dc.contributor.advisorHernández Dávila, Eduardo Segundo-
dc.contributor.authorGamarra Aucancela, Darío Manuel-
dc.contributor.authorPaca Paltán, Jorge Aníbal-
dc.date.accessioned2022-07-18T20:21:52Z-
dc.date.available2022-07-18T20:21:52Z-
dc.date.issued2022-03-16-
dc.identifier.citationGamarra Aucancela, Darío Manuel; Paca Paltán, Jorge Aníbal. (2022). Implementación de un módulo de simulación para el diagnóstico vibracional de la excentricidad estática del motor de inducción para el rotor kit del laboratorio de diagnóstico técnico y eficiencia energética. Escuela Superior Politécnica de Chimborazo. Riobamba.es_ES
dc.identifier.urihttp://dspace.espoch.edu.ec/handle/123456789/16219-
dc.descriptionEl objetivo del presente proyecto técnico, es implementar un módulo de simulación para diagnosticar fallas de excentricidad estática que se presentan en los motores de inducción. Se eligió este tipo de motor para contribuir al diagnóstico de máquinas eléctricas rotativas puesto que es muy popular en el entorno industrial. Inicialmente para la construcción del módulo se seleccionó los instrumentos y parámetros de funcionamiento de los equipos, siendo la bomba periférica el equipo principal del módulo con presencia de falla; posteriormente se realizó el diseño y modelado de los elementos constitutivos mediante el software SolidWorks Académico, como finalmente en la etapa de construcción se instaló y se ensambló cada subsistema para llegar a la etapa de operación y prueba. La metodología utilizada para el diagnóstico y detección de falla de excentricidad estática se realizó mediante la técnica del análisis espectral de vibraciones mecánicas, para ello se vio necesario simular cargas mediante presiones variables estrangulando el caudal del fluido por medio de la válvula de esfera en la línea de descarga del sistema de bombeo. Para el análisis e interpretación de resultados se recopiló datos mediante el colector de vibraciones Vibracheck ABG 200 sobre el punto rígido denominado inserto o target en el plano radial horizontal de la bomba, que conjuntamente con el software MAINTraq Predictive se logró identificar los armónicos y espectros característicos de falla; por medio de ellos se elaboró curvas para evidenciar que la excentricidad estática presenta armónicos característicos a frecuencias específicas, siendo esta el doble de la frecuencia de línea (2FL), concluyendo que los armónicos a 120 Hz permanecen constantes independientemente de la carga representando a la falla de excentricidad estática. Para corroborar que el incremento de la presión no afecta a la variable 2FL se recomienda realizar el test de correlación con un 95% de confianza.es_ES
dc.description.abstractThe objective of this technical project was to implement a simulation module to diagnose static eccentricity faults that occur in induction motors. This type of motor was chosen to help diagnose rotating electrical machines as it is very popular in the industrial environment. Initially, for the construction of the module, the instruments and operating parameters of the equipment were selected, with the peripheral pump being the main equipment of the module with the presence of a fault. Subsequently, the design and modeling of the constituent elements was carried out using the SolidWorks Academic software. Finally, in the construction stage, each subsystem was installed and assembled to reach the operation and test stage. The methodology used for the diagnosis and detection of static eccentricity failure was carried out through the technique of spectral analysis of mechanical vibrations, for which it was necessary to simulate loads through variable pressures, strangling the fluid flow through the ball valve in the line pumping system discharge. For the analysis and interpretation of results, data was collected using the Vibracheck ABG 200 vibration collector on the rigid point called insert or target in the horizontal radial plane of the pump, which together with the MAINTraq Predictive software was able to identify the harmonics and characteristic spectra of fault; by means of them, curves were elaborated to show that the static eccentricity presents characteristic harmonics at specific frequencies, this being twice the line frequency (2FL). It concludes that the harmonics at 120 Hz remain constant regardless of the load representing the static eccentricity failure. To confirm that the increase in pressure does not affect the 2FL variable, it is recommended to carry out the correlation test with 95% confidence.es_ES
dc.language.isospaes_ES
dc.publisherEscuela Superior Politécnica de Chimborazoes_ES
dc.relation.ispartofseriesUDCTFM;25T00441-
dc.rightsinfo:eu-repo/semantics/openAccesses_ES
dc.subjectTECNOLOGÍA Y CIENCIAS DE LA INGENIERÍAes_ES
dc.subjectMÓDULO DE SIMULACIÓNes_ES
dc.subjectEXCENTRICIDAD ESTÁTICAes_ES
dc.subjectANÁLISIS VIBRACIONALes_ES
dc.subjectFRECUENCIA DE LÍNEAes_ES
dc.subjectFRECUENCIA NATURALes_ES
dc.titleImplementación de un módulo de simulación para el diagnóstico vibracional de la excentricidad estática del motor de inducción para el rotor kit del laboratorio de diagnóstico técnico y eficiencia energéticaes_ES
dc.typeinfo:eu-repo/semantics/bachelorThesises_ES
dc.contributor.miembrotribunalNaranjo Vargas, Eugenia Mercedes-
dc.rights.urihttps://creativecommons.org/licenses/by-nc-sa/3.0/ec/es_ES
Aparece en las colecciones: Ingeniero de Mantenimiento; Ingeniero/a en Mantenimiento Industrial