Por favor, use este identificador para citar o enlazar este ítem: http://dspace.espoch.edu.ec/handle/123456789/16999
Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.contributor.advisorOrbe Ordoñez, Jheny del Carmen-
dc.contributor.authorTenicota Pacha, Diego Patricio-
dc.date.accessioned2022-09-20T17:44:29Z-
dc.date.available2022-09-20T17:44:29Z-
dc.date.issued2021-03-17-
dc.identifier.citationTenicota Pacha, Diego Patricio. (2021). Cálculo del coeficiente de exhalación de radón de la papa, usando la técnica Electret Ion Chamber. Escuela Superior Politécnica de Chimborazo. Riobamba.es_ES
dc.identifier.urihttp://dspace.espoch.edu.ec/handle/123456789/16999-
dc.descriptionEste Trabajo de Titulación, realizado en el laboratorio de Técnicas Nucleares de la Escuela Superior Politécnica de Chimborazo extiende el uso de la técnica Electret Ion Chamber para determinar la tasa de exhalación superficial y másica de radón de cuatro diferentes variedades de papa (Pusa, Superchola, Única y Pera) cultivadas en la provincia de Bolívar. Diecinueve experimentos independientes fueron llevados a cabo, usando muestras de 72 gramos con granulometría de 3mm y 6mm. Para obtener resultados más precisos en los cálculos de exhalación superficial y másica se aplicó el factor de corrección por elevación (FCE). La tasa media de exhalación superficial y másica corregidos por el FCE muestran un valor mayor al 40% respecto a los no corregidos. Muestras de papa Superchola y Única con granulometría de 3mm presentan igual tasa media de exhalación superficial y másica, dentro de las incertidumbres (0.65 Bq por metro cuadrado por hora y 0.05 Bq por kilogramo por hora respectivamente), lo mismo ocurre para las variedades Pera y Pusa (0.45 Bq por metro cuadrado por hora y 0.03 Bq por kilogramo por hora respectivamente); sin embrago, los valores de las variedades Superchola y Única es mayor que para las variedades Pera y Pusa. Muestras de papa Superchola, Única, Pera y Pusa con granulometría de 6mm muestran la misma tasa media exhalación superficial y másica de radón (0.57 Bq por metro cuadrado por hora y 0.04 Bq por kilogramo por hora respectivamente). La granulometría de las muestras de papa influye en la tasa de exhalación superficial y másica de radón. Finalmente, con el fin de obteener un valor único de exhalación, se calculó el valor medio de las 19 medidas individuales, los resultados fueron de 0.55 Bq por metro cuadrado por hora y 0.05 Bq por kilogramo por hora respectivamente.es_ES
dc.description.abstractThis Degree Thesis, carried out at the Nuclear Techniques Laboratory of the Escuela Superior Politécnica de Chimborazo, extends the use of the Electret Ion Chamber technique to to determine the surface and mass exhalation rate of radon from four different varieties of potato (Pusa, Superchola, Única and Pera) grown in the province of Bolívar. Nineteen independent experiments were carried out, using samples of 72 grams with a particle size of granulometry of 3mm and 6mm. In order to obtain more accurate results in the calculations of surface and mass exhalation, the elevation correction factor (ECF) was applied. The average rate of and mass exhalation corrected by the ECF show a value higher than 40% compared to the uncorrected ones. Superchola and Única potato samples with a particle size of 3 mm show equal mean surface and mass exhalation rate, within the uncertainties (0.65 Bq per square metre per hour and 0.05 Bq per square metre per hour). per square metre per hour and 0.05 Bq per kilogram per hour respectively), the same is true for the Pera and Pusa varieties. (0.45 Bq per square metre per hour and 0.03 Bq per kilogramme per hour respectively); however, the values for the varieties Superchola and Única are higher than for the varieties Pera and Pusa. Potato samples of Superchola, Única, Pera and Pusa with 6 mm particle size show the same average surface and mass radon exhalation rate (0.57 Bq per metre). (0.57 Bq per square metre per hour and 0.04 Bq per kilogram per hour respectively). The granulometry of the potato samples influences on the surface and mass exhalation rate of radon. Finally, in order to obtain a single exhalation value, the mean value of the 19 individual measurements was calculated, the results were 0.55 Bq per square metre per hour and 0.05 Bq per kilogram per hour respectively.es_ES
dc.language.isospaes_ES
dc.publisherEscuela Superior Politécnica de Chimborazoes_ES
dc.relation.ispartofseriesUDCTFC;86T00116-
dc.rightsinfo:eu-repo/semantics/openAccesses_ES
dc.subjectTECNOLOGÍA Y CIENCIAS DE LA INGENIERÍAes_ES
dc.subjectBIOFÍSICAes_ES
dc.subjectTÉCNICA ELECTRET ION CHAMBERes_ES
dc.subjectCONCENTRACIÓN DE RADÓNes_ES
dc.subjectFACTOR DE CORRECCIÓN POR ELEVACIÓNes_ES
dc.subjectFONDO GAMMAes_ES
dc.subjectTASA DE EXHALACIÓN SUPERFICIALes_ES
dc.subjectTASA DE EXHALACIÓN MÁSICAes_ES
dc.titleCálculo del coeficiente de exhalación de radón de la papa, usando la técnica Electret Ion Chamberes_ES
dc.typeinfo:eu-repo/semantics/bachelorThesises_ES
dc.contributor.miembrotribunalHeredia Moyano, María Fernanda-
dc.rights.urihttps://creativecommons.org/licenses/by-nc-sa/3.0/ec/es_ES
Aparece en las colecciones: Biofísica

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
86T00116.pdf1,62 MBAdobe PDFVista previa
Visualizar/Abrir


Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons Creative Commons