Por favor, use este identificador para citar o enlazar este ítem:
http://dspace.espoch.edu.ec/handle/123456789/4090
Registro completo de metadatos
Campo DC | Valor | Lengua/Idioma |
---|---|---|
dc.contributor.advisor | Yaulema, Fausto | - |
dc.contributor.author | Yaulema Bonilla, Alama Nicole | - |
dc.date.accessioned | 2015-10-12T21:32:14Z | - |
dc.date.available | 2015-10-12T21:32:14Z | - |
dc.date.issued | 2015-10-12 | - |
dc.identifier.uri | http://dspace.espoch.edu.ec/handle/123456789/4090 | - |
dc.description | Se dimensiono una Planta de Tratamiento de Aguas Residuales en la cabecera parroquial de Juan de Velasco cantón Colta provincia de Chimborazo para mejorar el medio ambiente y la vida de los pobladores. Se determinó caudales durante 7 días utilizando métodos volumétricos, obteniendo un caudal de diseño es 2.98 L/min. Para las caracterizaciones físicas, químicas y microbiológicas se efectuó muestreos durante 3 días empleando un muestreo compuesto en intervalo de 12 horas, dando como resultado valores de: pH (7,40 Und.); temperatura (10.1 °C) y nitratos (0,3 mg/L) encontrándose dentro de los límites permisibles; La conductividad; DQO; DBO5; fosfatos; sólidos totales; aceites y grasas; coliformes fecales y totales, no cumplen con los límites permisibles del TULSMA. Con los resultados de los análisis realizados se diseñó en software AUTOCAD, la Planta de Tratamiento de Aguas Residuales, la misma que consta de: canal de entrada, rejillas, tanque séptico, trampa de grasas y aceites, humedal artificial y tanque de desinfección y eras de secado. La remoción teórica del tanque séptico es: aceites y grasas 60 mg/L, DBO5 14,035 mg/L, sólidos suspendidos 287 mg/L y en el humedal artificial: DBO5 4.91 mg/L, DQO 23.6 mg/L, sólidos suspendidos 100 mg/L. Para la construcción se evidenció un lugar relativamente plano, cuyas coordenadas UTM son: 735705, 9797604, a una altura 3104 m.s.n.m, en las riberas del río Pangor y 3230 m.s.n.m de la comunidad, su área de implementación es 356.51 m2. La implementación de la Planta de Tratamiento de Aguas Residuales en las zonas rurales permite descontaminación ambiental y mejor calidad de vida de los seres vivos. Por lo que se recomienda la implementación de la planta, específicamente en la Cabecera Parroquial Juan de Velasco y en otras comunidades rurales. | es_ES |
dc.description.abstract | A Sewage Treatment Plant was built in Juan de Velasco Parish, Colta Canton, Chimbor azo determined during seven days by using volumetric methods resulting in a desing flow of 2.98 L/min. go t the physical, chemi ca l and microbiological characterizations some samples were taken during 3 days using a 12 - hour interval full sampling resulting i n the following values: pH(7,40 Und.); temperature (10.1ºC); and nitrates (0,3 mg/L), these are under the permissible limits; while DQO, DBO 5, phosphates, total solids, oil, fat, fecal a nd total coliforms are not under TULSMA permissible limits. The result s of the analysis were used to design the Sewage Treatment Plant with the use of AUTOCAD, which contains input channel, grids, septic tank, fat and oil trap, artificial humidity, disinfection tank and drying beds. The septic tank theoretical removal is: oi l and fat 60 mg/L, DBO 5 14. 035 mg/L, Suspended solids 28 7 mg/L, Artificial Humidity: DBO 5 4.91 mg/L, DQO 23.6 mg/L, Suspended solids 100 mg/L. Artificial Humidity: DBO 5 . For building the plant, it was necessary a relatively flat place which UTM coordinates are: 735705, 9797604, at a height of 3104 meters above sea level in Pangor river bank and 3230 meteres above sea level in the community, its area is 356,51 m 2 , The implementation of the Sewage Treatment Plant in rural areas decontaminate the environment and improve the quality of life of living being, that is why it is recommended to implement the Plant in Juan de Velasco Parish and other rural communities. | es_ES |
dc.language.iso | spa | es_ES |
dc.publisher | Escuela Superior Politécnica de Chimborazo | es_ES |
dc.relation.ispartofseries | UDCTFC;236T0137 | - |
dc.subject | PLANTA DE TRATAMIENTO DE AGUAS RESIDUALES | es_ES |
dc.subject | DESCONTAMINACIÓN AMBIENTAL | es_ES |
dc.title | Dimensionamiento de una Planta de tratamiento de Aguas Residuales para la Cabecera Parroquial de Juan de Velasco | es_ES |
dc.type | bachelorThesis | es_ES |
dc.contributor.miembrotribunal | Murillo, Mónica | - |
Aparece en las colecciones: | Ingeniero/a en Biotecnología Ambiental; Ingeniero/a Ambiental |
Ficheros en este ítem:
Fichero | Descripción | Tamaño | Formato | |
---|---|---|---|---|
236T0137 UDCTFCl.pdf | 6,27 MB | Adobe PDF | Visualizar/Abrir |
Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.