Por favor, use este identificador para citar o enlazar este ítem: http://dspace.espoch.edu.ec/handle/123456789/15097
Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.contributor.advisorCaicedo Reyes, Jorge Isaías-
dc.contributor.authorTorres Gavilanes, Rodman Estuardo-
dc.contributor.authorRodríguez Capelo, Marcos David-
dc.date.accessioned2022-03-14T22:00:05Z-
dc.date.available2022-03-14T22:00:05Z-
dc.date.issued2021-03-03-
dc.identifier.citationTorres Gavilanes, Rodman Estuardo. (2021). Mantenimiento e implementación de un sistema de adquisición de datos a la máquina de ensayos mecánicos péndulo Charpy II del laboratorio de resistencia de materiales de la Facultad de Mecánica. Escuela Superior Politécnica de Chimborazo. Riobambaes_ES
dc.identifier.urihttp://dspace.espoch.edu.ec/handle/123456789/15097-
dc.descriptionLa veracidad y exactitud de los resultados de un ensayo mecánico garantizan la correcta selección de un material en base a sus propiedades mecánicas, por lo tanto, se realizó el mantenimiento e implementación de un sistema de adquisición de datos a la máquina de ensayos Péndulo de Charpy II, con fines investigativos para la Escuela de Ingeniería Mecánica de la Escuela Superior Politécnica de Chimborazo. Se utilizó el método investigativo para la recopilación de la información pertinente al desarrollo de los objetivos planteados, además de un método analítico para seleccionar el controlador más adecuado a las condiciones ambientales y didácticas que se tomaron en cuenta, siendo el seleccionado un microordenador conocido como Raspberry pi 3 B +, que en conjunto con un enconder rotativo incremental captaron y procesaron los valores de posición del martillo luego del impacto con las diferentes probetas, este valor en conjunto con las ecuaciones respectivas nos permitió determinar la energía absorbida por los diferentes materiales seleccionados, siendo estos los aceros 1040 , ASTM A36 y ASTM A304, que son los más utilizados en el mercado nacional. Además, se realizó un mantenimiento correctivo y preventivo a los diferentes elementos que componen a péndulo de Charpy , en donde se sustituyó los elementos deteriorados por el uso, y se protegió a los que se hallaron en buen estado, se creó un nuevo plan de mantenimiento preventivo en base a los nuevos requerimientos del Equipo, finalmente se logró mejorar la precisión y exactitud de la maquina al implementar un sistema digital de obtención de datos , que brindo mayor precisión con un error porcentual de 0,44%, todo esto bajo las recomendaciones de las normas ASTM E23,INEN 130, INEN 1503.es_ES
dc.description.abstractThe veracity and accuracy of the results of a mechanical test guarantee the correct selection of a material based on its mechanical properties, therefore, the maintenance and implementation of a data acquisition system was carried out on the Pendulum Charpy II testing machine for research parpases for the School of Mechanical Engineering of the Escuela Superior Politécnica de Chimborazo. The investigative method was used to compile information pertinent to the development of the proposed objectives, in addition to an analytical method to select the most appropriate controller for the environmental and educational conditions that were considered, the selected being a microcomputer known as Raspberry pi 3 B+, which together with an incremental rotary encoder captured and processed the hammer position values after impact with the different specimens. This value together with the respective equations allowed to determine the energy absorbed by the different selected materials, these being the 1040, ASTM A36 and ASTM A304 steels, which are the most widely used in the national market. In addition, corrective and preventive maintenance was carried out on the different elements that make up the Charpy pendulum, where the elements deteriorated due to use were replaced, and those that were found in good condition were protected, a new maintenance plan was created, based on the new requirements of the equipment. It was finally possible to improve the precision and accuracy of the machine by implementing a digital data collection system, which provided greater precision with a percentage error of 0.44%, all this under the recommendations of the ASTM E23, INEN 130, INEN 1503 standards.es_ES
dc.language.isospaes_ES
dc.publisherEscuela Superior Politécnica de Chimborazoes_ES
dc.relation.ispartofseriesUDCTFM;15T00755-
dc.rightsinfo:eu-repo/semantics/openAccesses_ES
dc.subjectTECNOLOGÍA Y CIENCIAS DE LA INGENIERÍAes_ES
dc.subjectMECÁNICAes_ES
dc.subjectPRECISIÓNes_ES
dc.subjectEXACTITUDes_ES
dc.subjectOBSOLENCIA TECNÓLOGICAes_ES
dc.subjectENSAYOS MECÁNICOSes_ES
dc.subjectMICROORDENADORes_ES
dc.subjectTENACIDADes_ES
dc.titleMantenimiento e implementación de un sistema de adquisición de datos a la máquina de ensayos mecánicos péndulo Charpy II del laboratorio de resistencia de materiales de la Facultad de Mecánicaes_ES
dc.typeinfo:eu-repo/semantics/bachelorThesises_ES
dc.contributor.miembrotribunalMayorga Pérez, Diego Fernando-
dc.rights.urihttps://creativecommons.org/licenses/by-nc-sa/3.0/ec/es_ES
Aparece en las colecciones: Ingeniero/a Mecánico/a

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
15T00755.pdf9,73 MBAdobe PDFVista previa
Visualizar/Abrir


Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons Creative Commons