Por favor, use este identificador para citar o enlazar este ítem: http://dspace.espoch.edu.ec/handle/123456789/4757
Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.contributor.advisorVillacrés, Mario-
dc.contributor.authorLalaleo Camino, Maricela Fernanda-
dc.date.accessioned2016-05-19T21:13:08Z-
dc.date.available2016-05-19T21:13:08Z-
dc.date.issued2015-10-
dc.identifier.citationLalaleo Camino, Maricela Fernanda. (2015). Optimización de la Planta de Tratamiento de Agua Residual de la empresa Bioalimentar sector Pachanlica. Escuela Superior Politécnica de Chimborazo. Riobamba.es_ES
dc.identifier.urihttp://dspace.espoch.edu.ec/handle/123456789/4757-
dc.descriptionLa investigación se realizó para la Optimización de la Planta de Tratamiento de Agua Residual de la empresa Bioalimentar sector Pachanlica cantón Ambato. El estudio empezó por el reconocimiento del lugar, recolección y descarga del agua residual. Posteriormente se realizó la medición del caudal del efluente donde se tomó la muestra y datos, obteniendo el caudal de ingreso a la planta de tratamiento siendo este 1.16 m3/h, el proceso que realiza la planta para depurar el agua residual no es la más óptima ,consta de un sistema de lodos activado al cual se añadió bacterias a este efluente, conociendo que las bacterias propias del agua pueden realizar esta depuración, los flóculos formados pasaron a un sedimentador secundario en el cual caen al fondo de la cuba el agua clarificada pasa a un proceso de desinfección, y los lodos generados hacia un biodigestor. Al realizar la caracterización del agua se pudo observar que parámetros de Sólidos Suspendidos (113.5 mg/L) Demanda Bioquímica de Oxigeno (DBO) (480mg/L), Demanda Química de Oxigeno (DQO) (610 mg/L), Coliformes Totales, Coliformes Fecales se encuentra fuera de los límites permisibles de las normas del Texto Unificado de Legislación Ambiental (TULAS). Se concluyó que los parámetros analizados permitieron determinar los componentes del sistema de tratamiento para la optimización de recursos económicos, el mismo que contara adicionalmente con un sistemas de rejillas de operación manual, un tanque de Floculación- Coagulación y una dosis diferente del desinfectante para eliminar los agentes patógenos, logrando con esta la disminución de los límites establecidos tales como Sólidos Suspendidos (14 mg/L) Demanda Bioquímica de Oxigeno (DBO) (237 mg/L), Demanda Química de Oxigeno (DQO) (237 mg/L) Se recomienda a la Empresa Bioalimentar, implementar las rejillas, el tanque de Floculación- Coagulación, para el manejo y control de la contaminación de los efluentes líquidos que son descargados a la sequía aledaña.es_ES
dc.description.abstractThis research aimed to optimize the Wastewater Treatment Plant of Bioalimentar Company, in Pachanlica, in the city of Ambato. This study started recognizing the area collecting and discharging wastewater. Then, flow measurement where sample and data were taken, water - flow that comes in the plant is 1.16 m3 / h. Plant procedure to purify wastewater in not so optimum. It has an activated system for sludge and bacteria were added to this water – flow, because the bacteria are able to purify wastewater by themselves. Formed floaters were towards a secondary sedimentation tank, so purified water goes to the bottom and has a disinfestation process, and generated sludge goes to bio- manager tank. After water characterization, it was observed that parameters of Suspended Solids (113.5 mg/L) Biochemical Demand of Oxygen (BDO) (480mg/L), Chemical Demand of Oxygen (CDO) (610mg/L), Total Coliforms, Fecal Coliforms are over the limits according to Unified Text of Environmental Regulations (UTER). It was concluded that analyzed parameters allowed determining components of treatment system to optimize economic resources which will have a manual grid system, a Flocculation- Coagulation, and a different doses of disinfectant to eliminate the pathogen agent, so it is reached the reduction of established limist such as: Suspended Solids (14 mg/L) Biochemical Demand of Oxygen (BDO) (237 mg/L), Chemical Demand of Oxygen (CDO) (237mg/L). it is recommended to implemet grid, Flocculation – Coagulation tank in order to manage and control contamination of liquids that are discharged to the dry place next to Bioalimentar Company.es_ES
dc.language.isospaes_ES
dc.publisherEscuela Superior Politécnica de Chimborazo.es_ES
dc.relation.ispartofseriesUDCTFC;96T00320-
dc.subjectDEMANDA BIOQUÌMICA DE OXÌGENO [DBO]es_ES
dc.subjectDEMANDA QUÌMICA DE OXÌGENO [DQO]es_ES
dc.subjectFLOCULACIÒNes_ES
dc.subjectCOAGULACIÒNes_ES
dc.subjectBIOALIMENTADORes_ES
dc.subjectOPTIMIZACIÒNes_ES
dc.subjectAGUA RESIDUALes_ES
dc.subjectTEXTO UNIFICADO DE LEGISLACIÓN AMBIENTAL [TULAS]es_ES
dc.subjectINGENIERÍA QUÍMICAes_ES
dc.subjectAMBATO (CANTON)es_ES
dc.titleOptimización de la Planta de Tratamiento de Agua Residual de la empresa Bioalimentar sector Pachanlica.es_ES
dc.typebachelorThesises_ES
dc.contributor.miembrotribunalCalderón, Hugo-
Aparece en las colecciones: Ingeniero/a Químico/a

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
96T00320 UDCTFC.pdf3,19 MBAdobe PDFVista previa
Visualizar/Abrir


Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.