Por favor, use este identificador para citar o enlazar este ítem: http://dspace.espoch.edu.ec/handle/123456789/20957
Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.contributor.advisorSerrano Aguiar, Carlos Oswaldo-
dc.contributor.authorGuallo Choca, Hugo Abraham-
dc.contributor.authorGuamán Cajamarca, Jorge Antonio-
dc.date.accessioned2024-05-06T15:56:18Z-
dc.date.available2024-05-06T15:56:18Z-
dc.date.issued2023-12-07-
dc.identifier.citationGuallo Choca, Hugo Abraham; Guamán Cajamarca, Jorge Antonio. (2023). Monitoreo de la tasa de corrosión en probetas metálicas utilizando diferentes métodos de protección en la Empresa ADELCA del cantón Milagro. Escuela Superior Politécnica de Chimborazo. Riobamba.es_ES
dc.identifier.urihttp://dspace.espoch.edu.ec/handle/123456789/20957-
dc.descriptionEn el sector industrial no existen datos acerca de la velocidad de corrosión del acero estructural en un medio agresivo (cálido), por este motivo surgió la necesidad de realizar el análisis de la tasa de corrosión. Por lo tanto, el objetivo de la investigación fue establecer la estación de experimentación acerca de la tasa de corrosión en probetas metálicas con diferentes métodos de protección en la empresa ADELCA del cantón Milagro, provincia del Guayas. La metodología para la investigación fue mediante estadística descriptiva con datos obtenidos de cuatro grupos de probetas, un grupo sin método de protección y tres grupos con métodos de protección tales como el recubrimiento de zinc, el recubrimiento superficial y la protección catódica por ánodo de sacrificio; además se elaboró un contenedor capaz de soportar el electrolito utilizado (tierra) y cada grupo de probetas con su respectivo método de protección anticorrosiva. Para el análisis estadístico se utilizó el software R-Studio el cual facilitó el análisis de datos, además con relación a la velocidad de corrosión esta mostró ser variable dependiendo las condiciones a las cuáles se sometió el acero estructural, esta velocidad se volvió nula mientras que el método de protección perdure. En este contexto se concluye que la velocidad media del acero negro sin ningún tipo de protección anticorrosiva es de 0.0030647 mm/año, mientras que en el acero galvanizado se obtuvo una velocidad de 0,000398881 mm/año, el cual ayudó a identificar la duración del recubrimiento del acero estructural antes de que comience su corrosión agresiva, esto ayudará a una rápida intervención antes de que exista una gran consecuencia a causa de la corrosión.es_ES
dc.description.abstractIn the industrial sector, there is no data about the corrosion rate of structural steel in an aggressive (warm) environment; for this reason, the need arose to perform an analysis of the corrosion rate. Therefore, the objective of this research was to establish the experiment station on the corrosion rate in metal specimens with different protection methods at the ADELCA company in the Milagro canton, province of Guayas. The methodology for the research was through descriptive statistics with data obtained from four groups of specimens, one group without a protection method and three groups with protection methods such as zinc coating, surface coating, and cathodic protection by sacrificial anode. In addition, a container capable of supporting the electrolyte (earth) and each group of test tubes with their respective anti-corrosion protection method was created. The R-Studio software was used for the statistical analysis, which facilitated the data analysis. In addition, the corrosion rate was variable depending on the conditions to which the structural steel was subjected. This speed became null while the protection method lasted. In this context, it is concluded that the average speed of black steel without any anticorrosive protection is 0.0030647 mm/year. In comparison, in galvanized steel, a speed of 0.000398881 mm/year was obtained, which helped to identify the duration of the coating of the structural steel before its aggressive corrosion begins; this will help in rapid intervention before there is a significant consequence due to corrosion.es_ES
dc.language.isospaes_ES
dc.publisherEscuela Superior Politécnica de Chimborazoes_ES
dc.relation.ispartofseriesUDCTFM;25T00547-
dc.rightsinfo:eu-repo/semantics/openAccesses_ES
dc.subjectTECNOLOGÍA Y CIENCIAS DE LA INGENIERÍAes_ES
dc.subjectTASA DE CORROSIÓNes_ES
dc.subjectPROBETAS METÁLICASes_ES
dc.subjectRECUBRIMIENTO SUPERFICIALes_ES
dc.subjectPROTECCIÓN CATÓDICAes_ES
dc.subjectVELOCIDAD DE CORROSIÓNes_ES
dc.titleMonitoreo de la tasa de corrosión en probetas metálicas utilizando diferentes métodos de protección en la Empresa ADELCA del cantón Milagroes_ES
dc.typeinfo:eu-repo/semantics/bachelorThesises_ES
dc.contributor.miembrotribunalHidalgo Viteri, Luis Carlos-
dc.rights.urihttps://creativecommons.org/licenses/by-nc-sa/3.0/ec/es_ES
Aparece en las colecciones: Ingeniero de Mantenimiento; Ingeniero/a en Mantenimiento Industrial