Por favor, use este identificador para citar o enlazar este ítem: http://dspace.espoch.edu.ec/handle/123456789/4941
Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.contributor.advisorMoreno, Franklin.-
dc.contributor.authorChamorro Enríquez, Gabriela Lizeth-
dc.contributor.authorCamacho Gaibor, Fabián Mauricio-
dc.date.accessioned2016-06-16T17:40:10Z-
dc.date.available2016-06-16T17:40:10Z-
dc.date.issued2015-09-24-
dc.identifier.citationChamorro Enríquez, Gabriela Lizeth, y Camacho Gaibor, Fabián Mauricio, (2015). Estudio y Construcción de un Sistema Ventilatorio Pulmonar Controlado. Escuela Superior Politécnica de Chimborazo. Riobamba.es_ES
dc.identifier.urihttp://dspace.espoch.edu.ec/handle/123456789/4941-
dc.descriptionLa necesidad de implementar un equipo médico como el ventilador pulmonar controlado en la empresa Fagove, de bajo precio que cumpla con los requerimientos de equipos existentes en el mercado, se planteó diseñar y construir un sistema ventilatorio pulmonar controlado mediante los métodos investigativo y científico llegando hacer una comparación entre los diferentes sistemas implementados para realizar una selección de los componentes más idóneos para su construcción. Este prototipo se desarrolló mediante una pantalla táctil de 7 pulgadas, una placa de desarrollo arduino, sensores de presión, electroválvulas, válvulas reguladoras, válvulas de sobre presión y una fuente regulada. La combinación de todos los elementos obtuvo como resultado el monitoreo de los parámetros a controlar mediante sensores y activando actuadores según sea necesario, cumpliendo los ciclos de exhalación e inhalación, este procedimiento se realiza con la alimentación de oxígeno y aire, para el control de flujo fue necesario utilizar electroválvulas proporcionales que se manejan mediante la interfaz. Con la realización de la investigación se logró la construcción del equipo ventilatorio con resultados favorables con la determinación de un porcentaje menor al 7% en la sensibilidad de los sensores, verificando lo planteado al principio y con gran porcentaje listo para trabajar en el campo de aplicación así como plasmando con pruebas de calibración necesarias para su uso. En conclusión se determinó que en el país se puede desarrollar equipos con características similares a los existentes reduciendo costos de producción. Se recomienda hacer un mantenimiento periódico del equipo.es_ES
dc.description.abstractIt was necessary to design and build a controlled-pulmonary ventilator system in Fagove Enterprise, whose price is cheap and meet the requirements of the existing equipment in the market that is why this system was designed and built by research and scientific methods comparing the different existing systems to select the best components. This prototype was developed by tactile screen of 7 inches, an Arduino development plate, pressure sensors, electro valves, regulator valves, pressure valves and regulated source. By combining all these elements, monitoring of the parameters to be controlled by sensors was gotten as a result, activating actuators if necessary in order to fulfill the exhalation and inhalation cycles. This precedure is carried out with oxigen and air. Proportional electro valves were used to control the flow managed by means of interface. By this investigation, ventilator equipment was built with good results, wich mean 7% less in sensibility of the sensors achieving the objective of this paper in order to apply tests of calibration necessary for the use. It is concluded that in this country, equipment with similar characteristics to the current ones can be developed reducing production costs. Therefore, it is recommended to give maintenance of the equipment regularly.es_ES
dc.language.isospaes_ES
dc.publisherEscuela Superior Politécnica de Chimborazoes_ES
dc.relation.ispartofseriesUDCTFIYE;108T0131-
dc.subjectVENTILADOR PULMONARes_ES
dc.subjectELECTROVALVULASes_ES
dc.subjectHARDWARE [ARDUINO]es_ES
dc.subjectSENSORESes_ES
dc.subjectEQUIPO MÉDICOes_ES
dc.subjectPANTALLA TÁCTILes_ES
dc.subjectCONTROL DE FLUJOes_ES
dc.titleEstudio y Construcción de un Sistema Ventilatorio Pulmonar Controlado.es_ES
dc.typebachelorThesises_ES
dc.contributor.miembrotribunalCasignia, Byron.-
Aparece en las colecciones: Ingeniero en Electrónica, Control y Redes Industriales; Ingeniero/a en Electrónica y Automatización

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
108T0131.docx3,6 MBMicrosoft Word XMLVisualizar/Abrir


Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.