Por favor, use este identificador para citar o enlazar este ítem:
http://dspace.espoch.edu.ec/handle/123456789/14297
Registro completo de metadatos
Campo DC | Valor | Lengua/Idioma |
---|---|---|
dc.contributor.advisor | Yanchapanta Bastidas, Vilma Nohemí | - |
dc.contributor.author | Villagomez Herrera, Ximena Abigail | - |
dc.date.accessioned | 2021-01-15T18:38:14Z | - |
dc.date.available | 2021-01-15T18:38:14Z | - |
dc.date.issued | 2020-06-11 | - |
dc.identifier.citation | Villagomez Herrera, Ximena Abigail. (2020). Resolución de imágenes tomográficas mediante Matlab. Escuela Superior Politécnica de Chimborazo. Riobamba | es_ES |
dc.identifier.uri | http://dspace.espoch.edu.ec/handle/123456789/14297 | - |
dc.description | El presente trabajo de titulación tuvo como objetivo realizar una simulación computacional mediante el lenguaje de programación de Matlab para mejorar la resolución de las imágenes obtenidas en Tomografía Computarizada. Para lo cual se empleó herramientas matemáticas como el análisis matricial, uso de programas computacionales que facilitan los cálculos matemáticos y el análisis comparativo basado en la visualización grafica de los resultados. Se comprobó la eficiencia de cada Método de filtrado empleados para obtener una restauración de las imágenes distorsionadas aproximada a la real pero no en su totalidad ya que cierta parte de información no se encuentra en la imagen de prueba. El rendimiento de cada uno de los filtros empleados se demostró mediante la evaluación de las pruebas experimentales e implementación de algoritmos matemáticos donde se procesan y analizan las imágenes correspondientes a una Tomografía craneal, los resultados que se obtuvieron de la aplicación de los algoritmos computacionales en base a un análisis matemático se visualizaron en el diseño de una Interfaz Gráfica para su respectiva evaluación. Se concluye que los resultados obtenidos de la aplicación de cada del filtro propuesto son excelentes en la restauración de imagen digitales, sin embargo, el filtro Inverso mostró ser el más eficaz en la detección de altas frecuencias o variaciones bruscas de los tonos de gris y evita la pérdida de información o detalles, lo cual permite obtener imágenes libres de ruido y de excelente calidad de resolución. Por lo tanto, el filtro Inverso es una excelente elección para el tratamiento o procesamiento de imágenes Tomográficas ya que genera resultados totalmente satisfactorios en cuanto a mantener una relación entre la resolución, nitidez y calidad de imagen. Se recomienda que se realice el cálculo de la relación señal-ruido para corroborar de forma teórica la efectividad del rendimiento cuantitativo de los diversos filtros implementados. | es_ES |
dc.description.abstract | The objective of this titling work was to perform a computational simulation using the Matlab programming language to improve the resolution of the images obtained in Computed Tomography. For this, mathematical tools such as matrix analysis, the use of computer programs that facilitate mathematical calculations, and comparative analysis based on the graphic display of results were used. Verify the efficiency of each filter method used to obtain a restoration of the distorted images approximate to the real one but not in its entirety since some part of the information is not found in the test image. The performance of each of the filters used was demonstrated through the evaluation of experimental tests and the implementation of mathematical algorithms where the images corresponding to a cranial tomography are processed and analyzed, the results obtained from the application of computational algorithms in Based a mathematical analysis is visualized in the design of a Graphical Interface for its respective evaluation. It is concluded that the results obtained from the application of each application of the proposed filter are excellent in the restoration of the digital image, however, the reverse filter will be the most effective in detecting high frequencies or sudden variations in shades of gray and prevents the loss of information or details, allowing images to be obtained free of noise and with excellent resolution quality. Therefore, the Inverse filter is an excellent choice for the treatment or processing of tomographic images and that generates totally satisfactory results in terms of maintaining a relationship between resolution, sharpness and image quality. It is recommended that the calculation of the signal-to-noise ratio be performed to theoretically corroborate the determination of the quantitative performance of the various filters implemented. | es_ES |
dc.language.iso | spa | es_ES |
dc.publisher | Escuela Superior Politécnica de Chimborazo | es_ES |
dc.relation.ispartofseries | UDCTFC;86T00099 | - |
dc.rights | info:eu-repo/semantics/openAccess | es_ES |
dc.subject | TECNOLOGÍA Y CIENCIAS DE LA INGENIERÍA | es_ES |
dc.subject | BIOFÍSICA | es_ES |
dc.subject | TOMOGRAFÍA COMPUTARIZADA>, | es_ES |
dc.subject | IMÁGENES DIGITALES | es_ES |
dc.subject | TRANSFORMADA INVERSA DE FOURIER> | es_ES |
dc.subject | FILTROS ESPACIALES | es_ES |
dc.subject | MATLAB (SOFTWARE) | es_ES |
dc.subject | RESTAURACIÓN DE IMÁGENES | es_ES |
dc.title | Resolución de imágenes tomográficas mediante Matlab | es_ES |
dc.type | info:eu-repo/semantics/bachelorThesis | es_ES |
dc.contributor.miembrotribunal | Pachacama Choca, Richard Willians | - |
dc.rights.uri | https://creativecommons.org/licenses/by-nc-sa/3.0/ec/ | es_ES |
Aparece en las colecciones: | Biofísica |
Ficheros en este ítem:
Fichero | Descripción | Tamaño | Formato | |
---|---|---|---|---|
86T00099.pdf | 3,62 MB | Adobe PDF | Visualizar/Abrir |
Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons