Por favor, use este identificador para citar o enlazar este ítem: http://dspace.espoch.edu.ec/handle/123456789/11023
Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.contributor.advisorCalderón, Segundo Hugo-
dc.contributor.authorCuenca Ulloa, Kerly Marilyn-
dc.date.accessioned2019-07-05T20:18:49Z-
dc.date.available2019-07-05T20:18:49Z-
dc.date.issued2019-02-19-
dc.identifier.citationCuenca Ulloa, Kerly Marilyn. (2019). Diseño de un sistema de tratamiento para lixiviados recolectados en el Relleno Sanitario del cantón Lago Agrio, provincia de Sucumbíos. Escuela Superior Politécnica de Chimborazo. Riobamba.es_ES
dc.identifier.urihttp://dspace.espoch.edu.ec/handle/123456789/11023-
dc.descriptionLa presente investigación tuvo como objetivo diseñar un sistema de tratamiento para lixiviados recolectados en el relleno sanitario del Cantón Lago Agrio, Provincia de Sucumbíos, para lo cual la investigación se realizó en dos etapas; la primera, la toma de muestras y la segunda, las pruebas experimentales que se efectuaron en el Laboratorio de Calidad del Agua de la Facultad de Ciencias de la ESPOCH. En la caracterización inicial de los lixiviados se obtuvieron los siguientes parámetros fuera de norma: DBO, DQO, sólidos totales, sólidos suspendidos totales, cobre, fósforo total, cloruros, nitrógeno amoniacal, nitrógeno total y coliformes fecales. Se calculó el índice de biodegradabilidad obteniendo un valor de 0,4; lo que indica que el lixiviado a tratar es de naturaleza biodegradable, por tal razón se aplica un sistema de tratamiento combinado, cuya propuesta es: vertedero rectangular, cribado, aireación, coagulación y sedimentación, degradación biológica y espesamiento de lodos. Se realizaron pruebas de tratabilidad y el test de jarras, para determinar la dosis óptima de coagulante y el pH óptimo de coagulación, siendo: 0,1 ppm de PAC y 6 de pH. Para la degradación biológica, se aplicaron microorganismos eficientes en una concentración de 5 % de melaza, 5% de EM•1 en estado latente y 90 % de agua, para su activación. De esta solución, se utilizó una relación de 1:1000, es decir, que por cada 1000 mL de lixiviado a tratar se agregó 1 mL de EM•1 activado, en el biorreactor aerobio. Para el dimensionamiento de los equipos, fue necesario establecer el pico de producción de lixiviados, cuyo valor fue de 2,22 L/s de caudal de diseño. Con el diseño del sistema de tratamiento propuesto se obtuvo una eficiencia de porcentaje de remoción del 87 %, lo que indica que el tratamiento es fiable para su construcción.es_ES
dc.description.abstractThe objective of the following investigation was to design a treatment system for the landfill leachate of Lago Agrio canton, Sucumbíos province. Aiming to this, the investigation was carried out in two stages: first, sample collection, second, the experimental tests carried out in Water Quality Laboratory of the Science Faculty in ESPOCH. In the initial characterization of leachates, the following parameters out of the normal range were found: BOD₅ (Biological Oxygen Demand-five days), COD (Chemical Oxygen Demand), total solids, total suspended solids, copper, total phosphorous, chlorides, ammoniacal nitrogen, total nitrogen and fecal coliforms. The result obtained after calculating the biodegradability index was 0,4; which means that the leachate to be treated has a biodegradable nature. For this reason, a combined treatment system is applied, which consists of: rectangular landfill, sieving, aeration, coagulation and sedimentation, biological degradation and sludge thickening. Several treatability tests and a jar test were carried out to determine the optimum coagulant dosage and the optimal coagulant pH, obtaining the following results: 0,1 ppm OCD and 6 of pH. For biological degradation, efficient microorganisms with a 5 % molasses concentration were used, as well as, 5 % of EM.1 in dormant state and 90% of water of its activation. A relation of 1 to 1000 of this combination was used, so for each 1000 ml of leachate to be treated, 1 ml of EM.1 activated was added to the aerobic bioreactor. In order to get the right equipment’s dimensions, it was necessary to stablish the leachate production peak, which was 2,22 L/s of flowrate design. By using this proposed treatment system design, an efficiency removal percentage of 87% was obtained, which means that the treatment is reliable for its construction.es_ES
dc.language.isospaes_ES
dc.publisherEscuela Superior Politécnica de Chimborazoes_ES
dc.relation.ispartofseriesUDCTFC;96T00532-
dc.rightsinfo:eu-repo/semantics/openAccesses_ES
dc.subjectINGENIERÍA Y TECNOLOGÍA QUÍMICAes_ES
dc.subjectDISEÑO DE PLANTA DE TRATAMIENTOes_ES
dc.subjectLIXIVIADOSes_ES
dc.subjectPORCENTAJE DE REMOCIÓNes_ES
dc.subjectMICROORGANISMOS EFICIENTESes_ES
dc.subjectCÁLCULOS DE INGENIERÍAes_ES
dc.subjectRELLENO SANITARIOes_ES
dc.subjectSUCUMBÍOS (PROVINCIA)es_ES
dc.titleDiseño de un sistema de tratamiento para lixiviados recolectados en el Relleno Sanitario del cantón Lago Agrio, provincia de Sucumbíos.es_ES
dc.typebachelorThesises_ES
dc.contributor.miembrotribunalZambrano Vinueza, Mayra-
dc.rights.urihttps://creativecommons.org/licenses/by-nc-sa/3.0/ec/es_ES
Aparece en las colecciones: Ingeniero/a Químico/a

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
96T00532.pdf2,34 MBAdobe PDFVista previa
Visualizar/Abrir


Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons Creative Commons