Por favor, use este identificador para citar o enlazar este ítem: http://dspace.espoch.edu.ec/handle/123456789/11105
Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.contributor.advisorParada Rivera, Mabel Mariela-
dc.contributor.authorMorales Tixi, Marcela Maribel-
dc.date.accessioned2019-07-16T21:09:49Z-
dc.date.available2019-07-16T21:09:49Z-
dc.date.issued2019-06-27-
dc.identifier.citationMorales Tixi, Marcela Maribel. (2019). Diseño de un sistema de tratamiento de aguas residuales para la curtiduría San Jacinto de la ciudad de Ambato. Escuela Superior Politécnica de Chimborazo. Riobamba.es_ES
dc.identifier.urihttp://dspace.espoch.edu.ec/handle/123456789/11105-
dc.descriptionSe diseñó un sistema de tratamiento del agua residual para la Curtiembre San Jacinto, perteneciente a la Parroquia Picaihua Cantón Ambato provincia de Tungurahua, ya que el agua residual generada en la planta de producción es descargada directamente al alcantarillado de dicha ciudad sin ningún tipo de tratamiento previo. Primero se procedió a tomar el caudal mediante el método volumétrico durante 1 hora debido a que no existe una producción continua, se estableció un caudal promedio de 0,31 L/s para el agua residual de Pelambre y 0,18 L/s para el agua de Curtido. Se realizó un muestreo complejo, se tomó diferentes muestras directamente del bombo de producción, tanto para Pelambre como para Curtido, para llevarlo a la caracterización físico química. Observamos en el agua de Pelambre se encontraba parámetros elevados como: Demanda Bioquímica de Oxígeno (DBO5), Demanda Química de Oxígeno (DQO) y Sulfuros; en cambio en el agua de Curtido son parámetros elevados era: Demanda Bioquímica de Oxígeno (DBO5), Demanda Química de Oxígeno (DQO), Cromo Hexavalente Cr VI, Cromo Total. Posteriormente conociendo los valores iniciales y obteniendo el índice de biodegradabilidad se procedió a dar un tratamiento adecuado, el mismo que consta de un tratamiento físico químico como: coagulación-floculación y sedimentación, con lo cual obtuvimos como resultado de remoción para el agua de Pelambre: 93,51 % de sulfuros, 93,15 % de DBO5 y 94,90 % de DQO; para el proceso de Curtido se obtuvo 51,96 % de DBO5, 59,68 % de DQO, 94,11 % de Cromo Hexavalente y 99,40 % de Cromo Total. Alcanzándose así la disminución de los parámetros que exige el TULSMA, Tabla 8: Normas Generales para descarga de efluentes al sistema de alcantarillado, entonces podemos decir que el sistema de tratamiento de aguas residuales es apto para lograr una descarga de agua tratada al alcantarillado sin ningún problema.es_ES
dc.description.abstractA wastewater treatment system was designed for San Jacinto Tannery, belonging to the Picaihua Canton Ambato province of Tungurahua province, since the wastewater generated in the production plant is discharged directly to the sewer system or said city without any prior treatment. First proceeded to take the flow through the volumetric method for 1 hour because there is no continuous production, established an average flow rate or 0.31 L/s for wastewater from Pelambre and 0.18 L/s for water of Tanning A complex sampling was carried out, different samples were taken directly from the production drum, both for Pelambre and for Tanning, to take it to the physical and chemical characterization. We observed in the water or Pelambre there were high parameters such as; Biochemical Oxygen Demand (BOD5), Chemical Oxygen Demand (COD) and Sulphides; instead, in the tanning water, high parameters were: Biochemical Oxygen Demand (BOD5), Chemical Oxygen Demand (COD), Hexavalent Chromium CrVI, Total Chromium, Subsequently, knowing the initial values and obtaining the biodegradability index, we proceeded to give an adequate treatment, which consists of a physical chemical treatment such as: coagulation and sedimentation, with which we obtained as a result of removal for the Pelambre water: 93.51% of sulfides, 93,15% of BOD and 94,90% of COD; For the Tanning process, we observed 51,96% of BOD5,59,68% OF cod, 94,11% of Total Chromium. Reaching this way decrease of the parameters that TULSMA demands, Table 8: General Norms for discharge of effluents to the system of sewerage, than we can say that the system of treatment of residual waters is apt to achieve a discharge of treated water to racking without any problem.es_ES
dc.language.isospaes_ES
dc.publisherEscuela Superior Politécnica de Chimborazoes_ES
dc.relation.ispartofseriesUDCTFC;96T00546-
dc.rightsinfo:eu-repo/semantics/openAccesses_ES
dc.subjectINGENIERÍA Y TECNOLOGÍA QUÍMICAes_ES
dc.subjectDISEÑO DE LA PLANTA DE TRATAMIENTOes_ES
dc.subjectAGUAS RESIDUALESes_ES
dc.subjectDESCARGA ALCANTARILLADOes_ES
dc.subjectCURTIEMBREes_ES
dc.subjectPICAIHUA (PARROQUIA)es_ES
dc.subjectTUNGURAHUA (PROVINCIA)es_ES
dc.titleDiseño de un sistema de tratamiento de aguas residuales para la curtiduría San Jacinto de la ciudad de Ambato.es_ES
dc.typebachelorThesises_ES
dc.contributor.miembrotribunalZambrano Vinueza, Mayra Paola-
dc.rights.urihttps://creativecommons.org/licenses/by-nc-sa/3.0/ec/es_ES
Aparece en las colecciones: Ingeniero/a Químico/a

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
96T00546.pdf3,97 MBAdobe PDFVista previa
Visualizar/Abrir


Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons Creative Commons