Por favor, use este identificador para citar o enlazar este ítem:
http://dspace.espoch.edu.ec/handle/123456789/8367
Registro completo de metadatos
Campo DC | Valor | Lengua/Idioma |
---|---|---|
dc.contributor.advisor | Yanchapanta Bastidas, Vilma Nohemí | - |
dc.contributor.author | Allauca Ortega, Erika Andrea | - |
dc.date.accessioned | 2018-06-19T13:29:49Z | - |
dc.date.available | 2018-06-19T13:29:49Z | - |
dc.date.issued | 2018-03 | - |
dc.identifier.citation | Allauca Ortega, Erika Andrea. (2018). Determinación de la dosis absorbida acumulada en pacientes con cáncer diferenciado de tiroides que reciben Yodo 131 en el Área de Medicina Nuclear del Hospital de Especialidades “Teodoro Maldonado Carbo” IESS – Guayaquil. Escuela Superior Politécnica de Chimborazo. Riobamba. | es_ES |
dc.identifier.uri | http://dspace.espoch.edu.ec/handle/123456789/8367 | - |
dc.description | El objetivo del trabajo fue determinar la dosis absorbida acumulada en sangre a los pacientes con Cáncer Diferenciado de Tiroides (CDT) que requieren Yodo 131 (131I) como modalidadterapéutica, en el Hospital de Especialidades “Teodoro Maldonado Carbo” (HTMC) IEES –Guayaquil septiembre - marzo 2018. Para ello se diseñó un software de aplicación dosimétrico utilizando el formalismo Medical Internal Radiation Dose (MIRD), calculando la dosis absorbida acumulada en sangre por unidad de actividad trazadora y la máxima actividad permisible de 131I que requiere un paciente que padece esta patología. Los resultados obtenidos de la dosimetría preterapéutica en sangre por el software de aplicación dosimétrico fueron de 0.2307 ± 0.004 [Gy GBq⁄ ], valor que se encuentra dentro del límite máximo de dosis permisible para médula ósea y la actividad única calculada para suministrar al paciente fue de 234.1873 ± 0.004 [mCi], valor máximo permisible para este tipo de tratamiento. Este trabajo constituye una herramientacomputacional eficaz para el desarrollo de este tipo de cálculo en pacientes CDT en diferentes instalaciones hospitalarias. | es_ES |
dc.description.abstract | The aim of the study was to determine the cumulative absorbed dose in blood to the patients with Differentiated Thyroid Cancer (DTC) requiring Iodine 131 (131I) as a therapeutic modality, in the Hospital of Specialties "Teodoro Maldonado Carbo "(HTMC) IESS - Guayaquil September - March 2018. To do this, a dosimeter application software was designed using the Medical Internal Radiation Dose (MIRD) formalism, calculating the accumulated absorbed dose in blood per unit of tracer activity and the maximum permissible activity of 131I required by a patient suffering from this pathology. The results obtained from the pre-therapeutic dosimetry in blood by the dosimeter application software were 0.2307 ± 0.004 [Gy GBq⁄ ], a value that is within the maximum permissible dose limit for bone marrow and the single activity calculated for the patient was given 234.1873 ± 0.004 [mCi], the maximum permissible value for this type of treatment. This work constitutes an effective computational tool for the development of this type of calculation in CDT patients in different hospital facilities | es_ES |
dc.language.iso | spa | es_ES |
dc.publisher | Escuela Superior Politécnica de Chimborazo | es_ES |
dc.relation.ispartofseries | UDCTFC;86T00058 | - |
dc.subject | BIOFÍSICA | es_ES |
dc.subject | MEDICINA NUCLEAR | es_ES |
dc.subject | DOSIS EN SANGRE | es_ES |
dc.subject | CÁNCER DE TIROIDES DIFERENCIADO (CDT) | es_ES |
dc.subject | YODO 131 (131 I) | es_ES |
dc.subject | RETENCIÓN EN CUERPO ENTERO | es_ES |
dc.subject | CONCENTRACIÓN DE ACTIVIDAD EN SANGRE | es_ES |
dc.title | Determinación de la dosis absorbida acumulada en pacientes con cáncer diferenciado de tiroides que reciben Yodo 131 en el Área de Medicina Nuclear del Hospital de Especialidades “Teodoro Maldonado Carbo” IESS – Guayaquil. | es_ES |
dc.type | bachelorThesis | es_ES |
dc.contributor.miembrotribunal | González López, Nadia | - |
Aparece en las colecciones: | Biofísica |
Ficheros en este ítem:
Fichero | Descripción | Tamaño | Formato | |
---|---|---|---|---|
86T00058.pdf | 2,1 MB | Adobe PDF | Visualizar/Abrir |
Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.