Por favor, use este identificador para citar o enlazar este ítem:
http://dspace.espoch.edu.ec/handle/123456789/19806
Registro completo de metadatos
Campo DC | Valor | Lengua/Idioma |
---|---|---|
dc.contributor.advisor | Ormaza Hugo, Rosa Maricela | - |
dc.contributor.author | Agualzaca Caisaguano, Edgar Samuel | - |
dc.date.accessioned | 2023-09-29T20:25:11Z | - |
dc.date.available | 2023-09-29T20:25:11Z | - |
dc.date.issued | 2022-08-05 | - |
dc.identifier.citation | Agualzaca Caisaguano, Edgar Samuel. (2022). Determinación de los cambios producidos en la sangre por la radiación ionizante, mediante una simulación en GEANT4. Escuela Superior Politécnica de Chimborazo. Riobamba | es_ES |
dc.identifier.uri | http://dspace.espoch.edu.ec/handle/123456789/19806 | - |
dc.description | El presente Proyecto de Investigación tuvo como propósito desarrollar una simulación que permita la manipulación y estudio de los efectos producidos de la interacción de la sangre con la radiación ionizante, utilizadas en el diagnóstico y tratamiento de enfermedades oncológicas, neurológicas cardiovasculares. Para lo cual se desarrolló un fantoma antropomorfo con los órganos radiosensibles (cerebro, ojos, corazón, pulmón, hígado, riñones, estomago) y se especificó el sistema cardiovascular. Considerando a la pierna como órgano fuente y al coágulo de sangre como órgano blanco; se definió parámetros iniciales de la simulación para el radiofármaco Cs-137 y F-18 con actividades de 2200 curíes y 15 milicuries respectivamente de la cual se extrajo histogramas y los perfiles de dosis de profundidad. La simulación se realizó en el software Geant4 ampliamente utilizado en diversas áreas aplicadas a la física médica. Mediante los arreglos de detectores de voxeles de 1 milímetro ubicados en el órgano blanco del fantoma se determinó la dosis de radiación que llegó al coágulo de sangre. Como resultado, se obtuvo que la dosis absorbida por el coágulo de sangre de 3,85E-11 Grays (Gy) para la fuente de Cs-137 y 7,0998E-12 Gy para el F-18 respectivamente. Se concluye que el valor de la dosis absorbida por la sangre se encuentra por dejado de 0,3 Gy establecidas por la Comisión Internacional de Protección Radiológica donde se registran los cambios producidos por la radiación ionizante en la sangre. Se sugiere su aplicación en pruebas in vitro con la actividad irradiada, de modo que se pueda utilizar para el diagnóstico y tratamiento de patologías de la sangre como son la trombosis venenosa profunda y la tromboembolia pulmonar. | es_ES |
dc.description.abstract | The purpose of this research project was to develop a simulation that allows the manipulation and study of the effects produced by the interaction of blood with ionizing radiation, used in the diagnosis and treatment of oncological, neurological, and cardiovascular diseases. For this purpose, an anthropomorphic phantom was developed with the radiosensitive organs (brain, eyes, heart, lung, liver, kidneys, stomach) and the cardiovascular system was specified. Considering the leg as the source organ and the blood clot as the target organ; initial simulation parameters were defined for the radiopharmaceutical Cs-137 and F-18 with activities of 2200 curies and 15 millicuries respectively from which histograms and depth dose profiles were extracted. The simulation was performed in the Geant4 software widely used in various areas applied to medical physics. Using 1 millimeter voxel detector arrays placed on the target organ of the phantom the radiation dose to the blood clot was determined. As a result, the dose absorbed by the blood clot was 3,85E-11 Grays (Gy) for the Cs-137 source and 7,0998E-12 Gy for the F-18 respectively. It is concluded that the value of the dose absorbed by the blood is below the 0,3 Gy established by the International Commission Radiological Protection where the changes produced by ionizing radiation in the blood are recorded. Its application in in vitro tests with irradiated activity is suggested, so that it can be used for the diagnosis and treatment of blood pathologies such as deep venous thrombosis and pulmonary thromboembolism. | es_ES |
dc.language.iso | spa | es_ES |
dc.publisher | Escuela Superior Politécnica de Chimborazo | es_ES |
dc.relation.ispartofseries | UDCTFC;66T00060 | - |
dc.rights | info:eu-repo/semantics/openAccess | es_ES |
dc.subject | GEANT4 (SOTFWARE) | es_ES |
dc.subject | RADIACIÓN IONIZANTE | es_ES |
dc.subject | SANGRE | es_ES |
dc.subject | COAGULACIÓN | es_ES |
dc.subject | GLÓBULOS ROJOS | es_ES |
dc.subject | GLÓBULOS BLANCOS | es_ES |
dc.subject | PLAQUETAS | es_ES |
dc.subject | PLASMA | es_ES |
dc.title | Determinación de los cambios producidos en la sangre por la radiación ionizante, mediante una simulación en GEANT4 | es_ES |
dc.type | info:eu-repo/semantics/bachelorThesis | es_ES |
dc.contributor.miembrotribunal | Heredia Moyano, Maria Fernanda | - |
dc.rights.uri | https://creativecommons.org/licenses/by-nc-sa/3.0/ec/ | es_ES |
Aparece en las colecciones: | Físico/a |
Ficheros en este ítem:
Fichero | Descripción | Tamaño | Formato | |
---|---|---|---|---|
66T00060.pdf | 2,1 MB | Adobe PDF | Visualizar/Abrir |
Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons