Por favor, use este identificador para citar o enlazar este ítem: http://dspace.espoch.edu.ec/handle/123456789/3409
Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.contributor.advisorUsiña, José-
dc.contributor.authorAbarca Bonilla, Elizabeth Mariela-
dc.date.accessioned2014-07-04T18:48:10Z-
dc.date.available2014-07-04T18:48:10Z-
dc.date.issued2014-07-04T18:48:10Z-
dc.identifier.citationAbarca Bonilla, Elizabeth Mariela. (2014). Diseño de un sistema de tratamiento para la potabilización del agua en la comunidad la Candelaria, parroquia San Luis. Escuela Superior Politécnica de Chimborazo. Riobamba.es_ES
dc.identifier.urihttp://dspace.espoch.edu.ec/handle/123456789/3409-
dc.descriptionLa presente investigación tiene por objetivo diseñar un sistema de tratamiento para potabilizar el agua en la Comunidad La Candelaria perteneciente a la Parroquia San Luis, Cantón Riobamba, Provincia de Chimborazo. Mediante los métodos cuantitativo y experimental, se estableció la caracterización inicial del agua a tratar, correspondiente a los análisis físico - químicos y microbiológicos, empleando técnicas espectrofométricas, volumétricas e instrumentales; a su vez, empleados para la recolección de muestras y realización de pruebas de jarras estableciendo la dosificación adecuada de cal y policloruro de aluminio, mismas que se efectuaron en el Laboratorio de Análisis Técnicos, Facultad de Ciencias, ESPOCH. De las caracterizaciones iniciales del agua, fueron identificados siete parámetros físico -químicos por encima de los límites permisibles conforme establece la Norma Técnica Ecuatoriana NTE INEN 1108:2011 “Agua Potable. Requisitos”, siendo éstos: turbiedad, dureza, calcio, magnesio, alcalinidad, bicarbonatos, fosfatos, en cuanto a los microbiológicos: coliformes totales y coliformes fecales. Se estableció el sistema de tratamiento adecuado, obteniéndose como resultado: turbiedad: 0,10 NTU, dureza: 80 mg/l, calcio: 16 mg/l, magnesio: 9,7 mg/l, alcalinidad: 200 mg/l, bicarbonatos: 204 mg/l, fosfatos: 0,16 mg/l, para coliformes totales y fecales, ausencia; cumpliendo con la normativa vigente. La planta de tratamiento se diseñó con un mezclador en vertedero rectangular de longitud: 0,69 m, ancho: 0,14 m, altura: 0,50 m; floculador hidráulico de flujo horizontal, longitud: 13,47 m, ancho: 4 m, profundidad: 0,10 m; sedimentador laminar, longitud: 1,35 m, ancho: 2,40 m, profundidad: 3 m; filtro rápido de arena, área: 2,03 m2, profundidad: 3,06 m; tanque intercambiador de cationes con capacidad: 2,50 m3, diámetro: 1,41 m; finalmente la desinfección será directamente en el tanque de almacenamiento con una capacidad de 5,56 m3. El tratamiento propuesto garantizará agua dees_ES
dc.description.abstractThe objective of this research is to design a water treatment system for the treatment of drinking water in the La Candelaria Community belonging to the San Luis Parish, Canton Riobamba, Province of Chimborazo. By means of quantitative and experimental methods, the initial characterization of the water to be treated was established, corresponding to the physical-chemical and microbiological analyses, using spectrophometric, volumetric and instrumental techniques; at the same time, samples were collected and jar tests were performed to establish the adequate dosage of lime and aluminum polychloride, which were carried out at the Technical Analysis Laboratory, Faculty of Sciences, ESPOCH. From the initial water characterizations, seven physical-chemical parameters were identified above the permissible limits as established by the Ecuadorian Technical Standard NTE INEN 1108:2011 "Drinking Water. Requirements", these being: turbidity, hardness, calcium, magnesium, alkalinity, bicarbonates, phosphates, and microbiological parameters: total coliforms and fecal coliforms. The appropriate treatment system was established and the results were: turbidity: 0.10 NTU, hardness: 80 mg/l, calcium: 16 mg/l, magnesium: 9.7 mg/l, alkalinity: 200 mg/l, bicarbonates: 204 mg/l, phosphates: 0.16 mg/l, for total and fecal coliforms, absence; complying with current regulations. The treatment plant was designed with a rectangular weir mixer, length: 0.69 m, width: 0.14 m, height: 0.50 m; horizontal flow hydraulic flocculator, length: 13.47 m, width: 4 m, depth: 0.10 m; lamellar settler, length: 1.35 m, width: 2.40 m, depth: 3 m; rapid sand filter, area: 2.03 m2, depth: 3.06 m; cation exchanger tank with capacity: 2.50 m3, diameter: 1.41 m; finally disinfection will be directly in the storage tank with a capacity of 5.56 m3. The proposed treatment will guarantee water ofes_ES
dc.language.isospaes_ES
dc.publisherEscuela Superior Politécnica de Chimborazoes_ES
dc.relation.ispartofseriesUDCTFC;96T00243-
dc.rightsinfo:eu-repo/semantics/openAccesses_ES
dc.subjectAGUA POTABLEes_ES
dc.subjectSISTEMA DE TRATAMIENTO DE AGUAes_ES
dc.subjectLA CANDELARIA (COMUNIDAD)es_ES
dc.subjectPROVINCIA DE CHIMBORAZOes_ES
dc.subjectRIOBAMBA [CANTÓN]es_ES
dc.subjectSAN LUIS (PARROQUIA)es_ES
dc.titleDiseño de un sistema de tratamiento para la potabilización del agua en la comunidad la Candelaria, parroquia San Luises_ES
dc.typebachelorThesises_ES
dc.contributor.miembrotribunalCalderón, Hugo Segundo-
dc.rights.urihttps://creativecommons.org/licenses/by-nc-sa/3.0/ec/es_ES
Aparece en las colecciones: Ingeniero/a Químico/a

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
96T00243.pdf3,36 MBAdobe PDFVista previa
Visualizar/Abrir


Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons Creative Commons