Por favor, use este identificador para citar o enlazar este ítem: http://dspace.espoch.edu.ec/handle/123456789/4872
Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.contributor.advisorRivera, María Fernanda-
dc.contributor.authorBarrera Jinez, Carlos Fernando-
dc.date.accessioned2016-06-08T15:17:27Z-
dc.date.available2016-06-08T15:17:27Z-
dc.date.issued2015-12-
dc.identifier.citationBarrera Jinez, Carlos Fernando. (2015). Rediseño de la planta de tratamiento de aguas residuales de la lavanderia “Procesos Textiles Llerena” del Cantón Pelileo, año 2015. Escuela Superior Politécnica de Chimborazo. Riobamba..es_ES
dc.identifier.urihttp://dspace.espoch.edu.ec/handle/123456789/4872-
dc.descriptionSe rediseñó la planta de tratamiento de aguas residuales procedentes de la lavandería Procesos Textiles Llerena ubicada en el cantón Pelileo, provincia de Tungurahua, tomando como base la caracterización del agua residual, mediante método analítico. Se inició por el reconocimiento de cada uno de los procesos que se desarrollan en la lavandería, los cuales comprenden lavado y tinturado de prendas jeans, para luego realizar análisis de las aguas residuales. Para recolectar los datos se utilizó muestreo sistemático, partiendo del diseño con el cual cuenta actualmente las instalaciones de la lavandería y finalmente se describió cada etapa del tratamiento. Al caracterizar el agua residual proveniente de las etapas de Lavandería Procesos Textiles Llerena, se obtuvo como resultado: 780 mg/L de Demanda Química de Oxígeno, 507 mg/L de Demanda Bioquímica de Oxígeno, 447 mg/L sulfatos, sobre los que se trabajó con el fin de disminuir la contaminación, porque no cumplen con los límites de descarga establecidos en el Texto Unificado de Legislación Ambiental. A partir de los análisis se determinó que las operaciones requeridas para el rediseño de la planta de tratamiento de aguas residuales deben incluir: rejillas, tanque desarenador, aireador de bandejas, y tratamiento con ozono; que aseguren que el efluente cumpla con los parámetros de acuerdo a los límites permisibles de la norma vigente del TULSMA Libro VI tabla 9. Se recomienda al jefe de operación y seguridad de la empresa se comprometan acciones hacia el cumplimiento del plan de manejo ambiental con el que cuenta la empresa.es_ES
dc.description.abstractThe treatment plant waste water from the laundry “Procesos Textiles Llerena” was redesigned in the canton Pelileo, in the province of Tungurahua, based on the characterize of waste water. Through analytical method. It began for the recognition of each of the processes that develop in the laundry, which include washing and dyed clothing jean, then perform analysis of wastewater. Systematic sampling was used to replace data, starting from the design with which currently have the facilities of the laundry and finally every stage of the treatment was described. To characterize residual water from the stage of laundry textile processes Llerena, it was obtained as a result: 780mg/L of Chemical Oxygen Demand, 507 mg/L Biochemical Oxygen Demand, 447 mg/L sulfate, on which work was done in order to reduce pollution, because they do not comply with the established discharge limits in Unified Environmental Legislation Text. From wastewater should include: grids, sand trap tank, aerator trays and ozone treatment; to ensure that the tributary meets the parameters according the permissible limits of the existing standard of TULSMA Book VI Table 9. It is recommended that the head of operation and security of the company will involve actions toward the fulfillment of the plan of environmental handling with which the company has.es_ES
dc.language.isospaes_ES
dc.publisherEscuela Superior Politécnica de Chimborazoes_ES
dc.relation.ispartofseriesUDCTFC;236T0174-
dc.subjectREDISEÑO DE OPERACIONESes_ES
dc.subjectCARACTERIZACIÓN DEL EFLUENTEes_ES
dc.subjectDESCARGA DEL EFLUENTEes_ES
dc.subjectANÁLISIS DE AGUAS RESIDUALESes_ES
dc.subjectLÍMITES PERMISIBLESes_ES
dc.subjectEFLUENTEes_ES
dc.subjectLAVANDERIA DE ROPAes_ES
dc.subjectPELILEO (CANTÓN)es_ES
dc.titleRediseño de la planta de tratamiento de aguas residuales de la lavanderia “Procesos Textiles Llerena” del Cantón Pelileo, año 2015es_ES
dc.typebachelorThesises_ES
dc.contributor.miembrotribunalRamos, Marcelo-
Aparece en las colecciones: Ingeniero/a en Biotecnología Ambiental; Ingeniero/a Ambiental

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
236T0174.pdf3,43 MBAdobe PDFVista previa
Visualizar/Abrir


Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.