Por favor, use este identificador para citar o enlazar este ítem: http://dspace.espoch.edu.ec/handle/123456789/6484
Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.contributor.advisorBrito, Hanníbal-
dc.contributor.authorHaro Velastegui, Carla Viviana-
dc.date.accessioned2017-05-23T13:57:02Z-
dc.date.available2017-05-23T13:57:02Z-
dc.date.issued2016-06-
dc.identifier.citationHaro Velastegui, Carla Viviana. (2016). Optimización del sistema de tratamiento de aguas residuales de porcelanato Ecuacerámica – Riobamba. Escuela Superior Politécnica de Chimborazo. Riobamba.es_ES
dc.identifier.urihttp://dspace.espoch.edu.ec/handle/123456789/6484-
dc.descriptionEl objetivo del estudio técnico fue optimizar el sistema de tratamiento de aguas residuales de la planta de porcelanato Ecuacerámica – Riobamba, con la finalidad de proporcionar agua de óptima calidad en el sistema de tratamiento actual. A través de análisis físico - químico en muestras de agua cruda y tratada se identificó los parámetros irregulares referentes al Acuerdo Ministerial 097-A Anexo 1 del Libro VI del TULSMA, Tabla 8. Límites de Descarga al Sistema de Alcantarillado Público, se procedió a la determinación del caudal empleando el método del flotador, determinación del diámetro del material particulado presente en el agua y la velocidad de sedimentación empleando técnicas de secado, tamizado y sedimentación; pruebas de jarras para determinar la dosificación adecuada de químico coagulante y químico floculante. La caracterización del agua cruda reflejó que existen problemas en pH, sólidos suspendidos, sólidos totales debido al diámetro de material particulado presente que varía en 8,5x10 -4 m – 3,8x10 -5 m y una velocidad de sedimentación de 2,81x10 xiii -2 m/s – 2,00x10 -4 m/s. Para dar cumplimiento a los parámetros fue necesaria la dosificación de PAC-100 al 5% (p/v) 306L/h y Poly-A al 3% (p/v) 153L/h, readecuación de tanques de dosificación por gravedad y accesorios, implementación de una malla de acero inoxidable en el canal de recolección. Con la implementación de la optimización al sistema actual se obtuvo porcentajes de remoción de 5,94% pH, 99,85% sólidos suspendidos, 84,66% sólidos totales y 99,74% turbiedad; valores que cumplen con los límites establecidos, aumentando el rendimiento operacional y mejorando la calidad del agua para el proceso de rectificación. Se recomienda verificar que el rango de pH del agua cruda se encuentre en los límites de 6 a 9.es_ES
dc.description.abstractThe purpose of the technical study was the optimization of the sewage treatment system of Ecuacerámica porcelain plant in order to provide high-quality water for the current treatment system. Through the physical-chemical analysis carried out in polluted and treated water samples, it was possible to identify the irregular parameters according to 097-A Ministry agreement annex 1, book VI, chart 8 of TULSMA regarding to the discharge limits into the public sewage system, it was necessary to determine the water flow by using the floating method as well as the material diameter determination, water particles and sedimentation speed by using drying techniques, filtering and sedimentation; jar tests to determine the appropriate dosage of coagulant and flocculent chemical. The polluted water characterization reflected existing problems related to: pH, suspended solids, and total solids, this due to the sand material diameter which varies between 8,5x10 -4 m - 3,8x10 xiv -5 m at a sedimentation speed of 2,81x10 -2 m/s-2,00x10 -4 m/s. In order to accomplish the parameters it was necessary to use the PAC100dosage at 5% (p/v) 306 L/h and Poly –A at 3% (p/v) 153L/h for the gravity dosage tanks readjustment as well as their accessories, implementation of an iron mesh in the collecting channel. With the implementation of the current system optimization it was possible to obtain removal percentages of 5,94% pH, 99,85%suspended solids, 84,66%total solids, and 99,74% turbidity; these values reach the established limits increasing the operational performance and improving the water quality for the modification process. It is recommended to verify the polluted water pH average under the 6 to 9 limits.es_ES
dc.language.isospaes_ES
dc.publisherEscuela Superior Politécnica de Chimborazoes_ES
dc.relation.ispartofseriesUDCTFC;96T00355-
dc.subjectSISTEMA DE TRATAMIENTO DE AGUAS RESIDUALESes_ES
dc.subjectOPTIMIZACIÓN DEL PROCESOes_ES
dc.subjectPROCESO DE RECTIFICACIÓNes_ES
dc.subjectCARACTERIZACIÓN DEL AGUAes_ES
dc.subjectANÁLISIS FÍSICOes_ES
dc.subjectANÁLISIS QUÍMICOes_ES
dc.subjectINGENIERÍA Y TECNOLOGÍA QUÍMICAes_ES
dc.titleOptimización del sistema de tratamiento de aguas residuales de porcelanato Ecuacerámica – Riobamba.es_ES
dc.typebachelorThesises_ES
dc.contributor.miembrotribunalUsiña, José-
Aparece en las colecciones: Ingeniero/a Químico/a

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
96T00355.pdf1,84 MBAdobe PDFVista previa
Visualizar/Abrir


Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.