dc.date.issued | 2022-05-19 | - |
dc.identifier.citation | Soldado Guamán, Joaquín Rosendo. (2022). Análisis del rendimiento de sistemas de conversión DC-DC MISO aislado y no aislado en lazo cerrado basado en controladores clásicos bajo un entorno de producción de energía renovable híbrida mediante el diseño, modelado y simulación. Escuela Superior Politécnica de Chimborazo. Riobamba. | es_ES |
dc.identifier.uri | http://dspace.espoch.edu.ec/handle/123456789/21446 | - |
dc.description | El objetivo de la presente investigación fue analizar el rendimiento de sistemas de conversión de corriente directa a corriente directa (DC-DC) de múltiples entradas y salida única (MISO) aislado y no aislado en lazo cerrado, basado en controladores clásicos bajo un entorno de producción de energía renovable híbrida mediante el diseño, modelado y simulación. La investigación partió de una revisión del estado del arte acerca de estos sistemas, producto del cual se dedujo las estrategias de diseño propuestas por los diferentes autores; y conforme a esta se planteó los diferentes casos de estudio como: El convertidor Reductor, Elevador-Reductor, Flyback y Forward, estos dos últimos correspondientes a la arquitectura aislada. De cada uno de estos se obtuvo la caracterización y se estableció los criterios de dimensionamiento bajo la metodología de análisis ideal basada en el voltaje y corriente de la bobina. Sin embargo, para el análisis de efectos no ideales, modelado y control en lazo cerrado se tomó como representante al convertidor reductor y al convertidor Flyback. Establecido el análisis de los convertidores la investigación se centró en diseñar e implementar el entono de producción de energía renovable hibrida en lazo cerrado sobre el cual iban a ser evaluados los modelos propuestos. Bajo este escenario definido se realizaron las diferentes pruebas en donde, para cada uno de los escenarios propuestos el sistema de control respondió de una manera medianamente robusta garantizando un voltaje nominal estable con un error inferior al 1% y una eficiencia superior al 85%. Se concluyó que los convertidores propuestos tienen una alta eficiencia y son versátiles para su aplicación el lazo cerrado. No obstante, se recomienda la implementación de uno de los casos de estudio, lo que permitirá comprobar o refutar de manera experimental lo propuesto en la investigación. | es_ES |
dc.description.abstract | The present research aimed to analyze the performance from direct current conversion systems to direct current (DC-DC) of multi-input single-output (MISO) in closed-loop isolated and non-isolated based on classical controllers under a hybrid renewable energy production environment through design, modeling, and simulation. The research started from a review of the state of the art about these systems, product from which the design strategies proposed by the different authors were deduced; and according to this, the different study cases were raised, such as the buck converter, buck-boost converter, Flyback, and Forward converter, of these last two corresponding to the isolated architecture. The characterization was obtained from each of these cases and the sizing criteria were established under the ideal analysis methodology based on the voltage and current of the coil. However, for the analysis of non-ideal effects, modeling, and closed-loop control, the buck converter and the Flyback converter were taken as representative. Once the analysis of the converters was established, the research focused on designing and implementing the hybrid renewable energy production environment in a closed-loop in which the proposed models were going to be evaluated. Under this defined scenario, different tests were carried out where, for each of the scenarios, the control system responded in a moderately robust manner, guaranteeing a stable nominal voltage with an error of less than 1% and an efficiency greater than 85%. It was concluded that the proposed converters have high efficiency and are versatile for their closed-loop application. However. The implementation of one of the case studies is recommended, which will allow experimentally verifying or rejecting what is proposed in the research. | es_ES |
dc.language.iso | spa | es_ES |
dc.publisher | Escuela Superior Politécnica de Chimborazo | es_ES |
dc.relation.ispartofseries | UDCTFIYE;108T0444 | - |
dc.rights | info:eu-repo/semantics/openAccess | es_ES |
dc.subject | SISTEMAS DE CONVERSIÓN | es_ES |
dc.subject | CONTROL AUTOMÁTICO | es_ES |
dc.subject | ENERGÍAS RENOVABLES | es_ES |
dc.subject | ELECTRÓNICA DE POTENCIA | es_ES |
dc.subject | MAQUINAS ELÉCTRICAS | es_ES |
dc.title | Análisis del rendimiento de sistemas de conversión DC-DC MISO aislado y no aislado en lazo cerrado basado en controladores clásicos bajo un entorno de producción de energía renovable híbrida mediante el diseño, modelado y simulación. | es_ES |
dc.type | info:eu-repo/semantics/bachelorThesis | es_ES |
dc.contributor.miembrotribunal | Romero Riera, Paul Patricio | - |
dc.rights.uri | https://creativecommons.org/licenses/by-nc-sa/3.0/ec/ | es_ES |
Aparece en las colecciones: | Ingeniero en Electrónica, Control y Redes Industriales; Ingeniero/a en Electrónica y Automatización |
Ficheros en este ítem:
Fichero | Descripción | Tamaño | Formato | |
---|---|---|---|---|
108T0444.pdf | 8 MB | Adobe PDF | Visualizar/Abrir |
Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons