Por favor, use este identificador para citar o enlazar este ítem: http://dspace.espoch.edu.ec/handle/123456789/13248
Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.contributor.advisorTubon Usca, Gabriela Viviana-
dc.contributor.authorAllauca Yumiseba, Gisell Paola-
dc.date.accessioned2019-12-06T14:30:38Z-
dc.date.available2019-12-06T14:30:38Z-
dc.date.issued2019-11-27-
dc.identifier.citationAllauca Yumiseba, Gisell Paola. (2019). Comparación de la dosis efectiva debido a la inhalación de gas Radón (222Rn) en las unidades educativas de los distritos de educación 16D01 Pastaza – Mera - Santa Clara y 05D01 Latacunga. Escuela Superior Politécnica de Chimborazo. Riobamba.es_ES
dc.identifier.urihttp://dspace.espoch.edu.ec/handle/123456789/13248-
dc.descriptionEl presente trabajo consiste en comparar la Dosis Efectiva debido a la inhalación de gas Radón (222Rn) en las Unidades Educativas de los Distritos de Educación 16D01 Pastaza-Mera-Santa Clara y 05D01 Latacunga, este estudio se llevó a cabo en las provincias de Pastaza y Cotopaxi. Se eligió 20 Unidades Educativas de cada Distrito de Educación, tomando en cuenta la infraestructura, fecha de creación y población estudiantil. Para llevar a cabo la recolección de datos, se usó los detectores pasivos E-PERM que poseen una configuración SLT, es decir está compuesta por una cámara de ionización de corto tiempo (S) y un detector de largo tiempo (LT). En cada establecimiento se ubicó dos detectores, seleccionando el lugar de recolección, considerando parámetros como: ventilación, tipo de material de construcción y acceso público, en base a estos parámetros se denominó lugar cerrado, es decir su acceso es limitado y el otro en un lugar abierto, en la cual existe fluctuación de gente. Los detectores se dejaron en cada institución durante un período de 15 días. Los datos obtenidos en ambos Distritos de Educación nos dieron Dosis Efectivas, las cuales no sobrepasan el límite establecido de 0.1 mSv/año. Para establecer una comparación estadística entre las Dosis Efectivas se usó la prueba T de Student, la misma dio como resultado, que las Dosis Efectivas debido a la inhalación de Gas Radón obtenidas en el Distrito de Educación 16D01 Pastaza-Mera-Santa Clara son mayores que las Dosis Efectivas debido a la inhalación de Gas Radón del Distrito de Educación 05D01 Latacunga. Se recomienda capacitar al personal de las Unidades Educativas respecto a la procedencia u origen del Gas Radón (222Rn) en donde se puede concentrar y las consecuencias que, el mismo puede provocar a la salud.es_ES
dc.description.abstractThe present work consists in comparing the Effective Dose due to the inhalation of Radon gas (222Rn) in the Educational Units of the Education Districts 16D01 Pastaza-Mera-Santa Clara and 05D01 Latacunga, this study was carried out in the provinces of Pastaza and Cotopaxi. 20 Educational Units of each Education District were chosen, taking into account their infrastructure, creation date, and student population. To carry out data collection, passive E-PERM detectors that have an SLT configuration were used, that is, it is composed of a short-time ionization chamber (S) and a long-time detector (LT). In each establishment two detectors were located, selecting the place of collection, considering parameters such as: ventilation, type of construction material and public access, based on these parameters it was called a closed place, that is, its access is limited and the other in an open place, in which there is fluctuation of people. The detectors were left at each institution for a period of 15 days. The data obtained in both Education Districts gave us effective doses, which do not exceed the established limit of 0.1 mSv / year. To establish a statistical comparison between the Effective Dose, the Student's T-test was used, which resulted in the fact that the Effective Dose due to the inhalation of Radon Gas obtained in the Education District 16D01 Pastaza-Mera-Santa Clara is greater than Effective Doses due to the inhalation of Radon Gas from Education District 05D01 Latacunga. It is recommended to train the staff of the Educational Units regarding origin of Radon Gas (222Rn) where it can be concentrated and the consequences that it can cause to health.es_ES
dc.language.isospaes_ES
dc.publisherEscuela Superior Politécnica de Chimborazoes_ES
dc.relation.ispartofseriesUDCTFC;86T00081-
dc.rightsinfo:eu-repo/semantics/openAccesses_ES
dc.subjectBIOFÍSICAes_ES
dc.subjectGAS RADÓN ((222Rn)es_ES
dc.subjectDETECTORES E-PERMes_ES
dc.subjectDOSIS EFECTIVAes_ES
dc.subjectINHALACIÓNes_ES
dc.subjectUNIDADES EDUCATIVASes_ES
dc.subjectPASTAZA (PROVINCIA)es_ES
dc.subjectCOTOPAXI (PROVINCIA)es_ES
dc.titleComparación de la dosis efectiva debido a la inhalación de gas Radón (222Rn) en las unidades educativas de los distritos de educación 16D01 Pastaza – Mera - Santa Clara y 05D01 Latacunga.es_ES
dc.typebachelorThesises_ES
dc.contributor.miembrotribunalPachacama Choca, Richard Williams-
dc.rights.urihttps://creativecommons.org/licenses/by-nc-sa/3.0/ec/es_ES
Aparece en las colecciones: Biofísica

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
86T00081.PDF1,76 MBAdobe PDFVista previa
Visualizar/Abrir


Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons Creative Commons