dc.identifier.citation | Diseño y Cálculo de blindajes para zonas de alto riesgo radiológico en Ganán Andino, Mary Elizabeth. (2018). Unidad de Medicina Nuclear del Hospital Teodoro Maldonado Carbo, IESS - Guayaquil. Escuela Superior Politécnica de Chimborazo. Riobamba. | es_ES |
dc.identifier.uri | http://dspace.espoch.edu.ec/handle/123456789/8604 | - |
dc.description | El presente trabajo tiene como objetivo el diseño y cálculo del blindaje para una instalación SPECT-CT en la Unidad de Medicina Nuclear del Hospital Teodoro Maldonado Carbo IESS Guayaquil. Para ello se tuvo en cuenta las consideraciones técnicas de radioprotección aplicadas por Organismos internacionales: National Council on Radiation Protection and Measurements (NCRP) de los Estados Unidos en sus recomendaciones No. 147 y 151, en los reportes The American Association of Physicists in Medicine (AAPM) en su reporte TG-108, el Consejo de Seguridad Nuclear de España (CSN 5.11) y por el Organismo Internacional de Energía Atómica (OIEA SRS-2/1). Para el cálculo de blindaje se utilizó una hoja programada en MATLAB donde se tuvieron en cuenta las restricciones de dosis: personal ocupacionalmente expuesto (100 microsievert/semana) así como el público (20 microsievert/semana). El radiofármaco tomado como referencia fue el Yodo-131. Los resultados obtenidos en la presente investigación fueron el diseñó 30 locales, de ellos 11 necesitaron protección de blindaje. Se concluye que los espesores de la barrera de protección en plomo y concreto de los 11 locales que necesitan protección fueron: para concreto de 25 a 65cm y para plomo de 4 a 10mm. Se recomienda realizar nuevos cálculos de blindaje en las barreras de protección si se varía el diseño original propuesto e implementar un programa de Protección Radiológica con el fin de comprobar el cumplimiento de los límite de dosis establecidos por la Autoridad Reguladora. | es_ES |
dc.description.abstract | The objective of this work is the design and calculation of shielding for a SPECT-CT installation in the Nuclear Medicine Unit of the Teodoro Maldonado Carbo IESS-Guayaquil. To this end, the radioprotection technical considerations applied by international organizations were taken in to account: the National Council on Radiation Protection and Measurements (NCRP) of the United in its recommendations N0. 147 and 151, in the reports The American Association of Physicians in Medicine (AAPM) in its report TG-108, the Nuclear Safety Council of Spain (CSN 5.11) and the International Atomic Energy Agency (IAEA SRS-2/1). For the calculation of shielding, a sheet programmed in MATLAB was used, taking in to account dose restrictions: occupationally exposed personnel (100 microsievert/sem) as well as the public (20 microsievert/sem). The radiopharmaceutical taken as reference was Iodine-131. The results obtained in the present investigation were the design of 30 locations, of which 11 needed shielding protection. It is concluded that the thickness of the protection barrier in lead and concrete of the 11 premises that need protection were: for concrete form 25 to 65cm and for lead from 4 to 10mm, It is recommended to carry out new shielding calculations in the protection barriers if the proposed original design is varied and Radiological Protection program is implemented in order to verify compliance with the dose limits established by the Regulatory Authority. | es_ES |
dc.language.iso | spa | es_ES |
dc.publisher | Escuela Superior Politécnica de Chimborazo | es_ES |
dc.relation.ispartofseries | UDCTFC;86T00063 | - |
dc.subject | BIOFÍSICA | es_ES |
dc.subject | MEDICINA NUCLEAR | es_ES |
dc.subject | RADIOPROTECCIÓN | es_ES |
dc.subject | CÁLCULO DE BLINDAJE | es_ES |
dc.subject | RADIOFÁRMACO | es_ES |
dc.title | Diseño y Cálculo de blindajes para zonas de alto riesgo radiológico en la Unidad de Medicina Nuclear del Hospital Teodoro Maldonado Carbo, IESS - Guayaquil. | es_ES |
dc.type | bachelorThesis | es_ES |
dc.contributor.miembrotribunal | González López, Nadia | - |