Campo DC | Valor | Lengua/Idioma |
---|---|---|
dc.contributor.advisor | Sáez Paguay, Miguel Ángel | - |
dc.contributor.author | Bejarano Villalobos, Maribel Katherine | - |
dc.date.accessioned | 2022-03-10T20:26:34Z | - |
dc.date.available | 2022-03-10T20:26:34Z | - |
dc.date.issued | 2021-09-15 | - |
dc.identifier.citation | Bejarano Villalobos, Maribel Katherine. (2021). Simulación del efecto de la interacción de fotones de 6MV con cristalino mediante GEANT4. Escuela Superior Politécnica de Chimborazo. Riobamba. | es_ES |
dc.identifier.uri | http://dspace.espoch.edu.ec/handle/123456789/15054 | - |
dc.description | El presente trabajo de investigación tuvo como finalidad simular el efecto de la interacción de fotones de 6MV en cristalino haciendo uso del método Monte Carlo. Para ello se desarrolló la simulación en tres etapas: la primera consistió en la construcción de la geometría de un modelo aproximado de ojos con sus cristalinos ubicados a 100cm de la fuente y un modelo usual de acelerador de radioterapia de haz externo compuesto de: un blanco, un colimador primario, un filtro aplanador, una cámara de ionización y un modelo de mandíbulas para definir un tamaño de campo de 10x10 cm2 para fotones de 6MV de energía. También se crearon las geometrías de los detectores. Para la segunda etapa, se parametrizó las geometrías para declarar los detectores en el modelo de ojos y estimar los eventos y la contribución de dosis en los cristalinos simulados. En la tercera etapa, se declaró el generador de procesos físicos y la física necesaria para la simulación a través de comandos de usuario en un archivo .in de la plataforma GAMOS. Para el análisis de dosis en el cristalino se generó Histogramas Dosis - Volumen, Perfiles de dosis y valores de dosis absorbida mediante la ejecución de comandos. Los resultados mostraron que la dosis absorbida varía de acuerdo a la profundidad que alcanzan los fotones aportando pequeñas cantidades de dosis por evento y se concluye que la dosis absorbida total para el cristalino derecho e izquierdo simulados es de 0.04 mGy y 0.05 mGy respectivamente, debido a los parámetros físicos del haz de radiación. Se recomienda extender el estudio simulando situaciones clínicas reales y geometrías realistas no idealizadas. | es_ES |
dc.description.abstract | The aim of this research work was to simulate the effect of the interaction of 6MV photons on the crystalline lens using the Monte Carlo method. For this purpose, the simulation was developed in three stages: the first one consisted in the construction of the geometry of an approximate model of eyes with their crystalline lens located 100cm from the source and a usual model of an external beam radiotherapy accelerator composed of: a target, a primary collimator, a flattening filter, an ionisation chamber, and a model of jaws to define a field size of 10x10 cm2 for photons of 6MV energy. Detector geometries were also created. For the second stage, the geometries were parameterised to declare the detectors in the eye model and estimate the events and dose contribution in the simulated crystallites. In the third stage, the physical process generator and the physics required for the simulation were declared via user commands in an .in file of the GAMOS platform. For the dose analysis in the crystalline lens, Dose-Volume Histograms, Dose Profiles and absorbed dose values were generated by executing commands. The results showed that the absorbed dose varies according to the depth that the photons reach, contributing small amounts of dose per event and it is concluded that the total absorbed dose for the simulated right and left crystalline lens is 0.04 mGy and 0.05 mGy respectively, due to the physical parameters of the radiation beam. It is recommended to extend the study by simulating real clinical situations and realistic, non-idealised geometries. | es_ES |
dc.language.iso | spa | es_ES |
dc.publisher | Escuela Superior Politécnica de Chimborazo | es_ES |
dc.relation.ispartofseries | UDCTFC;86T00151 | - |
dc.rights | info:eu-repo/semantics/openAccess | es_ES |
dc.subject | CIENCIAS EXACTAS Y NATURALES | es_ES |
dc.subject | FÍSICA | es_ES |
dc.subject | MÉTODO MONTE CARLO | es_ES |
dc.subject | SIMULACIÓN | es_ES |
dc.subject | INTERACCIÓN RADIACIÓN-MATERIA | es_ES |
dc.subject | GEANT4 | es_ES |
dc.subject | PLATAFORMA GAMOS | es_ES |
dc.subject | ACELERADOR LINEAL | es_ES |
dc.title | Simulación del efecto de la interacción de fotones de 6MV con cristalino mediante GEANT4 | es_ES |
dc.type | info:eu-repo/semantics/bachelorThesis | es_ES |
dc.contributor.miembrotribunal | Cortez Bonilla, Luis Marcelo | - |
dc.rights.uri | https://creativecommons.org/licenses/by-nc-sa/3.0/ec/ | es_ES |
Aparece en las colecciones: | Biofísica |
Ficheros en este ítem:
Fichero | Descripción | Tamaño | Formato | |
---|---|---|---|---|
86T00151.pdf | 3,6 MB | Adobe PDF | Visualizar/Abrir |
Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons