dc.contributor.authorNoriega, Holguer-
dc.contributor.authorHerrera Pérez, Víctor-
dc.contributor.authorPacheco Cunduri, Mayra-
dc.contributor.authorGuevara Cabezas, Esteban-
dc.contributor.authorVaca Urbano, Fernando-
dc.contributor.authorOrtiz Parra, Iván-
dc.date.accessioned2022-06-10T14:22:10Z-
dc.date.available2022-06-10T14:22:10Z-
dc.date.issued2021-07-10-
dc.identifier.urihttp://dspace.espoch.edu.ec/handle/123456789/15795-
dc.descriptionEl este artículo se trabajó bajo un diseño de micro-red híbrida que incluye generación fotovoltaica y red eléctrica para realizar un análisis de estabilidad de la respuesta de la micro-red considerando escenarios de operación aislada y conectada a la red red. La metodología de análisis de estabilidad se desarrolló utilizando el software ETAP, a partir del modelado y simulación de 4 casos correspondientes a distintos escenarios de operación de la micro-red de carga concentrada de 400 kW, en los que se identificó las posibles fallas de estabilidad. Finalmente se probó y resolvió el peor tipo de falla ocurrida, determinando que el sistema fotovoltaico no influye en la estabilidad en operación aislada, adjudicando la inestabilidad a los dispositivos auxiliares de la red, y a la rapidez de respuesta de los mismos a las fallas. Se concluyó que el tiempo de despeje crítico y el ángulo de despeje crítico de la falla son cruciales para saber si un sistema de energía eléctrica podrá volver a una condición estable o volverse inestable.es_ES
dc.description.abstractIn this article, we worked under a hybrid microgrid design that includes photovoltaic generation and electrical network to perform a stability analysis of the microgrid response considering off-grid and on-grid operation scenarios. The methodology used for stability analysis was developed using the ETAP software, from the modeling and simulation of 4 cases corresponding to different operating scenarios of a 400 kW concentrated electrical load micro-grid, in which possible stability failures were identified. Finally, the worst type of failure that occurred was tested and resolved, determining that the photovoltaic system does not influence the stability in off-grid operation, assigning the instability to the auxiliary devices of the network, and to the speed of their response to the failures. It was concluded that the critical clearance time and the critical clearance angle of the fault are crucial to know if an electrical power system will be able to return to a stable condition or become unstable.es_ES
dc.language.isoengen
dc.publisherEscuela Superior Politécnica de Chimborazoes_ES
dc.rightsinfo:eu-repo/semantics/openAccesses_ES
dc.subjectESTABILIDAD DE SISTEMA DE POTENCIAes_ES
dc.subjectMICRORRED HÍBRIDAes_ES
dc.subjectDESPEJE DE FALLAes_ES
dc.subjectPROSUMERen
dc.subjectPOWER SYSTEM STABILITYe
dc.subjectHYBRID MICROGRIDen
dc.subjectETAP (SOFTWARE)en
dc.subjectFAULT CLEARANCEen
dc.titleAnálisis de estabilidad del sistema de potencia de una micro-red Híbrida para operación conectado y no-conectado a la red utilizando el software ETAP.es_ES
dc.typeinfo:eu-repo/semantics/articlees_ES
dc.rights.urihttps://creativecommons.org/licenses/by-nc-sa/3.0/ec/es_ES