Por favor, use este identificador para citar o enlazar este ítem: http://dspace.espoch.edu.ec/handle/123456789/13599
Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.contributor.advisorBorja Mayorga, Danielita Fernanda-
dc.contributor.authorSoria Sánchez, Katerin Liliana-
dc.date.accessioned2020-01-24T16:04:55Z-
dc.date.available2020-01-24T16:04:55Z-
dc.date.issued2019-12-17-
dc.identifier.citationSoria Sánchez, Katerin Liliana. (2019). Diseño de un sistema de tratamiento de aguas residuales en la Planta de Lácteos “San Jacinto”, ubicada en el cantón Penipe, provincia de Chimborazo. Escuela Superior Politécnica de Chimborazo. Riobamba.es_ES
dc.identifier.urihttp://dspace.espoch.edu.ec/handle/123456789/13599-
dc.descriptionSe diseñó un sistema de tratamiento de aguas residuales para la Planta Láctea “San Jacinto”, que se encuentra ubicado en la Provincia de Chimborazo en el Cantón Penipe, la misma que requiere se cumpla con la norma ambiental vigente establecida en la Tabla 8 “Límites de descarga al sistema de alcantarillado público”, Libro VI Anexo 1, Normativa de Calidad Ambiental Recurso Agua del TULSMA, publicado en el registro oficial N°387. El agua residual no cumple con los parámetros establecidos dentro de la norma, se realizó la medición del caudal, posteriormente se la analizó permitiendo identificar los siguientes parámetros fuera de los límites permisibles según la normativa antes mencionada dando como resultado Aceites y Grasas, Fosforo Total, Solidos Totales, Demanda Bioquímica de Oxigeno y Demanda Química de Oxigeno con los valores de 289 mg/L, 54,48 mg/L, 11217 mg/L, 3581 mg/L, 6881 mg/L respectivamente. Una vez obtenido las variables operacionales se procedió a dimensionar los equipos para disminuir los contaminantes medidos, se definió el diseño el cual consta de lo siguiente un sistema de rejillas con un número de barras igual a 8 dispuestas en un canal que conducirá el agua a la trampa de grasa y aceite que va a tener un largo de 1.8 m, para luego llegar a un tanque imhoff de 2,59 m de profundidad para luego pasar a un filtro anaerobio de flujo ascendente de 4 m de ancho y eras de secado de 1,4 m de largo. El mismo se validó mediante resultados finales de caracterización del efluente tratado obteniendo porcentajes de remoción en los parámetros fuera de norma de: Aceites y grasas 85,72%, Fósforo Total 78.56%, Sólidos Totales 93.84%, Demanda Bioquímica de Oxígeno 95,18% y Demanda Química de Oxígeno 96,06%. Con esto recomendamos a la planta la implementación del sistema de tratamiento de agua residual.es_ES
dc.description.abstractA wastewater treatment system was designed for the "San Jacinto" Dairy Plant, which is located in the Province of Chimborazo in Penipe municipality, which requires compliance with the current environmental standard established in Table 8 "Limits of discharge to the public sewerage system ", Book VI Annex 1, TULSMA Water Resource Environmental Quality Regulations, published in official register Nº387. Wastewater does not meet the parameters established within the standard, the flow measurement was performed, subsequently analyzed allowing the identification of the following parameters out of the permissible limits according to the aforementioned regulations resulting in Oils and Fats, Total Phosphorus, Total Solids, Biochemical Demand of Oxygen and Chemical Demand of Oxygen with the values of 289 mg/L, 54.48 mg/L, 11217 mg/L, 3581 mg/L, 6881 mg/L respectively. Once the operational variables were obtained, the equipments were sized to reduce the contaminants measured, the design was defined which consists of the following a grid system with a number of bars equal to 8 arranged in a channel that will lead the water to the grease and oil trap that will be 1.8 m long, for then to reach an imhoff tank of 2.59 m deep and then go to an anaerobic upstream filter 4 m wide and dry 1,4 m long. The same was validated by final results of characterization of the treated effluent obtaining percentages of removal in the parameters out of the norm of: Oils and fats 85.72%, Total Phosphorus 78.56%, Total Solids 93.84%, Biochemical Oxygen Demand 95,18% and Chemical Oxygen Demand 96.06%. With this we recommend to the plant the implementation of the wastewater treatment system.es_ES
dc.language.isospaes_ES
dc.publisherEscuela Superior Politécnica de Chimborazoes_ES
dc.relation.ispartofseriesUDCTFC;96T00568-
dc.rightsinfo:eu-repo/semantics/openAccesses_ES
dc.subjectINGENIERÍA Y TECNOLOGÍA QUÍMICAes_ES
dc.subjectINDUSTRIA LÁCTEAes_ES
dc.subjectTRATAMIENTO DE AGUAS RESIDUALESes_ES
dc.subjectLÁCTEOSes_ES
dc.subjectDISEÑO DE PLANTA DE TRATAMIENTOes_ES
dc.subjectPENIPE (CANTÓN)es_ES
dc.titleDiseño de un sistema de tratamiento de aguas residuales en la Planta de Lácteos “San Jacinto”, ubicada en el cantón Penipe, provincia de Chimborazo.es_ES
dc.typebachelorThesises_ES
dc.contributor.miembrotribunalZambrano Vinueza, Mayra-
dc.rights.urihttps://creativecommons.org/licenses/by-nc-sa/3.0/ec/es_ES
Aparece en las colecciones: Ingeniero/a Químico/a

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
96T00568.PDF1,6 MBAdobe PDFVista previa
Visualizar/Abrir


Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons Creative Commons