dc.identifier.citation | Villacrés Rodríguez, Mario Germán. (2017). Diseño e instalación de un sistema de control, supervisión y monitoreo para la compuerta de restitución tipo vagón de la Central Hidroeléctrica San Francisco mediante el uso de un PLC de una interfaz humano – máquina. Escuela Superior Politécnica de Chimborazo. Riobamba. | es_ES |
dc.identifier.uri | http://dspace.espoch.edu.ec/handle/123456789/6878 | - |
dc.description | Se desarrolló un sistema de control, supervisión y monitoreo para la compuerta de restitución tipo vagón de la Central Hidroeléctrica San Francisco mediante el uso de un Controlador Lógico Programable (PLC) y una Interfaz Humano – Máquina (HMI) que permite la salida de agua turbinada de las dos unidades de generación y a su vez evita el ingreso de agua desde el río Pastaza cuando la central se encuentra fuera de servicio. La compuerta de restitución posee un tablero de control automático que permitió operar la compuerta en mando manual para su apertura, cierre normal y cierre de emergencia. Este tablero realizó el control mediante un PLC marca SIEMENS modelo S7-1200 CPU 1212C DC/DC/RLY y un HMI marca SIEMENS modelo KTP-900 los cuales se comunican mediante protocolo ETHERNET. Con el fin de mejorar el sistema de control se realizó los diagramas de instrumentación de procesos (P&ID), se modificó planos eléctricos y electrónicos, se instaló nuevos dispositivos e interfaces de acuerdo a los requerimientos que la empresa deseó. Se realizó las pruebas en cada etapa de la carrera de la compuerta en el nuevo sistema de control a través del software simulador de SIEMENS en el tablero de pruebas para su posterior implementación en el túnel de restitución comprobando así los datos técnicos entregados por la constructora del proyecto con los obtenidos en el proyecto mediante su monitoreo y supervisión en el HMI. Se concluyó que el nuevo sistema de control para la compuerta de restitución garantiza un aumento en su confiabilidad y la reducción del número de fallas. Se recomienda realizar mantenimientos más rutinarios en el sistema de control de la compuerta de restitución para evaluar el funcionamiento correcto de los dispositivos eléctricos, sensores y actuadores que lo conforman. | es_ES |
dc.description.abstract | A control, supervision and monitoring system was developed for the fixed wheel floodgate at the San Francisco Hydroelectric Power Station, through the use of a Programmable Logic Controller (PLC) and a Human Machine Interface (HMI) that allows the outflow of turbine water from the two generation units and in turn prevents the entry of water from the Pastaza river when the plant is out of service. The floodgate has an automatic control panel that allows for the manual operation of the gate for opening, normal closure and emergency closure. This panel is controlled via a SIEMENS PLC, model S7-1200, CPU 1212C DC/DC/RLY and a SIEMENS HMI, model KTP-900, which communicate via ETHERNET protocol. In order to improve the control system, piping and instrumentation (P&ID) diagrams were drawn up, the electrical and electronic plans were modified, and new devices and interfaces were installed according to the company’s requirements. Tests were carried out at each of the gate’s stages in the new control system via the SIEMENS software simulator in the testing panel for its later implementation in the tunnel, thus verifying the technical data delivered with the project construction with those obtained in the project through HMI monitoring and supervision. As a result it was concluded that the new control system for the floodgate guarantees an increase in reliability and a reduction in the number of failures. More regular routine maintenance is recommended for the floodgate control system in order to monitor the correct operation of the electrical devices, sensors and actuators that make it up the system. | es_ES |
dc.language.iso | spa | es_ES |
dc.publisher | Escuela Superior Politécnica de Chimborazo | es_ES |
dc.relation.ispartofseries | UDCTFIYE;108T0197 | - |
dc.subject | TECNOLOGÍA Y CIENCIAS DE LA INGENIERÍA | es_ES |
dc.subject | CONTROL AUTOMÁTICO | es_ES |
dc.subject | AUTOMATIZACIÓN DE PROCESOS INDUSTRIALES | es_ES |
dc.subject | COMPUERTAS HIDRÁULICAS | es_ES |
dc.subject | INSTRUMENTACIÓN DE PROCESOS INDUSTRIALES | es_ES |
dc.subject | PROCESAMIENTO DE DATOS | es_ES |
dc.title | Diseño e instalación de un sistema de control, supervisión y monitoreo para la compuerta de restitución tipo vagón de la Central Hidroeléctrica San Francisco mediante el uso de un PLC de una interfaz humano – máquina. | es_ES |
dc.type | bachelorThesis | es_ES |
dc.contributor.miembrotribunal | Viteri, Marco | - |
Aparece en las colecciones: | Ingeniero en Electrónica, Control y Redes Industriales; Ingeniero/a en Electrónica y Automatización |
Ficheros en este ítem:
Fichero | Descripción | Tamaño | Formato | |
---|---|---|---|---|
108T0197.pdf | 6,26 MB | Adobe PDF | Visualizar/Abrir |
Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.