dc.identifier.citationGuadalupe Alcoser, María Augusta. (2014). Optimización del sistema de tratamiento de agua potable en la planta de San Juan Alto de la parroquia Matriz del Cantón Guamote. Escuela Superior Politécnica de Chimborazo. Riobamba.es_ES
dc.identifier.urihttp://dspace.espoch.edu.ec/handle/123456789/3512-
dc.descriptionSe realizó la Optimización del Sistema de Tratamiento de Agua Potable en la planta de San Juan Alto, perteneciente a la parroquia matriz del cantón Guamote, ubicada en la provincia de Chimborazo, con la finalidad de abastecer a la población de agua de calidad que garantice su salud y bienestar. Se realizaron análisis físico-químicos y microbiológicos de tres muestras durante un mes, en el Laboratorio Técnico de la ""Escuela Superior Politécnica de Chimborazo"" y en el Laboratorio de Servicios Ambientales de la ""Universidad Nacional de Chimborazo"", luego de esta caracterización se determinaron los parámetros que se encontraban fuera de los límites permisibles de acuerdo a la Norma Técnica Ecuatoriana NTE INEN 1108:2011 “Agua Potable. Requisitos”; siendo éstos: plomo y fosfatos; para la remoción de estos contaminantes se realizaron pruebas de jarras con un coagulante: el policloruro de aluminio. Después de encontrar la dosis adecuada de químico se logró la remoción de plomo y fosfatos en un 80 y 85% respectivamente, lo que indica que al aplicar el PAC el agua estará libre de contaminantes. Se realizaron los cálculos de ingeniería para encontrar la mejor opción de optimización de la planta, siendo la secuencia de las etapas la siguiente: mezcla rápida en vertedero rectangular, floculación, sedimentación, filtración y cloración, aunque en esta planta ya se contaba con sedimentación y cloración. Con los resultados obtenidos en las pruebas de tratabilidad se concluye que al realizar la optimización de la planta el agua que se distribuirá a la comunidad contará con características aceptables que permitan su consumo, es por eso que el Gobierno Autónomo Descentralizado Municipal del Cantón Guamote debe implementar este proyecto. Además es importante que todos los municipios mejoren o diseñen estos sistemas de tratamiento porque es su obligación dotar de un servicio de agua potable y segura a los habitanteses_ES
dc.description.abstractOptimization of the Drinking Water Treatment System at the San Juan Alto plant, belonging to the main parish of the Guamote canton, located in the province of Chimborazo, in order to supply the population with quality water that guarantees their health and well-being. Physical-chemical and microbiological analyses were performed on three samples during one month, at the Technical Laboratory of the ""Escuela Superior Politécnica de Chimborazo"" and at the Environmental Services Laboratory of the ""Universidad Nacional de Chimborazo"", after this characterization the parameters that were outside the permissible limits were determined according to the Ecuadorian Technical Standard NTE INEN 1108:2011 ""Drinking Water. Requirements""; being these: lead and phosphates; for the removal of these contaminants, jar tests were performed with a coagulant: aluminum polychloride. After finding the adequate dose of the chemical, lead and phosphate removal was achieved in 80 and 85% respectively, which indicates that when the PAC is applied, the water will be free of contaminants. Engineering calculations were made to find the best option for optimizing the plant, with the following sequence of stages: rapid mixing in a rectangular weir, flocculation, sedimentation, filtration and chlorination, although this plant already had sedimentation and chlorination. With the results obtained in the treatability tests, it is concluded that by optimizing the plant, the water that will be distributed to the community will have acceptable characteristics that allow its consumption, which is why the Autonomous Decentralized Municipal Government of Guamote Canton should implement this project. It is also important that all municipalities improve or design these treatment systems because it is their obligation to provide safe drinking water service to the inhabitants.es_ES
dc.language.isospaes_ES
dc.publisherEscuela Superior Politécnica de Chimborazoes_ES
dc.relation.ispartofseriesUDCTFC;96T00265-
dc.rightsinfo:eu-repo/semantics/openAccesses_ES
dc.subjectINGENIERÍA Y TECNOLOGÍA QUÍMICAes_ES
dc.subjectTRATAMIENTO DE AGUAes_ES
dc.subjectSISTEMA DE TRATAMIENTO DE AGUAes_ES
dc.subjectPLANTA DE AGUA POTABLEes_ES
dc.subjectPLANTA DE AGUA [SAN JUAN ALTO]es_ES
dc.subjectLA MATRIZ [PARROQUIA]es_ES
dc.subjectCANTÓN GUAMOTEes_ES
dc.subjectCHIMBORAZO [PROVINCIA]es_ES
dc.titleOptimización del sistema de tratamiento de agua potable en la planta de San Juan Alto de la parroquia Matriz del Cantón Guamotees_ES
dc.typebachelorThesises_ES
dc.contributor.miembrotribunalChuiza Rojas, Marco Raúl-
dc.rights.urihttps://creativecommons.org/licenses/by-nc-sa/3.0/ec/es_ES
Aparece en las colecciones: Ingeniero/a Químico/a

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
96T00265 UDCTFC.pdf4,79 MBAdobe PDFVista previa
Visualizar/Abrir


Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons Creative Commons