc.description.abstractIn the modular of the Industrial Maintenance Career there was a home automation system that, due to time and presence of failures in the components, it reached a state of deterioration. Therefore, its use was suspended within the modular, in order to get it back on the road, this system was rehabilitated. Thus, seeking to obtain better benefits in comfort, security, communication, energy savings, etc. As a first step, the level of home automation was evaluated, taking into account the three levels of home automation established by Spanish Home Automation Association. (CEDOM), level 1, level 2, level 3, reflecting as a result a building with no level of home automation. Through the physical analysis of the sensor and controller elements belonging to the system and thanks to the "initial technical state evaluation methodology" it is deduced that the pre-existing home automation system was at 60,11% operating efficiency where results are obtained unfavorable because the access systems, video surveillance system, alarm system and fire-fighting system were in a bad (M) and very bad (MM) technical state, respectively. With all the aforementioned background, the repowering of it was carried out. An analysis, selection and design of new alternatives of signal emitting and receiving elements was carried out, which, through intercommunication with each other, will carry out the pertinent activities. The results obtained can be evidenced both in the physical state of each of the elements or at a general level, since it reached 98,71% of operating efficiency, as well as the advantages that its use gives to the modular system. It is recommended that before any configuration, repair or maintenance of each of the systems, the operation and maintenance manual should be taken into account.es_ES
dc.language.isospaes_ES
dc.publisherEscuela Superior Politécnica de Chimborazoes_ES
dc.relation.ispartofseriesUDCTFM;25T00497-
dc.rightsinfo:eu-repo/semantics/openAccesses_ES
dc.subjectDOMOTIZACIÓNes_ES
dc.subjectSISTEMA DE ACCESOes_ES
dc.subjectSISTEMA DE ALARMAes_ES
dc.subjectSISTEMA DE VIDEOVIGILANCIAes_ES
dc.subjectSISTEMA CONTRAINCEDIOSes_ES
dc.subjectSISTEMA DE ILUMINACIÓNes_ES
dc.titleRepotenciación y puesta en funcionamiento del sistema de control domótico para las instalaciones del edificio de la Carrera de Mantenimiento Industriales_ES
dc.typeinfo:eu-repo/semantics/bachelorThesises_ES
dc.contributor.miembrotribunalMontalvo Jaramillo, Pablo Ernesto-
dc.rights.urihttps://creativecommons.org/licenses/by-nc-sa/3.0/ec/es_ES
Aparece en las colecciones: Ingeniero de Mantenimiento; Ingeniero/a en Mantenimiento Industrial

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
25T00497.pdf3,79 MBAdobe PDFVista previa
Visualizar/Abrir


Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons Creative Commons