Campo DC | Valor | Lengua/Idioma |
---|---|---|
dc.contributor.advisor | Cabrera Aguayo, Fausto Ramiro | - |
dc.contributor.author | Tamami Tamami, Carlos Mauricio | - |
dc.date.accessioned | 2024-06-17T16:09:56Z | - |
dc.date.available | 2024-06-17T16:09:56Z | - |
dc.date.issued | 2020-09-14 | - |
dc.identifier.citation | Tamami Tamami, Carlos Mauricio. (2020). Implementación del banco automático de capacitores para la corrección del factor de potencia en la planta de producción El Salinerito. Escuela Superior Politécnica de Chimborazo. Riobamba. | es_ES |
dc.identifier.uri | http://dspace.espoch.edu.ec/handle/123456789/21659 | - |
dc.description | El objetivo del presente trabajo de titulación fue elevar el factor de potencia a través de la implementación y diseño del banco automático de condensadores el cual es capaz de controlar la demanda de potencia reactiva requerida por el sistema eléctrico. Para realizar la implementación fue necesario realizar mediciones de los parámetros eléctricos, para lo cual se procedió a hacer uso del analizador de energía trifásico FLUKE 435 SERIES II, el cual fue instalado en las terminales del tablero de distribución principal, el periodo de medición fue de 7 días, 168 horas continuas tomando muestras cada 10 minutos según lo estipulado en la regulación ARCONEL 005/18. Los parámetros obtenidos fueron: voltajes fase, corriente fase, potencia activa, reactiva, aparente, factor de potencia, armónicos de corriente y de voltaje, distorsión armónica total de corriente y voltaje. El análisis de los parámetros eléctricos obtenidos indica que la fábrica el Salinerito tiene bajo factor de potencia y es ineficiente en la distribución de energía eléctrica. Por esta razón, se procedió a realizar el mantenimiento del tablero eléctrico principal, mantenimiento de los tableros eléctricos secundarios, la instalación de puesta a tierra que permita descargar las corrientes armónicas, corrección de las instalaciones eléctricas mal hechas, correcto dimensionamiento del conductor, el balance de cargas, análisis de caídas de voltaje y cargabilidad de los conductores debido al mal funcionamiento en diferentes áreas de la fábrica, cambio de conductores con recubrimiento defectuoso y sobrecalentados. El mantenimiento realizado y la implementación del banco automático de condensadores disminuye las pérdidas de energía en los conductores, reduce las caídas de tensión, aumenta la disponibilidad de potencia en los transformadores e incrementa la vida útil de las instalaciones. | es_ES |
dc.description.abstract | The aim of this research was to increase the power factor through the implementation and design of an automatic capacitor bank capable of controlling the reactive power demand required by the electrical system. To carry out the execution, it was necessary to perform measurements of electrical parameters. We proceeded to make use of the three-phase energy analyzer FLUKE 435 SERIES II, which was installed at the terminals of the main distribution board. The measurement period was seven days, 168 continuous hours taking samples every 10 minutes as stipulated in the regulation ARCONEL 005/18. The parameters obtained were: phase voltages, phase current, active, reactive and apparent power, power factor, current and voltage harmonics, total harmonic distortion of current and voltage. The electrical parameters analysis obtained, indicates that the “Salinerito” factory has a low power factor and is inadequate in the distribution of electrical energy. For this reason, we proceeded to perform maintenance of the main electrical panel, maintenance of the alternate electrical panels, installation of grounding to discharge harmonic currents, correction of poor electrical installations, correct conductor sizing, load balancing, analysis of voltage drops and loadability of the conductors due to bad performance in different areas of the factory, replacement of conductors with defective coating and overheated conductors. The maintenance performed and the automatic capacitor bank´s implementation reduces energy losses in the conductors, reduces voltage drops, increases power availability in the transformers and increases the installations´useful life. | es_ES |
dc.language.iso | spa | es_ES |
dc.publisher | Escuela Superior Politécnica de Chimborazo | es_ES |
dc.relation.ispartofseries | UDCTFIYE;108T0346 | - |
dc.rights | info:eu-repo/semantics/openAccess | es_ES |
dc.subject | CALIDAD DE LA ENERGÍA | es_ES |
dc.subject | CORRECCIÓN DEL FACTOR DE POTENCIA | es_ES |
dc.subject | BANCO AUTOMÁTICO | es_ES |
dc.subject | CONTROLADOR DE FACTOR DE POTENCIA | es_ES |
dc.subject | POTENCIA REACTIVA | es_ES |
dc.subject | CARGA INDUSTRIAL | es_ES |
dc.subject | CARGA INDUCTIVA | es_ES |
dc.title | Implementación del banco automático de capacitores para la corrección del factor de potencia en la planta de producción El Salinerito. | es_ES |
dc.type | info:eu-repo/semantics/bachelorThesis | es_ES |
dc.contributor.miembrotribunal | Viteri Barrera, Marco Antonio | - |
dc.rights.uri | https://creativecommons.org/licenses/by-nc-sa/3.0/ec/ | es_ES |