Por favor, use este identificador para citar o enlazar este ítem: http://dspace.espoch.edu.ec/handle/123456789/14616
Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.contributor.advisorViteri Uzcátegui, María Rafaela-
dc.contributor.advisorGonzález García, Juan Carlos-
dc.contributor.authorEstrada Velasco, María Victoria-
dc.date.accessioned2021-09-22T17:00:18Z-
dc.date.available2021-09-22T17:00:18Z-
dc.date.issued2021-01-20-
dc.identifier.citationEstrada Velasco, María Victoria. (2021). Evaluación de la concentración de contaminantes atmosféricos en el sector del By Pass de la ciudad de Riobamba. Escuela Superior Politécnica de Chimborazo. Riobamba.es_ES
dc.identifier.urihttp://dspace.espoch.edu.ec/handle/123456789/14616-
dc.descriptionEl objetivo de la presente investigación fue evaluar la concentración de contaminantes atmosféricos en el sector del BY PASS de la ciudad de Riobamba y así verificar la calidad del aire en esta zona de gran flujo vehicular. Para el estudio se procedió a determinar la concentración de NOx considerando 36 puntos ubicados 500 metros cuadrados a la redonda del área de influencia del lugar mencionado, utilizando captadores pasivos preparados previamente en el laboratorio y colocados 2.5 m sobre el suelo en postes o lugares estratégicos. Los muestreadores pasivos aplican el proceso de difusión molecular captando NOx por medio de una solución de trietanolamina, n-butanol. El monitoreo se realizó durante un período de 4 semanas y los captadores fueron analizados por un espectrofotómetro UV para determinar su absorbancia y a través de fórmulas establecer las concentraciones de los contaminantes. Posteriormente fue establecido el flujo vehicular mediante el conteo de los transportes en 6 puntos de la zona para luego simularlo en el software PTV Vissim y con los resultados mediante mapas visualizar las zonas que abarcan la mayor concentración del NOx. Según la medición se establece que el valor máximo es de 3042.527 µg/m3 en 8 días, siendo una concentración de 380.32 µg/m3 diaria, estipulando que este contaminante sobrepasa los límites permisibles de acuerdo al MAE, 2003 donde se establece el valor para NOx es de 100 µg/m3 al año y 150 µg/m3 en 24 horas. Esto se debe a la cantidad de vehículos, locales comerciales y semáforos; además que la zona de estudio es un punto clave para el ingreso y salida de transportes hacia la ciudad de Riobamba. Se recomienda realizar monitoreos con un tiempo superior a un mes y así corroborar datos de las concentraciones del contaminante estudiado.es_ES
dc.description.abstractThe purpose of the current research was to evaluate the atmospheric pollutants concentration in the BY PASS area, Riobamba city in order to verify the air quality in this heavy traffic flow area. For this study, it was necessary to determine the NOx concentration, considering 36 points placed 500 square meters around the influence area and using passive collectors which were previously prepared in the laboratory and placed 2.5 meters above the ground in posts or strategic places. The passive samplers apply the molecular diffusion process which catches NOx through a triethanolamine, n-butanol solution. The monitoring process was carried out during a 4-week period and the collectors were analyzed with the use of a UV spectrophotometer in order to determine their absorbance and establish the pollutant concentrations through formulae. Then, the traffic flow was established through the counting of the means of transport in 6 points of the area for their further simulation in Vissim PTV software; with the results obtained through maps, it was possible to observe the areas with the highest concentration of NOx. According to the measuring, it is established that the maximum value is 3042.527 µg/m3 in 8 days with a concentration of 380.32 µg/m3 a day, determining that this pollutant exceeds the allowed limits according to MAE, which establishes the value for NOx in 100 µg/m3 a year and 150 µg/m3 in 24 hours. This is due to the number of vehicles, shops and traffic lights. In addition, the study area is a clue point for the entry and exit of transport in Riobamba city. It is recommended to monitor the area for more than a month and ratify the data related to the concentrations of the pollutant studied.es_ES
dc.language.isospaes_ES
dc.publisherEscuela Superior Politécnica De Chimborazoes_ES
dc.relation.ispartofseriesUDCTFC;236T0524-
dc.rightsinfo:eu-repo/semantics/openAccesses_ES
dc.subjectBIOTECNOLOGÍA AMBIENTALes_ES
dc.subjectCONTAMINANTES ATMOSFÉRICOSes_ES
dc.subjectÓXIDOS DE NITRÓGENO (NOx)es_ES
dc.subjectPTV VISSIM (SOFTWARE)es_ES
dc.subjectMUESTREADORES PASIVOSes_ES
dc.subjectFLUJO VEHICULARes_ES
dc.subjectSECTOR BY PASSes_ES
dc.subjectRIOBAMBA (CANTÓN)es_ES
dc.titleEvaluación de la concentración de contaminantes atmosféricos en el sector del By Pass de la ciudad de Riobamba.es_ES
dc.typeinfo:eu-repo/semantics/bachelorThesises_ES
dc.contributor.miembrotribunalGonzales García, Juan Carlos-
dc.rights.urihttps://creativecommons.org/licenses/by-nc-sa/3.0/ec/es_ES
Aparece en las colecciones: Ingeniero/a en Biotecnología Ambiental; Ingeniero/a Ambiental

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
236T0524.pdf2,89 MBAdobe PDFVista previa
Visualizar/Abrir


Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons Creative Commons