dc.contributor.advisor | Hernández Dávila, Eduardo Segundo | - |
dc.contributor.author | Haro Capelo, Johana Nataly | - |
dc.date.accessioned | 2017-02-01T17:12:08Z | - |
dc.date.available | 2017-02-01T17:12:08Z | - |
dc.date.issued | 2016-11-29 | - |
dc.identifier.citation | Haro Capelo, Johana Nataly. (2016). Implementación de un plan de mantenimiento para los laboratorios de las áreas eléctricas y del laboratorio de mantenimiento predictivo de la Facultad de Mecánica mediante el software SisMAC. Escuela Superior Politécnica de Chimborazo. Riobamba. | es_ES |
dc.identifier.uri | http://dspace.espoch.edu.ec/handle/123456789/5901 | - |
dc.description | La implementación de un plan de Mantenimiento de los Laboratorios en las Áreas Eléctricas y del Laboratorio de Mantenimiento Predictivo de la Facultad de Mecánica mediante el software SisMAC, es una guía para la ejecución de tareas de mantenimiento a los equipos de los laboratorios y talleres anteriormente mencionados a través de la metodología del RCM, además se cargó los datos al Software SisMAC, este ayudará a automatizar, controlar y monitorear los procesos de mantenimiento. Inicialmente se realizó el análisis del plan de mantenimiento existente, posterior al análisis del mismo se determina que es un plan de mantenimiento demasiado general y no otorga una información adecuada, es necesario mejorar dicho plan de mantenimiento en base al estado actual y contexto operacional, a continuación se realizó el levantamiento de información técnica de los diferentes equipos, para luego proceder a realizar las fichas técnicas de los mismos, se implementó la codificación de cada equipo según la estructura del software SisMAC, posteriormente se determinó el estado actual de los equipos mediante la aplicación técnicas predictivas (Termografía y Vibraciones), estas ayudaron a corroborar resultados, seguidamente se realizó el análisis de los modos y efecto de falla (AMEF), determinando así las tareas de mantenimiento que necesita cada laboratorio, finalmente se cargaron los datos al software SisMAC para así aumentar la Gestión de Mantenimiento acorde a las necesidades de la Facultad, además se efectuó un check list para todos los laboratorios. Estas actividades se deben de realizar antes y después de la operación de cada equipo. Con este trabajo de titulación se cargaron las tareas del plan de mantenimiento al software SisMAC siendo este el primer paso para la Gestión del Mantenimiento en la Facultad de Mecánica. | es_ES |
dc.description.abstract | The implementation of a Maintenance Plan of laboratories in Electric Areas and the Predictive Maintenance of the Laboratory in Mechanics Faculty thorough SisMAC software, is a guide for the execution of maintenance tasks to the equipment of laboratories and workshops previously mentioned through RCM Methodology, in addition the data was uploaded to the SisMAC software, this will help to automate, control and monitor the maintenance processes. Initially, the analysis of the existing maintenance plan was carried out. After the analysis of the maintenance plan, it was determined that it is a maintenance plan that is too general and does not provide adequate information. It is necessary to improve the maintenance plan based on the current state and operational context. The technical information of the different teams was taken up, then the technical date were implemented, the coding of each equipment was implemented according to the structure of SisMAC Software, and the current state of the equipment was them then determined using the Application of predictive techniques (Thermography and Vibrations), these helped to corroborate results, followed by the analysis of fault-effect modes (AMEF), thus determining the maintenance tasks required by each laboratory, finally loading the data to the SisMAC Software in order to increase the maintenance management according to the Faculty’s needs, also a check list was made for all the laboratories. These activities must be done before and after the operation of each equipment. With this graduating work, the task of the maintenance plan were uploaded to the SisMAC Software being this the first step for the Maintenance Management in the Mechanics Faculty. | es_ES |
dc.language.iso | spa | es_ES |
dc.publisher | Escuela Superior Politécnica de Chimborazo | es_ES |
dc.relation.ispartofseries | UDFM;25T00281 | - |
dc.subject | SISTEMA DE MANTENIMIENTO ASISTIDO POR COMPUTADOR (SISMAC) | es_ES |
dc.subject | MANTENIMIENTO CENTRADO EN LA CONFIABILIDAD (RCM) | es_ES |
dc.subject | PLAN DE MANTENIMIENTO | es_ES |
dc.subject | CONTEXTO OPERACIONAL | es_ES |
dc.subject | ANÁLISIS DE MODO Y EFECTO DE FALLA (AMEF) | es_ES |
dc.subject | GESTIÓN DE MANTENIMIENTO | es_ES |
dc.subject | TECNOLOGÍA ENERGÉTICA | es_ES |
dc.title | Implementación de un plan de mantenimiento para los laboratorios de las áreas eléctricas y del laboratorio de mantenimiento predictivo de la Facultad de Mecánica mediante el software SisMAC. | es_ES |
dc.type | bachelorThesis | es_ES |
dc.contributor.miembrotribunal | Chávez, Verónica | - |
Aparece en las colecciones: | Ingeniero de Mantenimiento; Ingeniero/a en Mantenimiento Industrial |
Ficheros en este ítem:
Fichero | Descripción | Tamaño | Formato | |
---|---|---|---|---|
25T00281.pdf | 3,02 MB | Adobe PDF | Visualizar/Abrir |
Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.