dc.identifier.citation | Berrones Zúñiga, Deysi Mariela. (2014). Diseño de un sistema de tratamiento de aguas residuales para la parroquia Sibambe. Escuela Superior Politécnica de Chimborazo. Riobamba. | es_ES |
dc.identifier.uri | http://dspace.espoch.edu.ec/handle/123456789/3200 | - |
dc.description | En la presente investigación se diseñó un sistema de tratamiento de aguas residuales para la Parroquia Sibambe del Cantón Alausí. Mediante el método deductivo, el estudio empezó por el reconocimiento del lugar de recolección y descarga del agua residual, luego se realizó la determinación del caudal del efluente mediante recipientes, termómetro y cronometro, donde se tomó muestras y datos, teniendo un caudal de diseño de 13.168 L/s, dato indispensable para la realización del diseño de la planta. Posteriormente aplicando el método experimental se obtuvo los resultados de análisis físico - químicos del efluente residual siendo, 577.50 mg/L de Demanda Química de Oxígeno, 372.7 mg/L de Demanda Bioquímica de Oxígeno, 20 ml/L Sólidos Sedimentales, 10 mg/L de Sólidos Suspensión, 170 Unidad Nefelométrica De Turbidez, 34.011x106 Unidades Formadoras de Colonias De Colifornmes Fecales, 4 mg/L Tensoactivos. Los parámetros mencionados se encuentran fuera de los límites permisibles de las normas del Texto Unificado de Legislación Ambiental. Se concluye que los parámetros analizados permitieron determinar los componentes del sistema de tratamiento, el mismo que constará de: rejillas, sedimentador circular primario, tanque de Lodos Activados, decantador circular secundario, y tanque de desinfección para tener un efluente que cumpla con los parámetros de acuerdo a los límites establecidos, por las normas del Texto Unificado de Legislación Ambiental. Recomiendo a la Junta Parroquial de Sibambe, implementar la planta de tratamiento, para manejo y control de la contaminación de los efluentes líquidos descargados al río Mallaguan. | es_ES |
dc.description.abstract | In the present investigation, a wastewater treatment system was designed for the Sibambe Parish of the Alausí Canton. Using the deductive method, the study began with the recognition of the place of collection and discharge of wastewater, then the effluent flow was determined by means of containers, thermometer and chronometer, where samples and data were taken, having a design flow of 13,168 L/s, essential data for the realization of the plant design. Subsequently, applying the experimental method, the results of the physical-chemical analysis of the residual effluent were obtained: 577.50 mg/L of Chemical Oxygen Demand, 372.7 mg/L of Biochemical Oxygen Demand, 20 ml/L Sediment Solids, 10 mg/L of Suspension Solids, 170 Nephelometric Turbidity Unit, 34.011x106 Colony Forming Units of Fecal Colifornmes, 4 mg/L Tensoactives. The aforementioned parameters are outside the permissible limits of the standards of the Unified Text of Environmental Legislation. It is concluded that the parameters analyzed allowed to determine the components of the treatment system, which will consist of: grids, primary circular settler, activated sludge tank, secondary circular decanter, and disinfection tank to have an effluent that meets the parameters according to the limits established by the standards of the Unified Text of Environmental Legislation. I recommend that the Sibambe Parish Council implement the treatment plant to manage and control the contamination of liquid effluents discharged into the Mallaguan River. | es_ES |
dc.language.iso | spa | es_ES |
dc.publisher | Escuela Superior Politécnica de Chimborazo | es_ES |
dc.relation.ispartofseries | UDCTFC;96T00234 | - |
dc.rights | info:eu-repo/semantics/openAccess | es_ES |
dc.subject | AGUAS RESIDUALES | es_ES |
dc.subject | TRATAMIENTO DE AGUAS RESIDUALES | es_ES |
dc.subject | SISTEMAS DE TRATAMIENTO DE AGUAS RESIDUALES | es_ES |
dc.subject | PROVINCIA DE CHIMBORAZO | es_ES |
dc.subject | DISEÑO DE SISTEMAS DE TRATAMIENTO DE AGUAS RESIDUALES | es_ES |
dc.subject | SIBAMBE (PARROQUIA) | es_ES |
dc.title | Diseño de un sistema de tratamiento de aguas residuales para la parroquia Sibambe | es_ES |
dc.type | bachelorThesis | es_ES |
dc.contributor.miembrotribunal | Chuiza Rojas, Marco Raúl | - |
dc.rights.uri | https://creativecommons.org/licenses/by-nc-sa/3.0/ec/ | es_ES |
Aparece en las colecciones: | Ingeniero/a Químico/a |
Ficheros en este ítem:
Fichero | Descripción | Tamaño | Formato | |
---|---|---|---|---|
96T00234.pdf | 3,69 MB | Adobe PDF | Visualizar/Abrir |
Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons