Por favor, use este identificador para citar o enlazar este ítem: http://dspace.espoch.edu.ec/handle/123456789/1976
Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.contributor.advisorVillacrés Álvarez, Mario Gustavo-
dc.contributor.authorVargas Tierras, Tannia Jazmín-
dc.date.accessioned2012-07-12T19:30:23Z-
dc.date.available2012-07-12T19:30:23Z-
dc.date.issued2012-07-12T19:30:23Z-
dc.identifier.citationVargas Tierras, Tannia Jazmín. (2012). Optimización del Sistema de Tratamiento de Agua Residual de la Planta Nº 01 del Cantón Joya de los Sachas. Escuela Superior Politécnica de Chimborazo. Riobamba.es_ES
dc.identifier.citationEscuela Superior Politécnica de Chimborazoes_ES
dc.identifier.urihttp://dspace.espoch.edu.ec/handle/123456789/1976-
dc.descriptionOptimización de la Planta de Tratamiento de Agua Residual N0 01 en el Cantón La Joya de los Sachas, Provincia de Orellana. Se utilizó método analítico, determinándose variables para análisis del agua residual de entrada y salida del sistema de tratamiento, además da a conocer condiciones físicas - químicas - biológicas del agua tratada en planta. Los análisis fueron realizados en el laboratorio con equipos específicos para pH, temperatura; gravimétricos para sólidos; espectrofométricos para cloro; incubación para DBO y coliformes fecales; digestión para DQO, y materiales como: tubos de ensayo, gradilla, pipeta, vasos de precipitación y caja petri. Para el muestreo en campo del agua residual se usó botellas de vidrio y frascos estériles, guantes y mascarilla. Los resultados indican que la concentración de coliformes fecales incumplen la norma, los demás parámetros están en conformidad. Para la remoción de coliformes se implementa un sistema de desinfección con una solución de cloro de 4ppm, lográndose reducir su concentración en 99.9%. Para impedir ingreso de basura a la planta se implementó dos rejillas en serie (1.1m*0.60m); una rejilla grande con 13 barras metálicas, espesor de 1.8 cm con un espaciamiento entre ellas de 3 cm y, una rejilla pequeña de 16 barras metálicas, de espesor de 0.9cm con un espaciamiento de 2 cm. La optimización permite descargar un efluente de buena calidad hacia el río Quinchayacu, cumpliéndose con los límites máximos permisibles de descarga de agua residual a un cuerpo de agua dulce. Se recomienda a la municipalidad hacer un seguimiento de la calidad del agua tratada en el sistema para controlar el buen funcionamiento del mismo y dar mantenimiento adecuado, evitandose obstrucción y deterioro.es_ES
dc.description.abstract"Optimization of he Residual Water Plat Nº 1 in the Joya de los Sachas Camon, Orellana Province. For this investigation the analyical method was used with which the important variables for the analysis of th ile and outlet residual water of he treatment system were determined. Moreover the physical, chemical and biological conditions of the treated water at the plant were known. The analyses were carried out at the laboratory with specific equipment for the Ph, temperature, gravimetric for solids, spectrofometic for chloride, incubation for DBO and fecal coliformes, digestion or DQO and specific materials such as test tubes, small sepladder,pipete, recipittion glasses and Petri box. For the in situ sampling oe: residual water glass botles and steile Mask, gloves and a mask were used. The results show tbat the Fecal coliform concentration do not accomplish the morm; the: úlher considered parameters do accomplish it. For the coliform removal a disinfection system is implemented which requires a chloride solution or Appm and it ís possible to reduce the coliform concentration by a 99.9%. To impede the garbage entrance to the plant, wo serial grills(1.Imx0, 60m), a big grill with 13 metallic bars, 1.8 cm thick and Jem. spacing between them and a small grill with 16 metalic bars, 0.%cm thick and 2 cm spacing. The optimization is of great importance as it permi o discharge a good quality eíMuent to the Quinchayacu River, which accomplishes the maximum permisible limits or residual water discharge to a fresh water body, established in the actual Ecuadorian environmental nor, thus bencfíing the population. The population is recommended to follow up the quality of the water treated in the treatment system to control its good functioning and provide an adequate maintenance to, his way avoid obstruction and decay."es_ES
dc.language.isospaes_ES
dc.relation.ispartofseriesUDCTFC;96T00155-
dc.rightsinfo:eu-repo/semantics/openAccesses_ES
dc.subjectOPTIMIZACIÓN DE SISTEMAS DE TRAMIENTO E AGUAes_ES
dc.subjectTRATAMIENTO DE AGUAS RESIDUALESes_ES
dc.subjectSISTEMAS DE TRATAMIENTO DE AGUAS RESIDUALESes_ES
dc.subjectESTUDIO TÉCNICO - ECONÓMICOes_ES
dc.subjectANÁLISIS DE AGUAS RESIDUALESes_ES
dc.titleOptimización del Sistema de Tratamiento de Agua Residual de la Planta Nº 01 del Cantón Joya de los Sachases_ES
dc.typebachelorThesises_ES
dc.contributor.miembrotribunalChuiza Rojas, Marco Raúl; Calderon, Hugo-
dc.rights.urihttps://creativecommons.org/licenses/by-nc-sa/3.0/ec/es_ES
Aparece en las colecciones: Ingeniero/a Químico/a

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
96T00155.pdf2,73 MBAdobe PDFVista previa
Visualizar/Abrir


Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons Creative Commons