Por favor, use este identificador para citar o enlazar este ítem: http://dspace.espoch.edu.ec/handle/123456789/6469
Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.contributor.advisorAndrade, Mónica-
dc.contributor.authorFreire Chafla, Cristian Marcelo-
dc.date.accessioned2017-05-22T14:27:59Z-
dc.date.available2017-05-22T14:27:59Z-
dc.date.issued2016-05-
dc.identifier.citationFreire Chafla, Cristian Marcelo. (2016). Optimización del proceso de potabilización de agua en la planta de tratamiento Colonso: Tena. Escuela Superior Politécnica de Chimborazo. Riobamba.es_ES
dc.identifier.urihttp://dspace.espoch.edu.ec/handle/123456789/6469-
dc.descriptionSe optimizó el proceso de potabilización de agua en la Planta de Tratamiento Coloso-Tena, con el objetivo de obtener agua de calidad para el consumo humano y reducir los costos de operación, motivo por el que se realizaron análisis de laboratorio para determinar las características físicas, químicas y microbiológicas, para esto se muestreo en diferentes punto: agua de vertiente, cruda y potable en condiciones críticas de la zona donde se identificó los parámetros en épocas invernales: color, turbiedad, alcalinidad, fosfatos, nitritos y hierro que se encontraban fuera de norma INEN 1108: 2006, los parámetros antes mencionados fueron sometidos a pruebas se tratabilidad con el método de Test de jarra y el uso de Sulfato de aluminio, y cal. Mediante los resultados obtenidos en las pruebas de caracterización se determinó los porcentaje de remoción para los siguientes parámetros: turbiedad 97,75%, color 98,46%, nitritos 75,61%, hierro 68,18%.son datos que reflejan la mejoría en la calidad de agua con la nueva dosificación del Alum. La validación del tratamiento propuesto para la optimización de la Planta de Tratamiento de agua potable Colonso se realizó con la caracterización final. Al definir de forma técnica los valores y los costos a nivel comercial, se determinó que el gasto por el consumo de sulfato de aluminio es menor a la del tratamiento actual, siendo este $ 354,59 por día en épocas de lluvia específicamente. El estudio de optimización debe implementarse en la Planta de Tratamiento de agua potable Colonso, con una cantidad de Sulfato de Aluminio de 466,56Kg/día y 233,28Kg/día de cal concentraciones determinadas en el estudio realizado.es_ES
dc.description.abstractIt was optimized the process water treatment plant Colonso: Tena, with the object of obtain quality water for human consumption and reduce the operating costs, for that reason they were conducted laboratory tests to determine the physical, chemical and microbiological characteristics, for this was sampled in different points: water shed, raw and drinking in critical conditions of the area where the parameters were identified in the winter times: color, turbidity, alkalinity, phosphates, nitrites and iron they were outside the norm INEN 1108:2006, The parameters before mentioned were tested with treatability with the Pitcher Test method and using aluminum sulphate and lime. By the results of characterization tests removal percentages for the following parameters it was determined: 97.75% Color, Turbidity 98.46%, 75.61% iron nitrites 68.18% are data reflecting the improvement in water quality with the new dosage Alum. The validation of Colonso drinking water treatment proposed in order to optimization of the plant water treatment Colonso was performed with the final characterization. When defining technical form values and costs at the commercial level, it was determined that the expense for the consumption of aluminum sulfate is less than the current treatment, I feel this $ 354.59 per day in the rainy season specifically. The optimization study should be implemented in the plant Drinking water treatment Colonso, with an amount of aluminum sulfate 466,56Kg / day and 233,28Kg / day lime certain concentrations in the study conducted.es_ES
dc.language.isospaes_ES
dc.publisherEscuela Superior Politécnica de Chimborazoes_ES
dc.relation.ispartofseriesUDCTFC;96T00346-
dc.subjectPROCESO DE POTABILIZACIÓNes_ES
dc.subjectCALIDAD DEL AGUAes_ES
dc.subjectNORMA INEN 1108: 2006es_ES
dc.subjectCOLONSO (PARROQUIA)es_ES
dc.subjectTENA (CANTÓN)es_ES
dc.subjectINGENIERÍA Y TECNOLOGÍA QUÍMICAes_ES
dc.titleOptimización del proceso de potabilización de agua en la planta de tratamiento Colonso: Tena.es_ES
dc.typebachelorThesises_ES
dc.contributor.miembrotribunalChuiza, Marco-
Aparece en las colecciones: Ingeniero/a Químico/a

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
96T00346.PDF4,14 MBAdobe PDFVista previa
Visualizar/Abrir


Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.