Por favor, use este identificador para citar o enlazar este ítem: http://dspace.espoch.edu.ec/handle/123456789/21095
Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.contributor.advisorCoello Cabezas, Julio Rolando-
dc.contributor.authorCedeño Castro, Gabriela Betzabeth-
dc.date.accessioned2024-05-16T17:33:56Z-
dc.date.available2024-05-16T17:33:56Z-
dc.date.issued2022-07-28-
dc.identifier.citationCedeño Castro, Gabriela Betzabeth. (2022). Tratamiento químico de los lixiviados provenientes del relleno sanitario del cantón Shushufindi. Escuela Superior Politécnica de Chimborazo. Riobambaes_ES
dc.identifier.urihttp://dspace.espoch.edu.ec/handle/123456789/21095-
dc.descriptionEl presente trabajo de investigación se enfocó en la aplicación del tratamiento químico de coagulación-floculación para la clarificación de los lixiviados provenientes del relleno sanitario del Cantón Shushufindi; con el fin de disminuir la concentración de contaminantes presentes. Como referencia fueron tomados parámetros del Texto Unificado de Legislación Secundaria del Ministerio del Ambiente (TULSMA) Libro VI, Anexo I, Tabla 9, para la caracterización física – química del lixiviado. La metodología se desarrolló utilizando cuatro químicos, dos clarificantes coagulantes metálicos (Sulfato de Aluminio, y Policloruro de Aluminio) y dos orgánicos (Poliamida y Polidadmac), ocho químicos floculantes como aniónicos, catiónicos y no iónico. Se preparó soluciones al 0.1% y al 1% respectivamente. Utilizando el equipo de pruebas de jarras, combinando coagulantes en dosis de 50 a 1500 ppm; floculantes de 1 a 10 ppm y un oxidante 50 ppm. De la combinación de estos químicos, se obtuvo cuatro productos que dieron buenos resultados para este tipo de lixiviados. Siendo el producto 4 con una combinación de (50 ppm de hipoclorito de sodio, 1200 ppm de policloruro de aluminio y 2 ppm del floculante 8 (catiónico de baja carga y alto peso), el mejor producto logrando la remoción de la turbiedad en un 98,98%, en cuanto a la demanda bioquímica de oxígeno (DBQ5), se logra una reducción del 40% y de un 43,43% para la demanda química de oxígeno (DQO), en cuanto al potencial de hidrógeno se observa una variación mínima de un 2,10%. Como se puede notar la eliminación de los sólidos suspendidos es casi total, no así la presencia de la carga orgánica, por lo que esta técnica es recomendable para el tratamiento de lixiviados. Finalmente se recomienda implementar un proceso biológico como complemento del tratamiento químico de clarificación ya que ayudaría a eliminar completamente el remante de materia orgánica.es_ES
dc.description.abstractThe present research work focused on the application of the chemical treatment of coagulation- flocculation for the clarification of leachate from the sanitary landfill of Shushufindi City, in order to reduce the concentration of pollutants present. As a reference, parameters were taken from the Unified Text of Secondary Legislation of the Ministry of Environment (TULSMA) Book VI, Annex I, Table 9, for the physical-chemical characterization of the leachate. The methodology was developed using four chemicals, two metallic coagulant clarifiers (Aluminum Sulfate and Aluminum Polychloride) and two organic ones (Polyamide and Polydadmac), eight flocculant chemicals such as anionic, cationic and non-ionic. Solutions were prepared at 0.1% and 1% respectively. Using the jar test equipment, combining coagulants in doses from 50 to 1500 ppm; flocculants from 1 to 10 ppm and an oxidant 50 ppm. From the combination of these chemicals, four products were obtained that gave good results for this type of leachate. Being product 4 with a combination of (50 ppm of sodium hypochlorite, 1200 ppm of aluminum polychloride and 2 ppm of flocculant 8 (low load and high weight cationic), the best product achieving the removal of the turbidity in 98,98%, as for the biochemical oxygen demand (DBQ5), a reduction of 40% is achieved and 43.43% for the chemical oxygen demand (COD), as for the hydrogen potential a minimum variation of tm 2.10% is observed. As it can be noticed, the elimination of the suspended solids is almost total, but not the presence of the organic load, so this technique is recommended for leachate treatment. Finally, it is recommended to implement a biological process as a complement to the chemical clarification treatment, since it would help to completely eliminate the remaining organic matter.es_ES
dc.language.isospaes_ES
dc.publisherEscuela Superior Politécnica de Chimborazoes_ES
dc.relation.ispartofseriesUDCTFC;236T0678-
dc.rightsinfo:eu-repo/semantics/openAccesses_ES
dc.subjectTRATAMIENTO QUÍMICOes_ES
dc.subjectRELLENO SANITARIOes_ES
dc.subjectLIXIVIADOSes_ES
dc.subjectTEXTO UNIFICADO DE LEGISLACIÓN SECUNDARIA (TULSMA)es_ES
dc.subjectCOAGULANTEes_ES
dc.subjectCOAGULACIÓNes_ES
dc.subjectCLARIFICACIÓNes_ES
dc.titleTratamiento químico de los lixiviados provenientes del relleno sanitario del cantón Shushufindies_ES
dc.typeinfo:eu-repo/semantics/bachelorThesises_ES
dc.contributor.miembrotribunalDominguez Gaibor, Norma Isabel-
dc.rights.urihttps://creativecommons.org/licenses/by-nc-sa/3.0/ec/es_ES
Aparece en las colecciones: Ingeniero/a en Biotecnología Ambiental; Ingeniero/a Ambiental

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
236T0678.pdf3,16 MBAdobe PDFVista previa
Visualizar/Abrir


Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons Creative Commons