dc.identifier.citation | Londo Pérez, Alvaro Fabián. (2022). Diseño e implementación de una prótesis del miembro inferior derecho para una persona con amputación transtibial. Escuela Superior Politécnica de Chimborazo. Riobamba. | es_ES |
dc.identifier.uri | http://dspace.espoch.edu.ec/handle/123456789/21457 | - |
dc.description | El presente trabajo de titulación tuvo como objetivo el diseño e implementación de una prótesis del miembro inferior derecho para una persona con amputación transtibial. El diseño consta de dos partes una mecánica que está compuesta por el encaje (socket), pilón y tobillo-pie que proporcionan una marcha segura y amortiguada al usuario; y otra electrónica encargada de controlar la cantidad de aire que ingresa a la vejiga de aire ubicada entre el muñón y el encaje por medio de una bomba, válvula y un sensor de presión. La tarjeta Arduino se encargó de procesar los datos que llegan desde el sensor de presión para activar la bomba y válvula según sea la condición asignada. El diseño y simulación del tobillo-pie fue realizado en el programa Autodesk Inventor de este se genera un archivo .stl necesario para configurar los parámetros de impresión en el programa Cura y transformarlos a código G que es el lenguaje que entiende la impresora 3D. Como resultados de las pruebas, se determinó que la presión en la vejiga de aire para un buen ajuste con el muñón es alrededor de los 30kPa y la carga que se debe aplicar al tobillo-pie debe ser menor a 735 N. Se concluye que al aplicar una carga mayor a la establecida el prototipo presenta fisuras que pueden ser corregidas con resortes y la suspensión por medio de la vejiga aire debe ser de un material más cómodo para el usuario. Se recomienda no fiarse únicamente en los resultados de la simulación para el diseño final. | es_ES |
dc.description.abstract | The objective of this degree work was the design and implementation of a lower right limb prosthesis for a person with transtibial amputation. The design consists of two parts, a mechanism that is made up of the socket, pylon and ankle-foot that provide a safe and cushioned ride to the user; and other electronics in charge of controlling the amount of air that enters the air bladder located between the stump and the socket by means of a pump, a valve, and a pressure sensor. The Arduino card processed the data originated from the pressure sensor to activate the pump and valve according to the assigned condition. The design and simulation of the ankle-foot was carried out in the Autodesk Inventor program, from which an .stl file is generated, necessary to configure the printing parameters in the Cura program and transform them into G code, which is the language that the 3D printer understands. As a result of the tests, it was determined that the pressure in the air bladder for a good fit with the stump is around 30kPa and the load that must be applied to the ankle-foot must be less than 735 N. It is concluded that when applying a load greater than the established, the prototype has cracks that can be corrected with springs; and the suspension by means of the air bladder must be made of a more comfortable material for the user. It is recommended not to rely solely on the simulation results for the final design. | es_ES |
dc.language.iso | spa | es_ES |
dc.publisher | Escuela Superior Politécnica de Chimborazo | es_ES |
dc.relation.ispartofseries | UDCTFIYE;108T0449 | - |
dc.rights | info:eu-repo/semantics/openAccess | es_ES |
dc.subject | SISTEMA APSS | es_ES |
dc.subject | DISEÑO MECÁNICO | es_ES |
dc.subject | PRÓTESIS TRANSTIBIAL | es_ES |
dc.subject | INGENIERÍA ASISTIDA POR COMPUTADORA | es_ES |
dc.subject | IMPRESIÓN 3D | es_ES |
dc.title | Diseño e implementación de una prótesis del miembro inferior derecho para una persona con amputación transtibial. | es_ES |
dc.type | info:eu-repo/semantics/bachelorThesis | es_ES |
dc.contributor.miembrotribunal | Viteri Barrera, Marco Antonio | - |
dc.rights.uri | https://creativecommons.org/licenses/by-nc-sa/3.0/ec/ | es_ES |
Aparece en las colecciones: | Ingeniero en Electrónica, Control y Redes Industriales; Ingeniero/a en Electrónica y Automatización |
Ficheros en este ítem:
Fichero | Descripción | Tamaño | Formato | |
---|---|---|---|---|
108T0449.pdf | 1,9 MB | Adobe PDF | Visualizar/Abrir |
Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons