Por favor, use este identificador para citar o enlazar este ítem: http://dspace.espoch.edu.ec/handle/123456789/1721
Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.contributor.advisorRomero, Paúl-
dc.contributor.authorUsca Caillagua, Jéssica María-
dc.contributor.authorIglesias Vargas, Bayron Teofilo-
dc.date.accessioned2012-03-13T23:57:50Z-
dc.date.available2012-03-13T23:57:50Z-
dc.date.issued2011-11-
dc.identifier.citationUsca Caillagua, Jéssica María; Iglesias Vargas, Bayron Teofilo. (2011). Diseño de un sistema de monitoreo y adquisición de datos de la Planta de Extracción de Agua Llio mediante una red de microcontroladores que transmite a través de un radioenlace microoonda entre el EP-EMAPAR y Llio. Escuela Superior Politécnica de Chimborazo. Riobamba.es_ES
dc.identifier.urihttp://dspace.espoch.edu.ec/handle/123456789/1721-
dc.descriptionDiseño del sistema de monitoreo y adquisición de datos de la planta de extracción de agua LLIO mediante red de microcontroladores que transmite a través de un radio enlace microonda entre la Empresa Municipal de Agua Potable y Alcantarillado Riobamba y Llio permitirá analizar ldatos obtenidos a través de los sistemas de adquisición. Se utilizó los métodos inductivo, científico y experimental para la investigación y toma de decisiones, el diseño del sistema de monitoreo LLIO COMUNICATION es un documento que facilita la instalación de componentes del sistema ya sean estos la aplicación creada sobre el lenguaje de programación C# de Visual Studio y la base de datos en Sql Server 2000 además adecuar los equipos y complementos de la red externa que permite el monitoreo desde las oficinas ubicadas en el Cantón Riobamba al sistema de extracción de agua ubicada en la parroquia Llio del cantón Guano mediante un radio enlace microondas, la red interna obtiene los datos a través de sistemas microcontrolados específicos para cada tipo de estación. El sistema de pozo utiliza un sensor magnético que permite detectar el nivel del pozo recolector, un sensor final de carrera detecta si existe caudal y un contacto auxiliar del sistema de control de la bomba de extracción para conocer su funcionamiento. En el sistema de tanque de almacenamiento se utiliza un sensor ultrasónico para detectar el nivel de agua almacenada. Estos datos adquiridos son transmitidos mediante los protocolos de comunicación RS - 485 e I²C y para el ingreso de datos en la PC se utiliza comunicación USB. Al realizar el cálculo estadístico aplicando JI Cuadrado el resultado fue 21.17 con 1 grados de libertad tiene una probabilidad inferior a 0.001 y menor que 0.05, cayendo en el nivel de significancia. Por lo tanto, se acepta la hipótesis planteada en esta tesis. Se concluye que el análisis de los datos obtenidos mediante el sistema de monitoreo le permiten a la EP-EMAPAR detectar daños y solucionarlos a tiempo.es_ES
dc.description.abstractThe acquisition systems permit to analyze obtained data. This water extraction plant equipment frequently gets damaged, therefore the Municipality of Riobamba needs to improve the water extraction system for LIio plant from the EP-EMAPAR (Public Company Rio potable water and sanitary sewer Municipal Company) Themain goal is to generate a document that allows EP-EMAPAR the installation and starting of a monitoring system for this extraction plant. The research used inductive, scientific, experimental methods, and taking of decisions. The monitoring systems LLIO coMUNICATTON design is a document that facilitates the installing of the system components. These components are from the created application on programing language Ca from Visual Studio, and data base on SOL Server 2000. Adapting equipment and external network complements permits to monitor from the offices in Riobamba the extraction systems in (Guano Canton) Lio with the use microwave radio links. The intemal network obtains data through specific micro controlled systems for each type of station. The system in the well uses a magnetic sensor to detect the level in the collector. At the end of the run another sensor detects the volume of now and auxiliary contact o the extractor bomb control system to know its functioning The storage tank system uses an ultrasonic sensor to detect the level of stored water. The communication protocol RS 485 e l'C transmits these data, and communication USB (Universal Serial Bus) input data into the PC (Personal Computer) Statistical calculation was made applying Chi-squared distribution, and it showed his result 21.17 with 1 degree of freedom, a probability inforior to 0.001. and less than 0 05 therefore, this is statistically significant and it proves the hypothesis In conclusion, the analysis of monitoring system obtained data permits the EP EMAPAR detect future damages and timing solutions. The system monitoring installation must be done with all described equipment since this research analyzad all decribed equipment an dthey achieved the requirements for this application.es_ES
dc.language.isospaes_ES
dc.publisherEscuela Superior Politécnica de Chimborazoes_ES
dc.relation.ispartofseriesUDCTFIYE;108T0016-
dc.subjectDISEÑO DE SISTEMAS DE MONITOREOes_ES
dc.subjectSISTEMA DE ADQUISICION DE DATOSes_ES
dc.subjectPLANTAS DE EXTRACCION DE AGUAes_ES
dc.subjectREDES DE MICROCONTROLADORESes_ES
dc.subjectDISEÑO DE REDES DE COMUNICACIÓNes_ES
dc.subjectRADIOENLACES MICROONDASes_ES
dc.titleDiseño de un sistema de monitoreo y adquisición de datos de la Planta de Extracción de Agua Llio mediante una red de microcontroladores que transmite a través de un radioenlace microoonda entre el EP-EMAPAR y Llio.es_ES
dc.typebachelorThesises_ES
dc.contributor.miembrotribunalHaro, Daniel-
Aparece en las colecciones: Ingeniero en Electrónica, Control y Redes Industriales; Ingeniero/a en Electrónica y Automatización