Por favor, use este identificador para citar o enlazar este ítem:
http://dspace.espoch.edu.ec/handle/123456789/15056
Registro completo de metadatos
Campo DC | Valor | Lengua/Idioma |
---|---|---|
dc.contributor.advisor | Pachacama Choca, Richard Willians | - |
dc.contributor.author | Meza Vargas, Adrian Nikolay | - |
dc.date.accessioned | 2022-03-10T20:32:21Z | - |
dc.date.available | 2022-03-10T20:32:21Z | - |
dc.date.issued | 2021-09-16 | - |
dc.identifier.citation | Meza Vargas, Adrian Nikolay. (2021). Irradiación de diferentes materiales (agujas, mascarillas y batas) usados en el área de la medicina con la fuente radiactiva de uranio-238 a diferentes dosis para determinar los efectos generados. Escuela Superior Politécnica de Chimborazo. Riobamba. | es_ES |
dc.identifier.uri | http://dspace.espoch.edu.ec/handle/123456789/15056 | - |
dc.description | El presente trabajo de investigación tuvo como objetivo, irradiar materiales usados en el área de la medicina (mascarillas, batas y agujas) con una fuente de Uranio-238, con el fin de observar los respectivos cambios microbiológicos que puedan suceder. Se utilizó la técnica ISO 11137-1, el manual de irradiación de la OEA “Pautas para esterilización por radiación industrial de productos médicos desechables (cobalto-60 irradiación gamma)”, y el software Solid Works para la creación de un diseño experimental que cumpla las necesidades requeridas. Se irradiaron a las muestras en tres fracciones de tiempo (20, 40, 60 minutos), y se verificó el cambio microbiológico que existe mediante un conteo pre y post-microbiológico usando la técnica de siembra en superficie para agujas y contacto en superficie para mascarillas y batas, obteniendo los siguientes resultados: En agujas para los primeros veinte minutos en agujas hubo una reducción de 13.21%, transcurrido los siguientes veinte minutos la reducción fue de 7.41% y finalmente fue de 14.71%. Las batas tuvieron una disminución del 11.43% en los primeros veinte minutos, seguido de una reducción del 80.56% y finalmente transcurrida una hora fue de 79.41%. Las mascarillas en los primeros veinte minutos se redujeron un 2.86%, posteriormente 74.70% para finalmente reducirse en un 92.27% concluyendo que la fuente radiactiva no llegó a una esterilización o disminución de microrganismos a los niveles que permite la ISO, pero se puede demostrar la viabilidad que tiene esta investigación en el campo de la radiación para posteriores trabajos, además se recomienda tener en consideración el aseo del lugar del trabajo para no tener falsas lecturas de microorganismos. | es_ES |
dc.description.abstract | The aim of this research work was to irradiate materials used in the medical field (masks, gowns, and needles) with a source of Uranium-238, to observe the respective microbiological changes that may occur. The ISO 11137-1 technique, the OAS irradiation manual "Guidelines for industrial radiation sterilization of disposable medical devices (cobalt-60 gamma irradiation)", and Solid Works software were used to create an experimental design that meets the required needs. The samples were irradiated in three-time fractions (20, 40, 60 minutes), and the microbiological change was verified by means of a pre- and post-microbiological count using the surface seeding technique for needles and surface contact for masks and gowns, obtaining the following results: In needles for the first twenty minutes there was a reduction of 13.21%, after the next twenty minutes the reduction was 7.41% and finally it was 14.71%. Gowns had a reduction of 11.43% in the first twenty minutes, followed by a reduction of 80.56% and finally after one hour it was 79.41%. The masks were reduced by 2.86% in the first twenty minutes, then by 74.70% and finally by 92.27%, concluding that the radioactive source did not sterilize or reduce microorganisms to the levels permitted by ISO, but the viability of this research in the field of radiation can be demonstrated for subsequent work, and it is also recommended that the cleanliness of the | es_ES |
dc.language.iso | spa | es_ES |
dc.publisher | Escuela Superior Politécnica de Chimborazo | es_ES |
dc.relation.ispartofseries | UDCTFC;86T00153 | - |
dc.rights | info:eu-repo/semantics/openAccess | es_ES |
dc.subject | CIENCIAS EXACTAS Y NATURALES | es_ES |
dc.subject | FÍSICA | es_ES |
dc.subject | IRRADIACIÓN | es_ES |
dc.subject | AGUJA HIPODÉRMICA | es_ES |
dc.subject | BATAS DE LABORATORIO | es_ES |
dc.subject | MASCARILLA QUIRURGICA | es_ES |
dc.subject | DOSIS ABSORBIDA | es_ES |
dc.subject | URANIO-238 | es_ES |
dc.title | Irradiación de diferentes materiales (agujas, mascarillas y batas) usados en el área de la medicina con la fuente radiactiva de uranio-238 a diferentes dosis para determinar los efectos generados | es_ES |
dc.type | info:eu-repo/semantics/bachelorThesis | es_ES |
dc.contributor.miembrotribunal | Cortez Bonilla, Luis Marcelo | - |
dc.rights.uri | https://creativecommons.org/licenses/by-nc-sa/3.0/ec/ | es_ES |