dc.identifier.citation | Demera Charcopa, Juan José. (2014). Optimización del tratamiento del agua de alimentación de calderas de la Empresa Contrachapados de Esmeraldas S.A. Escuela Superior Politécnica de Chimborazo. Riobamba. | es_ES |
dc.identifier.uri | http://dspace.espoch.edu.ec/handle/123456789/3112 | - |
dc.description | La optimización del tratamiento del agua de alimentación de calderas de la Empresa Contrachapados de Esmeraldas S.A, de la ciudad de Esmeraldas tiene como finalidad cumplir con todos los parámetros exigidos por normas técnicas de calderas. El método experimental fue utilizado para la investigación con fines evaluativos, para el análisis del agua alimentación de calderas se realizaron mediciones in situ y en el laboratorio de la empresa utilizando equipos como: conductímetro, pHmetro, termómetros, colorímetros. Las técnicas y material de laboratorio se basaron en métodos normalizados de la American Society For Testing And Materials(ASTM) y los Standard Methods (SM). La regeneración de la resina utilizada en el ablandador con el uso de cloruro de sodio al 20% en solución, tiempo entre regeneraciones cada dos días, aplicación estricto de purgas y reducción de dureza mediante el uso del producto químico Nexguard 22300 fueron variables claves para mejorar la calidad del agua. Como resultado la dureza pasó de 12,6ppm a 0,5 ppm cuyo valor es corregido hasta un valor de cero mediante la adición de Nexguard 22300, la cantidad de sólidos totales disueltos pasan de 255,83ppm a 100ppm, mientras la conductividad pasa de 511,67µS/cm a 200 µS/cm. Como conclusión, la calidad del agua de alimentación de calderas optimizada cumple con los parámetros que exige la norma del catálogo. Se recomienda el control diario de parámetros del agua, la aplicación de purgas necesarias, la dosificación correcta de productos químicos y la regeneración con solución decloruro de sodio al 20% para mejorar el ablandamiento. | es_ES |
dc.description.abstract | The optimization of boiler feed water treatment at Contrachapados de Esmeraldas S.A. in the city of Esmeraldas is aimed at complying with all the parameters required by boiler technical standards. The experimental method was used for the research with evaluative purposes. For the analysis of the boiler feed water, measurements were made in situ and in the company's laboratory using equipment such as: conductivity meter, pH meter, thermometers, colorimeters. The laboratory techniques and materials were based on standardized methods of the American Society For Testing And Materials (ASTM) and Standard Methods (SM). The regeneration of the resin used in the softener with the use of 20% sodium chloride in solution, time between regenerations every two days, strict application of purges and reduction of hardness through the use of the chemical Nexguard 22300 were key variables to improve water quality. As a result, hardness went from 12.6ppm to 0.5ppm which is corrected to a value of zero by the addition of Nexguard 22300, total dissolved solids went from 255.83ppm to 100ppm, while conductivity went from 511.67µS/cm to 200 µS/cm. In conclusion, the optimized boiler feedwater quality meets the parameters required by the catalog standard. Daily monitoring of water parameters, application of necessary blowdowns, correct dosing of chemicals and regeneration with 20% sodium dechloride solution to improve softening are recommended. | es_ES |
dc.language.iso | spa | es_ES |
dc.publisher | Escuela Superior Politécnica de Chimborazo | es_ES |
dc.relation.ispartofseries | UDCTFC;96T00231 | - |
dc.rights | info:eu-repo/semantics/openAccess | es_ES |
dc.subject | OPTIMIZACIÓN | es_ES |
dc.subject | TRATAMIENTO DE AGUA | es_ES |
dc.subject | CALDERAS | es_ES |
dc.subject | AGUA DE ALIMENTACIÓN DE CALDERAS | es_ES |
dc.title | Optimización del tratamiento del agua de alimentación de calderas de la Empresa Contrachapados de Esmeraldas S.A. | es_ES |
dc.type | bachelorThesis | es_ES |
dc.contributor.miembrotribunal | Chuiza, Marco | - |
dc.rights.uri | https://creativecommons.org/licenses/by-nc-sa/3.0/ec/ | es_ES |
Aparece en las colecciones: | Ingeniero/a Químico/a |
Ficheros en este ítem:
Fichero | Descripción | Tamaño | Formato | |
---|---|---|---|---|
96T00231.pdf | 1,44 MB | Adobe PDF | Visualizar/Abrir |
Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons