Por favor, use este identificador para citar o enlazar este ítem:
http://dspace.espoch.edu.ec/handle/123456789/14755
Registro completo de metadatos
Campo DC | Valor | Lengua/Idioma |
---|---|---|
dc.contributor.advisor | Vinueza Tapia, Diego Renato | - |
dc.contributor.author | Bolaños Sánchez, Jessica Andréa | - |
dc.date.accessioned | 2022-01-12T23:00:52Z | - |
dc.date.available | 2022-01-12T23:00:52Z | - |
dc.date.issued | 2021-08-27 | - |
dc.identifier.citation | Bolaños Sánchez, Jessica Andrea (2021). Validación del proceso de limpieza y manufactura de una jalea multivitamínica, en el Laboratorio Neofármaco del Ecuador. Escuela Superior Politécnica de Chimborazo. Riobamba. | es_ES |
dc.identifier.uri | http://dspace.espoch.edu.ec/handle/123456789/14755 | - |
dc.description | El objetivo del presente trabajo fue validar el proceso de limpieza y manufactura de jalea multivitamínica, elaborada en el laboratorio Neofármaco. En la validación de limpieza se tomaron en consideración los equipos y materiales involucrados en el tren de fabricación, en los cuales se identificaron 78 puntos críticos de muestreo, así también se establecieron dos peores casos: vitamina B2 (riboflavina) y vitamina E (tocoferol); para vitaminas hidrosolubles y liposolubles respectivamente. El análisis de limpieza se realizó mediante cromatografía líquida de alta resolución (HPLC), el agua del último enjuague de los equipos y materiales se analizó por conductimetría y pH, así también se realizó el análisis microbiológico de los puntos críticos de muestreo en los cuales no se observó crecimiento microbiano. En la validación de manufactura se identificaron diferentes puntos críticos de control en el proceso de elaboración de la jalea multivitamínica, los cuales fueron muestreados en diferentes tiempos, de tres puntos: fondo, medio y final; los cuales fueron analizadas por HPLC y volumetría, de estos resultados se realizó un análisis de capacidad de proceso, mismo que demostró que el tiempo final de mezcla de la jalea multivitamínica establecido por el laboratorio es el adecuado. En la mezcla final, se realizaron todas las pruebas de control de calidad, incluido el análisis microbiológico, encontrándose este producto dentro de los parámetros establecidos por el Laboratorio Neofármaco. En conclusión, el proceso de limpieza y manufactura de la jalea multivitamínica cumple con los criterios establecidos para su validación, es necesario realizar el estudio de lotes posteriores para asegurar un proceso de limpieza y manufactura reproducible en el tiempo. | es_ES |
dc.description.abstract | The objective of this research was to validate the cleaning and manufacturing process of multivitamin jelly, elaborated in the Neodrug laboratory. In the cleaning validation, the equipment and materials involved in the manufacturing train were taken into consideration, in which 78 critical sampling points were identified, as well as two worst cases: vitamin B2 (riboflavin) and vitamin E (tocopherol); for water-soluble and fat-soluble vitamins respectively. The cleanlinessanalysis was carried out using high- performance liquid chromatography (HPLC), the water from the last rinse of the equipment and materials was analyzed by conductimetry and pH, as well as the microbiological analysis of the critical sampling points in which no microbial growth was observed. In the manufacturing validation, different critical control points were identified in the multivitamin jelly elaboration process, which were sampled at different times, from the three points: background, middle and end; which were analyzed by HPLC and volumetry, of these results a process capacity analysis was carried out, which showed that the final mixing time of the multivitamin jelly established by the laboratory is adequate. In the final mixture, all the quality control tests were carried out, including the microbiological analysis, finding this product within the parameters established by the Neodrug laboratory. In conclusion, the cleaning and manufacturing process of multivitamin jelly meets the criteria established for its validation, it is necessary to carry out the study of subsequent batches to ensure a reproducible cleaning and manufacturing process over time. | es_ES |
dc.language.iso | spa | es_ES |
dc.publisher | Escuela Superior Politécnica de Chimborazo | es_ES |
dc.relation.ispartofseries | UDCTFC;56T01003 | - |
dc.rights | info:eu-repo/semantics/openAccess | es_ES |
dc.subject | BIOQUIMICA | es_ES |
dc.subject | METODOS DE LIMPIEZA [Validación] | es_ES |
dc.subject | VALIDACIÓN DE MANUFACTURA | es_ES |
dc.subject | VITAMINA B2 (RIBOFLAVINA) | es_ES |
dc.subject | VITAMINA E (TOCOFEROL) | es_ES |
dc.subject | CROMATOGRAFÍA LÍQUIDA DE ALTA RESOLUCIÓN (HPLC) | es_ES |
dc.subject | ÍNDICE DE CAPACIDAD DEL PROCESO | es_ES |
dc.subject | ANÁLISIS MICROBIOLÓGICO | es_ES |
dc.title | Validación del proceso de limpieza y manufactura de una jalea multivitamínica, en el Laboratorio Neofármaco del Ecuador | es_ES |
dc.type | info:eu-repo/semantics/bachelorThesis | es_ES |
dc.contributor.miembrotribunal | Idrovo Novillo, Julio César | - |
dc.rights.uri | https://creativecommons.org/licenses/by-nc-sa/3.0/ec/ | es_ES |
Aparece en las colecciones: | Bioquímico/a y Farmacéutico/a |
Ficheros en este ítem:
Fichero | Descripción | Tamaño | Formato | |
---|---|---|---|---|
56T01003.pdf | 3,69 MB | Adobe PDF | Visualizar/Abrir |
Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons