Por favor, use este identificador para citar o enlazar este ítem: http://dspace.espoch.edu.ec/handle/123456789/21463
Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.contributor.advisorBravo Morocho, Víctor David-
dc.contributor.authorPilamunga Salazar, Denys Luis-
dc.date.accessioned2024-06-11T20:10:59Z-
dc.date.available2024-06-11T20:10:59Z-
dc.date.issued2023-11-11-
dc.identifier.citationPilamunga Salazar, Denys Luis. (2023). Diseño de un plan de mantenimiento preventivo programado para la flota de ambulancias ancladas al SIS ECU 911 de la ciudad de Riobamba, creando un software de mantenimiento para optimizar los procesos. Escuela Superior Politécnica de Chimborazo. Riobamba.es_ES
dc.identifier.urihttp://dspace.espoch.edu.ec/handle/123456789/21463-
dc.descriptionEn el presente trabajo técnico se diseñó un plan de mantenimiento preventivo mediante la implementación de un software en la institución Ministerio de Salud Pública anclada al SIS ECU 911 de Riobamba que brinda servicio de emergencia a la ciudadanía. El plan de mantenimiento tiene como objetivo garantizar que las unidades de ambulancias trabajarán en óptimas condiciones al momento de atender un incidente. Un plan de mantenimiento provee ventajas sobre la sociedad y funcionarios que trabajan allí como una mayor seguridad ante una emergencia, reducción de tiempos de inactividad y ahorro monetario para la institución. Se recopiló información de las diferentes fallas que ha tenido en los últimos años las unidades de emergencia, una vez estudiadas se estableció un punto de partida mediante encuestas para establecer el estado de funcionalidad actual que se encuentran las unidades móviles prehospitalarias; así como los respectivos mantenimientos que se han realizado. Posterior a ello se procedió a la implementación del software computacional en SASM para llevar a cabo el control y los respectivos mantenimientos en las ambulancias; reduciendo el tiempo de generación de ordenes de trabajo, que son enviadas al respectivo taller autorizado para su corrección, avalando la efectividad y el correcto rendimiento, alargando la vida útil de sus componentes, ayudando a disminuir los costos de mantenimientos y tiempos de parada. Posterior a ello se evaluó una segunda encuesta sobre el plan de mantenimiento y la instrucción para afirmar efectividad en la institución, del 80% de unidades de ambulancias que estaban inoperativas por falta de mantenimiento, el 50% se logró ponerlas en operatividad, resaltando una mejor gestión y una entrega de informe para realizar el proceso respectivo de mantenimiento correctivo. En base al resultado se concluye que tanto para el personal como para las unidades móviles es de ayuda el proyecto en términos generales.es_ES
dc.description.abstractIn this technical work a preventive maintenance plan is designed through the implementation of a software at Ministerio de Salud Pública anchored to the SIS ECU 911 of Riobamba that provides emergency service to citizens. The maintenance plan aims to ensure that the ambulance units will work in optimal conditions at the time of responding to an incident. A maintenance plan provides advantages for the society and officials who work there, such as greater safety to an emergency, reduced downtime, and monetary savings for the institution. Information was compiled on the different failures that the emergency units have had in recent years. Once they had been studied, a starting point was established through surveys to establish the current state of functionality of the prehospital mobile units, as well as the respective maintenance that has been carried out. Subsequently, we proceeded to the implementation of computer software in SASM to carry out the control and the respective maintenance in ambulances, reducing the time of generation of work orders, which are sent to the respective authorized workshop for correction, ensuring the effectiveness and proper performance, extending the life of its components, helping to maintenance costs and downtime. After this, a second survey on the maintenance plan and the instruction to affirm effectiveness in the institution was evaluated. Of the 80% of ambulance units that were inoperative due to lack of maintenance, 50% were put into operation, highlighting better management and delivery of the report to carry out the respective corrective maintenance process. Based on the results, it can be concluded that the project is helpful for both the personnel and the mobile units in general terms.es_ES
dc.language.isospaes_ES
dc.publisherEscuela Superior Politécnica de Chimborazoes_ES
dc.relation.ispartofseriesUDCTFM;65T00521-
dc.rightsinfo:eu-repo/semantics/openAccesses_ES
dc.subjectTECNOLOGÍA Y CIENCIAS DE LA INGENIERÍAes_ES
dc.subjectPLAN DE MANTENIMIENTO PREVENTIVOes_ES
dc.subjectAMBULANCIAes_ES
dc.subjectGESTIÓN DE MANTENIMIENTOes_ES
dc.subjectSISTEMA DE ATENCIÓN DE SALUD Y ATENCIÓN MÓVIL (SASM)es_ES
dc.subjectOPERATIVIDADes_ES
dc.titleDiseño de un plan de mantenimiento preventivo programado para la flota de ambulancias ancladas al SIS ECU 911 de la ciudad de Riobamba, creando un software de mantenimiento para optimizar los procesoses_ES
dc.typeinfo:eu-repo/semantics/bachelorThesises_ES
dc.contributor.miembrotribunalSánchez Carrión, Edgar Fabián-
dc.rights.urihttps://creativecommons.org/licenses/by-nc-sa/3.0/ec/es_ES
Aparece en las colecciones: Ingeniero Automotriz

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
65T00521.pdf2,76 MBAdobe PDFVista previa
Visualizar/Abrir


Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons Creative Commons