dc.identifier.citationSaqui Moyolema, Claudio Fernando. (2016). Análisis de fallos y evaluación energética de anomalías en conductores eléctricos de potencia mediante termografía. Escuela Superior Politécnica de Chimborazo. Riobamba.es_ES
dc.identifier.urihttp://dspace.espoch.edu.ec/handle/123456789/8037-
dc.descriptionLa investigación realizada tiene como objetivos: detectar la falla por sobrecalentamiento, realizar el estudio y análisis del comportamiento de los calibres de los conductores eléctricos de potencia mediante el uso de la técnica de termografía. El medio para conseguir esta anomalía es mediante una motobomba eléctrica con capacidad de 2HP, el cálculo de calibre de conductor adecuado es número 14, en el estudio se pretende realizar un subdimensionamiento del calibre hasta llegar a un numero 24, el proceso de análisis de la falla se lo realiza mediante el AMEF (Análisis de Modo y Efecto de Fallo); y se determinan diferentes variables y posibles modos de fallos, también la detección de anomalías mediante termografía que es una técnica del mantenimiento preventivo. Se realizan las pruebas respectivas en el módulo para la detección de fallas en conductores eléctricos presente en el laboratorio de Mantenimiento Preventivo se obtienen datos confiables, además se recure a un equipo de medida que analiza la calidad energética, de esta manera se observa el comportamiento de la caída de voltaje y la potencia en su calibre al momento de subdimensionarlos. Se realiza un modelo comparativo mediante gráficos considerando la pérdida de potencia en el conductor en relación al calentamiento del mismo, de esta manera se detectan pérdidas del coste energético que no se aprovecha en el consumidor. Este trabajo tiene como fin demostrar que realmente existe pérdida de energía en forma de calor en los conductores eléctricos, pese a que el conductor esté con el calibre adecuado.es_ES
dc.description.abstractThe research carried out has the following objectives: to detect the failure due to overheating, to carry out he study and analysis of the behavior of the gauges of electrical power conductors by the use of thermography technique. The means to achieve this anomaly is by means of an electric motor pump with capacity of 2 HP, the calculation of suitable conductor gauge is number 14, in the study it is tried to carry out a dimensioning of the gauge until reaching a number 24, in the process of analysis of the failure is done by means of the AMEF (Analysis of Mode and effect of Failure); And different variables and possible failure modes are determined, as well as the detection of anomalies by means of thermography, which is a preventive maintenance technique. The respective test are performed in the module for the detection of faults in electric conductors present in the Laboratory of Preventive Maintenance are obtained reliable data also recure to a measuring equipment that analyzes the energy quality in this way is observed the behavior of the fall voltage and power in their gauge at the time of undersizing. A comparative model is made by graphs considering the loss of power in the conductor in relation to the heating of the same, in this way are detected losses of the energetic cost that does not take advantage of the consumer. This work has the purpose of demonstrating that there is a loss of energy in the form of heat in the electric conductors, despite the fact that the conductors is with the right gauge.es_ES
dc.language.isospaes_ES
dc.publisherEscuela Superior Politécnica de Chimborazoes_ES
dc.relation.ispartofseriesUDFM;25T00315-
dc.subjectTERMOGRAFÍAes_ES
dc.subjectMODOS DE FALLOSes_ES
dc.subjectMANTENIMIENTO PREVENTIVOes_ES
dc.subjectEQUIPOS Y HERRAMIENTASes_ES
dc.subjectCONDUCTORES ELÉCTRICOSes_ES
dc.subjectCALIDAD ENERGÉTICAes_ES
dc.subjectINSTRUMENTACIÓN DE LABORATORIOes_ES
dc.subjectANÁLIS DE MODO Y EFECTO DE FALLOes_ES
dc.titleAnálisis de fallos y evaluación energética de anomalías en conductores eléctricos de potencia mediante termografía.es_ES
dc.typebachelorThesises_ES
dc.contributor.miembrotribunalHernández Dávila, Eduardo Segundo-
Aparece en las colecciones: Ingeniero de Mantenimiento; Ingeniero/a en Mantenimiento Industrial

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
25T00315.pdf1,91 MBAdobe PDFVista previa
Visualizar/Abrir


Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.