Por favor, use este identificador para citar o enlazar este ítem: http://dspace.espoch.edu.ec/handle/123456789/21834
Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.contributor.advisorGuamán Lozada, Dario Fernando-
dc.contributor.authorSantacruz Solis, Patricio Giovanny  -
dc.date.accessioned2024-06-26T17:24:22Z-
dc.date.available2024-06-26T17:24:22Z-
dc.date.issued2023-11-22-
dc.identifier.citationSantacruz Solis, Patricio Giovanny. (2023). Modelado de una reacción exotérmica en tanque agitado aplicando dinámica computacional de fluidos para la detección de posibles fugas térmicas. Escuela Superior Politécnica de Chimborazo. Riobambaes_ES
dc.identifier.urihttp://dspace.espoch.edu.ec/handle/123456789/21834-
dc.descriptionEl presente trabajo de Integración Curricular tuvo como objetivo el desarrollo de un modelado, utilizando un software CFD, de una reacción exotérmica en tanque agitado aplicando dinámica computacional de fluidos para la detección de posibles fugas térmicas, debido a que su presencia podría conducir potencialmente a accidentes dentro del reactor. Se realizó un análisis de las variables y parámetros de la esterificación del 2 butanol con anhídrido propanoico para determinar los criterios y las operaciones necesarias para la simulación de la reacción. Además, se desarrolló 3 tipos de modelados de la misma reacción en 3 diferentes dimensiones: 1D, 2D y 3D. Mediante referencias bibliográficas de alto impacto, se comprobó y validó la simulación con los resultados obtenidos muy similares de las variables de temperatura y tiempo siendo éste último en el que ocurren dichas fugas térmicas. En los modelados 1D y 2D se obtuvieron resultados de fugas térmicas con temperaturas máximas de 130 ℃ y 127 ℃ respectivamente, mientras que según Rudniak et al. 2004, para los modelados 0D y 2D las temperaturas máximas de las fugas térmicas fueron 133 ℃ y 129 ℃. Así mismo, en el modelado 3D desarrollado, la temperatura más alta registrada de fugas térmicas es de 113 ℃, por otra parte en Rudniak et al. 2004 el pico más alto de temperatura es de 111 ℃. Gracias a este proceso de validación, se añadió credibilidad a los resultados, reforzando la precisión de las metodologías de simulación empleadas, tambien se concluyó que el modelado 3D es la opción más conveniente y realista para un sistema de detección de fugas térmicas debido a que considera todos los factores y parámetros relevantes de los sistemas de tanques agitados del mundo real, debido a que mostró una similitud sustancial con los hallazgos experimentales y el modelo híbrido 2D/3D de Rudniak et al. 2004.es_ES
dc.description.abstractThe present Curricular Integration work dealt with the development of a modeling, using CFD software, of an exothermic reaction in a stirred tank applying computational fluid dynamics for the detection of possible thermal leaks, because their presence could potentially lead to accidents inside the reactor. An analysis of the variables and parameters of the esterification of 2-butanol with propane anhydride was carried out to determine the criteria and operations necessary for the simulation of the reaction. In addition, 3 types of modeling of the same reaction were developed in 3 different dimensions: 1D, 2D and 3D. By means of high impact bibliographic references, the simulation was checked and validated with very similar results obtained for the temperature and time variables, the latter being the one in which these thermal leaks occur. In the 1D and 2D modeling, thermal leakage results were obtained with maximum temperatures of 130 ℃ and 127 ℃ respectively, while according to Rudniak et al. 2004, for the 0D and 2D modeling the maximum temperatures of thermal leakage were 133 ℃ and 129 ℃. Likewise, in the developed 3D modeling, the highest recorded thermal leakage temperature is 113 ℃, on the other hand in Rudniak et al. 2004 the highest peak temperature is 111 ℃. Thanks to this validation process, credibility was added to the results, reinforcing the accuracy of the simulation methodologies employed, it was also concluded that 3D modeling is the most convenient and realistic option for a thermal leak detection system because it considers all relevant factors and parameters of real world agitated tank systems, due to the fact that it showed substantial similarity with the experimental findings and the hybrid 2D/3D model of Rudniak et al. 2004.es_ES
dc.language.isospaes_ES
dc.publisherEscuela Superior Politécnica de Chimborazoes_ES
dc.relation.ispartofseriesUDCTFC;96T00970-
dc.rightsinfo:eu-repo/semantics/openAccesses_ES
dc.subjectSOFTWARE CFDes_ES
dc.subjectESTERIFICACIÓNes_ES
dc.subjectFUGAS TÉRMICASes_ES
dc.subjectMODELADOes_ES
dc.subjectREACTORes_ES
dc.subjectMODELO HÍBRIDOes_ES
dc.titleModelado de una reacción exotérmica en tanque agitado aplicando dinámica computacional de fluidos para la detección de posibles fugas térmicases_ES
dc.typeinfo:eu-repo/semantics/bachelorThesises_ES
dc.contributor.miembrotribunalChuquin Vasco, Daniel Antonio-
dc.rights.urihttps://creativecommons.org/licenses/by-nc-sa/3.0/ec/es_ES
Aparece en las colecciones: Ingeniero/a Químico/a

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
96T00970.pdf1,02 MBAdobe PDFVista previa
Visualizar/Abrir


Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons Creative Commons