Por favor, use este identificador para citar o enlazar este ítem:
http://dspace.espoch.edu.ec/handle/123456789/22822
Registro completo de metadatos
Campo DC | Valor | Lengua/Idioma |
---|---|---|
dc.contributor.advisor | Bolaños Logroño, Paulina Fernanda | - |
dc.contributor.author | Charicando Sayay, Luis Avelino | - |
dc.date.accessioned | 2024-09-11T17:23:51Z | - |
dc.date.available | 2024-09-11T17:23:51Z | - |
dc.date.issued | 2023-12-05 | - |
dc.identifier.citation | Charicando Sayay, Luis Avelino. (2024). Evaluación de calidad del agua de consumo de fuentes de abastecimiento de la parroquia Juan de Velasco. Escuela Superior Politécnica de Chimborazo. Riobamba. | es_ES |
dc.identifier.uri | http://dspace.espoch.edu.ec/handle/123456789/22822 | - |
dc.description | Si bien la parroquia Juan de Velasco cuenta con suficientes suministros de aguas, carece de tanques de captaciones adecuados que permitan almacenar el recurso correctamente. Además, enfrentar amenazas de deslaves en invierno, el pastoreo y la siembra de cultivos cerca de las fuentes. Para abordar esta problemática el objetivo de la presente investigación fue evaluar la calidad del agua de consumo de fuentes de abastecimiento de la parroquia Juan de Velasco. La metodología implementada tuvo un enforque descriptivo, cualitativo, cuantitativo y exploratorio, mientras que el diseño de la investigación fue no experimental debido a que las variables no fueron manipuladas intencionalmente para relacionar los parámetros de análisis. La evaluación se llevó a cabo mensualmente, durante el periodo de mayo a julio de 2023. Se examinaron tres tanques de captaciones, un tanque de almacenamiento y distribución, domicilio más cercano y lejano. En estas ubicaciones, se observaron y midieron las mismas variables de estudio, que incluyeron parámetros fisicoquímicos y microbiológicos. Mediante la metodología empleada se logró determinar la contaminación en el tanque de captación tres, en donde parámetros como sólidos disueltos totales con promedios de mayo (169,3 mg/L) y julio (161 mg/L), coliformes fecales con promedios de mayo (106,67 UFC/100 ml) y julio (60,5 UFC/100 ml) y coliformes totales con promedios de mayo (222,5 UFC/100 ml) y julio (150 UFC/100 ml), superaron los valores de referencia del reglamento técnico NTE INEN 1108 sexta revisión. A pesar de la contaminación en dicho tanque, los resultados obtenidos en el resto de los tanques se encontraron dentro del rango de niveles de aceptabilidad de la calidad del agua. En este contexto se concluye que el agua en las captaciones sigue siendo apta como fuente de consumo, pero se destaca la necesidad de implementar un plan de medidas de control y seguridad. | es_ES |
dc.description.abstract | Although Juan de Velasco town has sufficient water supplies, it lacks adequate catchment tanks to store the resources properly. In addition, it faces threats of landslides in winter, grazing, and crop planting near the sources. To address this problem, this research aimed to evaluate the quality of drinking water from water supply sources at Juan de Velasco town. The methodology implemented had a descriptive, qualitative, quantitative, and exploratory approach, while the research design was non-experimental because the variables were not intentionally manipulated concerning the parameters of the analysis. The evaluation was carried out monthly, during the period from May to July 2023. Three catchment tanks and one storage and distribution tank were examined in the nearest and farthest locations. At these locations, the same study variables, including physicochemical and microbiological parameters, were observed and measured. The methodology was used to determine contamination in catchment tank three, where parameters such as total dissolved solids exceeded the reference values of technical regulation NTE INEN 1108 sixth revision. The contamination had averages in May (169.3 mg/L) and July (161 mg/L), fecal coliforms with averages in May (106.67 CFU/100 ml) and July (60.5 CFU/100 ml), and total coliforms with averages in May (222.5 CFU/100 ml) and July (150 CFU/100 ml). Despite the contamination in this tank, the results obtained in the rest of the tanks were within the range of acceptable water quality levels. In this context, it is concluded that the water in the catchments is still suitable as a source of consumption, but the need to implement a plan of control and safety measures is highlighted. | es_ES |
dc.language.iso | spa | es_ES |
dc.publisher | Escuela Superior Politécnica de Chimborazo | es_ES |
dc.relation.ispartofseries | UDCTFC;236T0955 | - |
dc.rights | info:eu-repo/semantics/openAccess | es_ES |
dc.subject | CALIDAD DE AGUA | es_ES |
dc.subject | AGUA POTABLE | es_ES |
dc.subject | PARÁMETROS MICROBIOLÓGICOS | es_ES |
dc.subject | PARÁMETROS FÍSICOS | es_ES |
dc.subject | PARÁMETROS QUÍMICOS | es_ES |
dc.title | Evaluación de calidad del agua de consumo de fuentes de abastecimiento de la parroquia Juan de Velasco | es_ES |
dc.type | info:eu-repo/semantics/bachelorThesis | es_ES |
dc.contributor.miembrotribunal | Nuñez Moreno, María Soledad | - |
dc.rights.uri | https://creativecommons.org/licenses/by-nc-sa/3.0/ec/ | es_ES |
Aparece en las colecciones: | Ingeniero/a en Biotecnología Ambiental; Ingeniero/a Ambiental |
Ficheros en este ítem:
Fichero | Descripción | Tamaño | Formato | |
---|---|---|---|---|
236T0955.pdf | 2,44 MB | Adobe PDF | Visualizar/Abrir |
Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons