Por favor, use este identificador para citar o enlazar este ítem: http://dspace.espoch.edu.ec/handle/123456789/15078
Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.contributor.advisorChuquin Vasco, Juan Pablo-
dc.contributor.authorMasson Arias, Christian Geovanny-
dc.contributor.authorPacheco Torres, John Fernando-
dc.date.accessioned2022-03-11T21:34:17Z-
dc.date.available2022-03-11T21:34:17Z-
dc.date.issued2020-11-30-
dc.identifier.citationChristian Geovanny, Masson Arias. (2020). Diseño, simulación e implementación de un sistema de bombeo para agua procedente de una planta de tratamiento de aguas residuales en la comunidad de San Vicente de Lacas. Escuela Superior Politécnica de Chimborazo. Riobambaes_ES
dc.identifier.urihttp://dspace.espoch.edu.ec/handle/123456789/15078-
dc.descriptionEn el presente trabajo de titulación se desarrolla el diseño, simulación e implementación de un sistema de bombeo para la comunidad San Vicente de Lacas. La misión es ayudar a la comunidad a mejorar su abastecimiento de agua de riego para el desarrollo agrícola, con el fin de mantener y aumentar la economía de la comunidad. Iniciando desde el estudio de las propiedades fisicoquímicas y microbiológicas del agua obtenida de la planta de tratamiento que resulta apta para riego, también se analiza el caudal requerido, indicando un valor mayor a 5 L/s. La tubería que se presenta en el diseño se seleccionó manteniendo la presión de trabajo y se estimó que toda la tubería sea de material PVC, debido al bajo costo y fácil adquisición en el mercado local. Posterior a esto se realizó el análisis de perdidas primarias, perdidas secundarias y altura de bombeo, para garantizar el correcto funcionamiento y abastecimiento de agua. Con esto se llega a determinar el punto de operación con la curva característica de la bomba y la curva resistiva del sistema, dando como resultados un punto de operación de caudal de 6 L/s y una altura de 33,74 m. Luego de esto se lleva a cabo una simulación en el software EPANET para corroborar los cálculos, la cual, a comparación con los datos calculados, se presenta en un error permisible, luego mediante el software ALLIEVI, se permite observar un comportamiento del fluido dentro del sistema para analizar si existe la presencia de un flujo transitorio, dando como resultado que no se presenta este fenómeno en este sistema. Se recomienda la implementación de un sistema de control automatizado, para lo cual se formuló un diagrama de flujo con los componentes electrónicos necesarios y que son llevados a un lenguaje de programación “Ladder”.es_ES
dc.description.abstractIn this research work, the design, simulation and implementation of a pumping system for the San Vicente de Lacas community is developed. The mission is to help the community to improve its irrigation water supply for agricultural development, in order to maintain and increase the community's economy. Starting from the study of the physicochemical and microbiological properties of the water obtained from the treatment plant that is suitable for irrigation, the required flow is also analyzed, indicating a value greater than 5 L/s. The pipe that is presented in the design was selected maintaining the working pressure and it was estimated that all the pipe is made of PVC material, due to the low cost and easy acquisition in the local market. After this, the analysis of primary losses, secondary losses and pumping height was carried out, to guarantee the correct operation and water supply. With this, the operating point is determined with the characteristic curve of the pump and the resistive curve of the system, resulting in a flow operating point of 6 L/s and a height of 33,74 m. After this, a simulation is carried out in the EPANET software to corroborate the calculations, which, compared to the calculated data, is presented in a permissible error, then through the ALLIEVI software, it is allowed to observe a behavior of the fluid within the system to analyze if there is the presence of a transitory flow, resulting in that this phenomenon does not occur in this system. The implementation of an automated control system is recommended, for which a flow chart was formulated with the necessary electronic components and which are taken to a "Ladder" programming language.es_ES
dc.language.isospaes_ES
dc.publisherEscuela Superior Politécnica de Chimborazoes_ES
dc.relation.ispartofseriesUDCTFM;15T00746-
dc.rightsinfo:eu-repo/semantics/openAccesses_ES
dc.subjectTECNOLOGÍA Y CIENCIAS DE LA INGENIERÍAes_ES
dc.subjectMECÁNICAes_ES
dc.subjectSISTEMA DE BOMBEOes_ES
dc.subjectMOTOBOMBAes_ES
dc.subjectPOLICLORURO DE VINIL (PVC)es_ES
dc.subjectSAN VICENTE DE LACAS (PARROQUIA)es_ES
dc.subjectRIOBAMBA (CANTÓN)es_ES
dc.subjectECUADOR (PAÍS)es_ES
dc.titleDiseño, simulación e implementación de un sistema de bombeo para agua procedente de una planta de tratamiento de aguas residuales en la comunidad de San Vicente de Lacases_ES
dc.typeinfo:eu-repo/semantics/bachelorThesises_ES
dc.contributor.miembrotribunalLópez Ortiz, Santiago Alejandro-
dc.rights.urihttps://creativecommons.org/licenses/by-nc-sa/3.0/ec/es_ES
Aparece en las colecciones: Ingeniero/a Mecánico/a

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
15T00746.pdf3,79 MBAdobe PDFVista previa
Visualizar/Abrir


Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons Creative Commons