Por favor, use este identificador para citar o enlazar este ítem: http://dspace.espoch.edu.ec/handle/123456789/21291
Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.contributor.advisorLeón Chimbolema, José Gerardo-
dc.contributor.authorZambrano Quihuiri, Fernando René-
dc.date.accessioned2024-06-05T21:45:18Z-
dc.date.available2024-06-05T21:45:18Z-
dc.date.issued2023-08-01-
dc.identifier.citationZambrano Quihuiri, Fernando René. (2023). Diseño de lagunas de oxidación para tratamiento de aguas residuales generadas en los barrios (paraíso, san jorge, el llío y san sebastián) del cantón “chambo”. Escuela Superior Politécnica de Chimborazo. Riobambaes_ES
dc.identifier.urihttp://dspace.espoch.edu.ec/handle/123456789/21291-
dc.descriptionSe diseñó un sistema de tratamiento con base en lagunas de oxidación para aguas residuales generadas en los barrios (Paraíso, San Jorge, El Llio, San Sebastián) del Cantón “Chambo”, empleando instrumental básico para la medición de los caudales, para el punto de descarga por medio del método volumétrico, además, se recogió muestras de las aguas residuales para realizar análisis de caracterización física, química y biológica que se recogió in situ. Los resultados de los caudales tuvieron como mayor recolección del sistema de alcantarillado del agua residual con un promedio de 4.02 L/s el cual es fundamental para el diseño del sistema. La caracterización fisicoquímica así como la bilógica fue realizada en los laboratorios de calidad de agua de la Escuela Superior Politécnica de Chimborazo, mostró resultados fuera de los límites permisibles según el al acuerdo ministerial 097-A, los cuales fueron la demanda bioquímica de oxígeno con un valor de 182.75 mg/L, la demanda química de oxígeno con 388.19 mg/mL, sólidos suspendidos con 142.21 mg/L, y coliformes fecales con 7.567*106 NMP/100 mL. Se diseñó un sistema de tratamiento en la cual se basa en lagunas de oxidación para dicho tratamiento, el cual tuvo una eficiencia total de la planta del 80% tomando como base la remoción de la demanda bioquímica de oxígeno en 5 días (DBO5) solubles, para de esta manera comprobar si los resultados de la concentración son correctos verificando así que se cumpla con la normativa ambiental. Se recomienda la implementación del sistema de tratamiento por parte del municipio del cantón Chambo para mejorar la calidad del agua que se descarga en el rio Chambo.es_ES
dc.description.abstractA treatment system based on oxidation ponds was designed for wastewater generated in the neighbourhoods (Paraíso, San Jorge, El Llio, San Sebastián) of the "Chambo" Canton, using basic instruments for flow measurement, for the point discharge by volumetric method.Wastewater samples were collected to conduct in situ physical, chemical,and biological characterization analyses.The results of the flows had a more significant collection of the sewage system of residual water with an average of 4.02 L / s, which is essential for the design of the system. The physicochemical, as well as biological characterization was carried out in the water quality laboratories of the Escuela Superior Politécnica de Chimborazo.It showed results outside the permissible limits according to ministerial agreement 097-A, which were the biochemical oxygen demand with a value of 182.75 mg/L, the chemical oxygen demand of 388.19 mg/mL, suspended solids with 142.21 mg/ L, and faecal coliforms with 7,567*106 MPN/100 mL.A treatment system was designed in which it is based on oxidation lagoons for said treatment, which had a total efficiency of the plant of 80% based on the removal of the biochemical oxygen demand in 5 days (BOD₅) solubles; in this way, check if theresults of the concentration are correct, thus verifying that environmental regulations are complied with.Implementing the treatment system by the municipality of the Chambo canton is recommended to improve the quality of the water discharged into the Chambo River.es_ES
dc.language.isospaes_ES
dc.publisherEscuela Superior Politécnica de Chimborazoes_ES
dc.relation.ispartofseriesUDCTFC;236T0721-
dc.rightsinfo:eu-repo/semantics/openAccesses_ES
dc.subjectLAGUNAS DE OXIDACIÓNes_ES
dc.subjectAGUAS RESIDUALESes_ES
dc.subjectMÉTODO VOLUMÉTRICOes_ES
dc.subjectCARACTERIZACIÓN FISICOQUÍMICAes_ES
dc.subjectCARACTERIZACIÓN BILÓGICAes_ES
dc.subjectDEMANDA BIOQUÍMICA DE OXÍGENOes_ES
dc.subjectDEMANDA QUÍMICA DE OXÍGENOes_ES
dc.titleDiseño de lagunas de oxidación para tratamiento de aguas residuales generadas en los barrios (paraíso, san jorge, el llío y san sebastián) del cantón “chambo”es_ES
dc.typeinfo:eu-repo/semantics/bachelorThesises_ES
dc.contributor.miembrotribunalGonzález García, Juan Carlos-
dc.rights.urihttps://creativecommons.org/licenses/by-nc-sa/3.0/ec/es_ES
Aparece en las colecciones: Ingeniero/a en Biotecnología Ambiental; Ingeniero/a Ambiental

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
236T0721.pdf3,22 MBAdobe PDFVista previa
Visualizar/Abrir


Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons Creative Commons